Technical
Information
TI 178C/07/en
No. 50088968
Areas of application
• pH/Redox measurements in the
chemical industry, for example for
− production of synthetic materials and
dyes,
− production of pesticides and
fertilisers;
• pH/Redox measurements in the
petrochemical industry, for example for
− separation of oil and waste water,
− treatment of condensates;
• pH measurements in the
pharmaceutical and cosmetic
industries, for example for
− production of soap,
− production of proteins,
− lipolysis;
• pH/Redox measurements in power
plants and waste incinerating plants,
for example for
−monitoring of cooling water,
− scrubbing of exhaust gases;
• pH/Redox measurements in extractive
metallurgy and metal processing
Benefits at a glance
• Simple installation and removal of the
electrode holder due to the bayonet
mounting method
• Good sealing, even in media
containing solid particles, due to the
bayonet mounting method
• Suitable for use at high pressures and
temperatures (up to 10 bar and
max. 150 °C)
• Immersion length from 500 to 2500 mm
• Integrated potential matching pin
made of Hastelloy C4 or tantalum
• Reduced condensation due to an
active-breathing Goretex filter
• Three mounting positions for pH,
Redox and temperature sensors plus
a cleaning head
• Spray and ultrasonic cleaning can be
retrofitted easily
• Flexible connection to the process by
means of various flanges (DIN, ANSI, JIS)
Immersion Assembly for
pH and Redox Sensors
DipFit P CPA 140
Immersion assembly with flange connection for
demanding processes.
Sensor holder with bayonet lock
Hauser+Endress
Nothing beats know-how
Quality made by
Endress+Hauser
ISO 9001
Stainless steel version
2
Stainless steel version Flange
DN 80
PN 16
ANSI 3"
150 lbs
JIS
10K 80A
D 200 190,5 185
∅ k 160 152,4 150
d2 18 19 19
b 20 23,8 18
a 63,5 63,5 63,5
Screws M 16 M 16 M 16
d2
D
∅ k
b
a
∅ 63,5
22
2108
Im
m
e
rs
io
n
le
ng
th
25
A A
Section A-A
∅ 69
TZ2.CDR
Bayonet mounting
20
1
2
3
4
5
6
7
Dimensions of the
stainless steel
assembly
DipFit P CPA 140
1 Assembly head
2 Cable gland Pg 13.5
3 Screw-in lifting eyes
4 Fixed flange
5 Electrode holder
6 Shock-protection
studs (stainless
steel 1.4401)
7 Goretex filter
Dimensions of fixed
flange
3
PVDF version
Bottom view of electrode holder with one electrode
installed and potential matching pin
Top view of the electrode holder with one electrode
installed
4
PVDF version
TZ3.CDR
Bayonet mounting
AA
Section A-A
Im
m
e
rs
io
n
le
ng
th
25
∅ 63,5
10
8
∅ 74
∅ 125
∅ 75
1
2
3
4
5
6
7
Dimensions of the
PVDF assembly
DipFit P CPA 140
1 Assembly head
2 Cable gland Pg 13.5
3 Loose flange
4 Electrode holder
6 Shock-protection studs
7 Goretex filter
d2
D
∅ k
b
a
Dimensions of
loose flange
Flange
DN 80
PN 16
ANSI 3"
150 lbs
JIS
10K 80A
D 200 200 185
∅ k 160 152 150
d2 18 19 19
b 22 22 18
a 110 110 110
Screws M 16 M 16 M 16
5
Accessories
KCl reservoir
• for supplying liquid filled pH electro-
des with KCl electrolyte
• maximum effective volume 200 ml
• available with wall-mounting bracket or
• direct mounting on assembly without
further securement
22
0
∅ 20
25
60
70
∅ 87
∅ 72
1
2
3
4
5
6
PA140-01.CDR
KCl reservoir CPY 7:
1 Valve
2 Dummy plug;
reference electrode
position
3 Dummy plug;
manometer position
4 Filling mark
5 Securing nut for
electrolyte vessel
6 Hose coupling
KCl reservoir mounted on top of the assembly CPA 140
6
Pressure / temperature
diagram
Note
The operating limits of the entire
system are determined by the operating
limits of the individual components
used (assembly, sensors, cables,
accessories, etc.)!
Technical data
General data Manufacturer Endress+Hauser
Designation DipFit P CPA 140
Installation Immersion length 500 ... 2500 mm
Electrode length 120 mm
Number of mounting positions in sensor
holder
3 cable glands Pg 13.5
Required installation cross-section DN 80
Cable gland 2 cable gland Pg 16; 1 cable glands Pg 13.5
Mounting A Without flange
B Flange DN 80 PN 16
D Flange ANSI 3", 150 lbs
E Flange JIS 10K 80A
Weight PVDF (500 mm / 2500 mm) Approx. 2.5 kg / approx. 3.0 kg
Stainless steel 1.4404 (500 mm / 2500 mm) Approx. 8.0 kg / approx. 12.0 kg
Materials in contact with medium Immersion tube PVDF / stainless steel 1.4404
O rings EPDM / Viton / Chemraz / Fluoraz
Sensor holder
Sensor holder PVDF / stainless steel 1.4404
Potential matching pin Hastelloy C4 / tantalum
Shock-protection studs PVDF / 1.4401
Dummy plugs PEEK
Materials not in contact with medium Protective cap PP-GF 20
Protective cover for KCl reservoir Stainless steel 1.4571
Screw-in lifting eyes Stainless steel 1.4301
Operating data Operating pressure
PVDF version Max. 6 bar (at 20 °C)
Stainless steel 1.4404 version Max. 10 bar
Operating temperature
PVDF version 0 ... +120 °C
Stainless steel 1.4404 version -15 ... +150 °C (EPDM 140 °C)
Subject to modifications.
200
2
4
6
8
10
40 60 80 100 120 140 160
Temperature in °C
Pe
rm
iss
ib
le
pr
es
su
re
in
ba
r
Stainless steel 1.4404
PVDF
PT-DIAGR.CDR
7
How to order
Accessories O-ring sets
− EPDM Order No. 50089296
− Viton Order No. 50089297
− Chemraz Order No. 50089298
− Fluoraz Order No. 50089299
TI 178C/07/en/09.98
Printed in Germany / DT / CV5 (50088968)
Hauser+Endress
Nothing beats know-how
Assembly/PAL material
21 PVDF / PAL: Hastelloy C4
22 PVDF / PAL: tantalum
30 Stainless steel 1.4404
Immersion length
1 500 mm
2 1000 mm
3 1500 mm
4 2000 mm
5 2500 mm
Process connection
A Without flange
B Flange DN 80 PN 16
D Flange ANSI 3"
E Flange JIS 10K 80A
Gasket material
1 EPDM
2 Viton
3 Chemraz
4 Fluoraz
Features
10 Basic version
30 Test certificate to EN 10204-3.1B
CPA 140- complete order code
Immersion assembly DipFit P CPA 140
Endress+Hauser GmbH+Co.
- Instruments International -
P.O. Box 2222
D-79574 Weil am Rhein
Tel. (07621) 975 - 02
Fax (07621) 975345
本文档为【德国E+H分析仪表:PH ORP支架 Dipfit P CPA140】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑,
图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。