1
www.dewetron.com
DEWE-2600 series
Experience the power of synchronous acquisition and
analysis of vastly different signals! The extreme flexibility of
the new DEWE-2600 allows to connect all kind of analog
signals, digital I/Os, counters, CAN-bus or GPS and even
video – all synchronized! One system clock controls the
whole instrument, either generated internally or from external
sources like GPS-CLOCK or IrIG-CLOCK.
The DEWE-2600 portable instrument can be configured to
be a very powerful recorder, a FFT analyzer, a power ana-
lyzer, a combustion analyzer or a transient recorder. That´s
already unique - but you even can use a combination of
these instruments running at the same time on one machine.
The ingenious driver and software design are the base for
this outstanding power and the clever modular mechanical
design lets the ultimate flexible instrument come true. The
incomparable DEWE-OrION data acquisition cards and the
accurate DAQP and MDAQ modules guarantee measure-
ments with highest precision even in harsh environments.
Be free to turn your DEWE-2600 to any kind of instrument
you need today and by upgrading the features over time
according to your future demands.
Key Features
easy to use, intuitive DEWESoft user interface
high accuracy, 16 or 24 bit resolution
fast sampling, 100 kS/s up to 1MS/s per channel
fast data streaming up to 80 MB/s to hard disk
up to 64 simultaneous analog input
up to 96 synchronous digital input
up to 24 synchronous counter input
up to 8 synchronous CAN bus interfaces
up to 4 synchronous video cameras
AC or DC or battery powered
Online Information
www.dewetron.com
Portable PC Instruments
A u t o m o t i v e
E n e r g y & P o w e r A n a l y s i s
A e r o s p a c e
Tr a n s p o r t a t i o n
G e n e r a l Te s t & M e a s u r e m e n t
A
u
TO
M
O
TIvE
D
E
W
E
-2600 S
E
r
IE
S
Preliminary
www.dewetron.com2
DEWE-2600 Series: Battery Powered Instruments
Input specifications DEWE-2600 DEWE-2601 DEWE-2602
Slots for DAQ or PAD modules 16 - 16
Available panel space 2 x 2U 1 x 4U and 1x 4.5 U 2 x 2U
MDAQ input channels - up to 64 up to 32
Main system 1)
Total PCI-slots 2 full / 2 half length 4 full / 3 half length 2 full / 2 half length
Hard disk
Data throughput
Power supply
Display
Processor
RAM
Ethernet
USB interfaces
RS-232 interface
Storage drive
Operating system
Dimensions (W x D x H)
Weight typ. 14.5 kg (32 lb.)
Environmental specifications
Operating temperature
Storage temperature
Humidity
Vibration
Shock
1) Please find current specifications in the latest price list
2) Depends on the system configuration. Examples:
15" TFT display, 1024 x 768 pixel (optional touch screen)
• DEWE-2600 with 4 x DEWE-ORION-1624-200 + 2x DEWE-CAM01 could store 85 MB/s
• DEWE-2601 with 6x DEWE-ORION-1616-500 could stream 80 MB/s to the harddisk
Intel® Core™2 Duo 2 GHz
1 GB (optional up to 3 GB)
2 x 1 Gbit LAN
4
1
Internal DVD +/-RW burner
-20 to +60° C
300 GB (optional flash disk up to 128 GB)
typ. 80 MB/s 2)
100 to 240 VAC
(optional DC or battery powered)
EN 60068-2-27
Microsoft® WINDOWS® XP Professional
409 x 245 x 291 mm (16.1 x 9.6 x 11.5 in.)
0 to +50° C (0 to +45° C with option 2600-PS-BAT installed)
10 to 80 % non cond., 5 to 95 % rel. humidity
EN 60068-2-6, EN 60721-3-2 class 2M2
DEWE-260x system options
Option Description
2600-PS-BAT
DEWE-DCDC-24-300-ISO External DC/DC converter with isolation, 9 to 36 VDC input range, 24 VDC output, 300 W
BAT-95WH Lithium-Ion battery, 14.4 V, 95 Wh, max. 8 A
BAT-CHARGER Desktop battery charger, incl. external AC adaptor
2600-DC-12V Power supply 12 VDC, incl. external AC adaptor DEWE-POW-12-350
2600-DC-24V Power supply 24 VDC, incl. external AC adaptor DEWE-POW-24-350
RAM-1024-3072 upgrade to 3GB RAM
DISP-15-TOUCH 15" touch-screen (requires one USB interface)
HDD-300-SSD-128 upgrade to 128 GB flash disk (replaces standard hard disk), no moving parts, max. data throughput 25 MB/s
Battery power supply with UPS function, 18 to 24 VDC non-isolated input, incl. external AC adaptor, DEWE-POW-24-350
3 slots for hot-swappable batteries, 2 batteries for appr. 2 hours operation included
DEWE-2600
Highest performed
portable instrument
Most flexible signal input
Completely modular design
Fully battery powered (option)
Optional isolated
DC power supply:
DEWE-DCDC-24-300-ISO
Standard accessory
AC power supply:
DEWE-POW-24-350
Optional battery power supply
2600-PS-BAT
This option turns your DEWE-2600 into a
fully battery powered instrument. The hot-
swappable batteries guarantee continuous
operation without an external power source.
The instrument can be operated for up to 3
hours with 3 batteries (BAT-95WH) installed.
Since this time depends a lot on the system
configuration a DEWESoft plugin shows the
battery status directly in the software. Also
alarm conditions can be set and the battery
parameters can be displayed as additional
measurement channels.
A
u
TO
M
O
TI
vE
D
E
W
E
-2
60
0
S
E
r
IE
S
Preliminary
3
Automotive • DEWE-2600
… for easy hard disk
replacement. In case of
service the hard disk can
quickly be replaced. using
the system recovery DvD
your instrument is back to
work in very short time
... ensures longer lifetime
of backlight and less
power consumption
... for investment safety.
Latest technology makes
future PC upgrades
easier and cheaper
... for convenient
mounting of the
instru ment inside
the car (2600-CSMK)
System architecture at a glance
... it´s all about DEWE-ORION and system clock
Soft
DEWE
Analog
Inputs
DEWE-
Camera
CAN
Counter
Inputs
Digital
Inputs
Digital
Outputs
int.
Clock
ext.
Clock
GPS
USB
INDUStrIAl-PC
Sensor
ChASSIS
SOftWArE
other system
in NEt config.
IrIG Clock
GPS Clock
External clock and
timing device
DEWE-OrION card
Position information
eg. motion sensor
Software synchronisation
Sensor
supply
Signal
conditioning
DAQ or MDAQ
module
Customized
Sensor Supply
µP
Technical details
removable HDD ... TFT with LED backlights ... Mini-ITX mainboard ...
Car seat
mounting kit
A
u
TO
M
O
TIvE
D
E
W
E
-2600 S
E
r
IE
S
Preliminary
www.dewetron.com4
ADC-clock
Counter input
Ideal counting
ORION-counter
Standard counter
Software interpolation
Counter input features
Encoder
DEWETrON has advanced the state-
of-the-art in counter/encoder inputs in
our data acquisition systems, improv-
ing yet again our OrION-counters.
The key advancement is that our
counters are PHASE SYNCHrONIZED.
referring to the diagram, you can see
that a standard counter is always a
sample behind. With software interpo-
lation you can get closer, but only with
DEWETrON’s advanced time shifting
technology are both the phase and
amplitude fully corrected!
Tacho
Gearthooth, CDM
Gearthooth, TrG, CDM and TrG
Gearthooth with missing teeth
Gearthooth with double teeth
Linear encoder
Linear pulse sensor
Basic counting
Gated counting
Period frequency
Two pulse edge separation
up/down counting
Period, pulse width,
frequency, duty cycle
RPM-Measurement
Length-measurement
Waveform Timing
Event Counting
A
u
TO
M
O
TI
vE
D
E
W
E
-2
60
0
S
E
r
IE
S
Preliminary
5
Automotive • DEWE-2600
0.5 u
0.5 u
0.5 u
1 u
1 u
2 u
1.5 u
2 u
1.5 u
4 u 4.5 u
1.5 u
2 u
2 u
0.5 u
0.5 u
0.5 u
1 u
1 u
Configuration guide DEWE-2600
Power supply for PNA-A100
current clamps
Combustion analyzer input
Analog outputCounter input with digital input
0.5u-AOuT-BNC-2
1u-AOuT-BNC-4
1u-AOuT-BNC-8
0.5u-AMPFLEX-POWEr-8
0.5u-AMPFLEX-POWEr-4
1.5u-OrION-DIO-PANEL-1
Standard panel for DEWE-2600-CA Analog input - DAQ modules
Configuration guide DEWE-2601
Options
Options
MDAQ panels
MDAQ panels
Limited use
(no 1.5 u MDAQ
panel in this area)
Counter input with digital input
1.5u-OrION-DIO-PANEL-1
Power supply for PNA-A100
current clamps
Analog output
Analog input - MDAQ modules
0.5u-AOuT-BNC-2
1u-AOuT-BNC-4
1u-AOuT-BNC-8
0.5u-AMPFLEX-POWEr-8
0.5u-AMPFLEX-POWEr-4
0.5 u
Analog input - MDAQ modules
A
u
TO
M
O
TIvE
D
E
W
E
-2600 S
E
r
IE
S
Preliminary
www.dewetron.com6
1.5 u
2 u
1.5 u
2 u
2 u
0.5 u
0.5 u
0.5 u
1 u
1 u
Analog input - DAQ modules
Configuration guide DEWE-2602
OptionsMDAQ panels
Counter input with digital input
1.5u-OrION-DIO-PANEL-1
Power supply for PNA-A100
current clamps
Analog output
0.5u-AOuT-BNC-2
1u-AOuT-BNC-4
1u-AOuT-BNC-8
0.5u-AMPFLEX-POWEr-8
0.5u-AMPFLEX-POWEr-4
Channel Expansion
Channel Expansions
System specifications DEWE 30-16 DEWE-30-32 DEWE-30-48 DEWE-31-16 DEWE-31-32
DAQ / PAD amplifier slots 16 32 48 - -
MDAQ amplifier input
channels - - -
up to 16
(BNC and/or DSUB)
up to 32
(BNC and/or DSUB)
A/D converter
Power supply
115 / 230 VAC
50 / 60 Hz
115 / 230 VAC
50 / 60 Hz
115 / 230 VAC
50 / 60 Hz
Directly from DEWE-
ORION-16xx series board
115 / 230 VAC
50 / 60 Hz
Dimensions (W x D x H) 435 x 133 x 245 mm 435 x 223 x 245 mm 408 x 340 x 200 mm 208 x 95 x 108 mm 435 x 133 x 245 mm
17.1 x 5.2 x 9.6 in. 17.1 x 8.8 x 9.6 in. 16.1 x 13.4 x 7.9 in. 8.2 x 3.7 x 4.3 in. 17.1 x 5.2 x 9.6 in.
Weight 4 kg (9 lbs) 7 kg (15 Ibs) 11 kg (24 Ibs) 1.6 kg (3.5 Ibs) 4 kg (9 Ibs)
DEWE-ORION-16xx in main system
Channel expansion by analog cable
A very popular way of expanding the analog
inputs is to install more DEWE-OrION cards
into the instrument and connect external signal
conditioning amplifiers via analog cables. Each
DEWE-2600 instrument has some spare PCI-
slots which can be used to install additional
DEWE-OrION cards. Select a suitable
external DEWE-30 or DEWE-31 series signal
conditioning rack, the required amplifiers and
directly connect the analog outputs to the
DEWE-OrION cards by analog signal cables.
user tip: The standard analog cable length is
2 m but these can be as long as 15 m.
DEWE-31-12
DEWE-OrION card
in main system
AC (optional DC)
power supply PO
WEr
SuPP
LY
A
NA
LOG
SIGNALS
You can select between expansion by:
Analog cable
PCI expansion
Expansion via Ethernet
Analog input - MDAQ modules
A
u
TO
M
O
TI
vE
D
E
W
E
-2
60
0
S
E
r
IE
S
Preliminary
7
Automotive • DEWE-2600
System specifications DEWE-50-PCI-32 DEWE-50-PCI-64 DEWE-51-PCI-64 DEWE-51-PCI-128 DEWE-52-PCI-3216
DAQ / PAD amplifier slots 32 64 - - 16
MDAQ amplifier input channels - - 64 128 up to 32
Internal PCI slots 4 7 4 13 4
Power supply 115 / 230 VAC
50 / 60 Hz
115 / 230 VAC
50 / 60 Hz
115 / 230 VAC
50 / 60 Hz
115 / 230 VAC
50 / 60 Hz
115 / 230 VAC
50 / 60 Hz
Dimensions (W x D x H) 435 x 287 x 223 mm 408 x 287 x 410 mm 435 x 287 x 178 mm 408 x 287 x 267 mm 435 x 287 x 223 mm
(17.1 x 11.3 x 8.8 in.) (16.1 x 11.3 x 16.1 in.) (17.1 x 11.3 x 7.0 in.) (16.0 x 11.3 x 10.5 in.) (17.1 x 11.3 x 8.8 in.)
Weight 10 kg (22 Ibs) 15 kg (33 Ibs) 6 kg (13 Ibs) 9 kg (20 Ibs) 9 kg (20 Ibs)
DEWE-5x-PCI Series: ADC Racks
0.000 ms
DEWE-2600
DEWE-2600
DEWE-2600
DEWE-2600
GPS-CLOCK
GPS-CLOCK
PCI expansion
Expansion via Ethernet
The PCI expansion is an alternative especially if high channel count is
needed. When using an expansion only one PCI slot is occupied in the
DEWE-2600 instrument by a PCI-HOST-CArD. The DEWE-50, DEWE-51
and DEWE-52 ADC racks can be connected by a 1m PCI cable. The
DEWE-OrION cards are installed inside the DEWE-5x unit and you
simply have to select the suitable signal amplifiers for your needs.
Important notice: The DEWE-2600 and the DEWE-5x must be equipped
with OrION-SYNC option.
user tip: with an additional ECArD-34 or 54 the DEWE-5x also can
be used as an independent system in combination with a laptop
computer.
The NET expansion is a fantastic way to combine two or more DEWE-2600 instruments to one multichannel
system. Each instrument must have installed hardware option OrION-SYNC and software option DEWESoft-NET.
Synchronization of all units is required too. There are two ways of synchronization: First is a simple cable connection
for distances up to 200 m, second one is GPS- or IrIG-CLOCK which is useful for long distances when a cable
connection is not possible. DEWESoft-NET software offers full remote setup, online data transfer up to the limit of the
network connection and offline data transfer between
the instruments.
user tip: The NET expansion allows multiple usages
of the PC power and fast storing capability. Multiple
decentralized hard disks offer almost no limit for fast
data storing.
DEWE-52-PCI-3216
DEWE-2600
PCI HOSTSYNC
AC (optional DC)
power supply
ETHErNET
ETHErN
ET
SYNC
SYNC
SYNC
A
u
TO
M
O
TIvE
D
E
W
E
-2600 S
E
r
IE
S
Preliminary
www.dewetron.com8
V
V
V
V
V
DAQ Series Modules
Single channel
High bandwidth - for dynamic signals
Isolation
Analog signal output (±5 v)
Exchangeable
Fits into DEWETrON systems
with built-in DAQ rack or
Pure signal conditioning solution in
conjunction with DEWE-30 series racks
Module Input type Ranges TEDS
Bandwidth (BW),
Filters (LP = lowpass,
HP = highpass)
Isolation (ISO),
Overvoltage
protection (OP)
DAQP-HV High voltage ±20, ±50, ±100 V - BW: 300 kHz ISO: 1.8 kVRMS
±200, ±400, ±800, ±1400 V LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
DAQP-DMM High voltage ±10, ±40, ±100 V - BW: 20/30 kHz ISO: 1.5 kVRMS
±200, ±400, ±1000 V LP: 10, 100 Hz, 1, 3,
20/30 kHz
DAQP-LV Voltage, current with external ±10, ±20, ±50 mV ■ BW: 300 kHz ISO: up to
shunt ±100, ±200, ±500 mV LP: 10, 30, 100, 300 Hz 1 kVRMS
±1, ±2.5, ±5, ±10, ±25, ±50 V 1, 3, 10, 30, 100, 300 kHz OP: 350 VDC
ICP® via MSI-V-ACC ±10, ±20, ±50, ±100, ±200 mV
±500 mV, ±1, ±2.5, ±5, ±10 V
Pt100, Pt200, Pt500, Pt1000, -200° C to 1000° C and
Pt2000 and resistance via 0 to 6.5 kOhm
MSI-V-RTD
DAQP-V Voltage ±0.01, ±0.1, ±1, ±5, ±10, ±50 V - BW: 50 kHz ISO: up to
Current with external shunt LP: 10, 100 Hz, 1, 10, 1 kVRMS
50 kHz OP: ±500 VDC or
300 VRMS
DAQN-AIN Voltage ±10 V (1:1 input) - - OP: < ±500 V
(jumper
selectable)
DAQP-LA-SC Current ±0.1, 0.3, 1, 3 A - BW: 300 kHz ISO: 1.4 kVRMS
Note: 5 ARMS continuous ± 10 A peak, ± 30 A peak LP: 10, 30, 100, 300 Hz
max. 5 ARMS contin. current 1, 3, 10, 30, 100, 300 kHz
DAQP-LA-B Current ±2, 6, 20 mA - BW: 300 kHz ISO: 1.4 kVRMS
Note: typ. 20 mA application ± 60 mA, 200 mA, 0.6 A LP: 10, 30, 100, 300 Hz
max 0.6 A 1, 3, 10, 30, 100, 300 kHz
DAQP-BRIDGE-A Strain gage, bridge sensors ±1, ±2, ±5, ±10, ±20, ±50 mV/V - BW: 20 kHz ISO: 350 VDC
(@ 5 VDC) LP: 10, 100 Hz, 1, 5, 20 kHz OP: ±10 VDC
Potentiometric sensors 200 Ω - 10 kΩ
Thermocouple via MSI-BR-TH-x full range of TC type
DAQP-BRIDGE-B Strain gage, bridge sensors ±0.1, ±0.2, ±0.5, ±1, ±2, ■ 1) BW: 200 kHz OP: ±10 VDC
±5, ±10, ±20, ±50, ±100 mV/V LP: 10, 30, 100, 300 Hz,
(@ 5 VDC) 1, 3, 10, 30, 100, 200 kHz
Potentiometric sensors 200 Ω - 10 kΩ
Thermocouple via MSI-BR-TH-x full range of TC type
DAQP-CFB AC bridge, strain gage Bridge: 0.1 to 1000 mV/V - BW: DC to 2.3 kHz OP: ±10 VDC
Inductive: 5 to 1000 mV/V
LP: 10, 30, 100, 300 Hz,
1 kHz
Inductive sensors, LVDT Voltage: 0.2 to 1000 mVRMS
1) TEDS support for DAQP-BRIDGE-B revision 2 only ■ = standard
Voltage & current measurement
High voltage measurement
Bridge / strain gage and carrier frequency amplifier
A
u
TO
M
O
TI
vE
D
E
W
E
-2
60
0
S
E
r
IE
S
Preliminary
9
Automotive • DEWE-2600
OUT
Module Input type Ranges TEDS
Bandwidth (BW),
Filters (LP = lowpass,
HP = highpass)
Isolation (ISO),
Overvoltage
protection (OP)
DAQP-ACC-A ICP® sensors ±50, ±166, ±500 mV, ±1.66, ±5 V - BW: 0.5 Hz to 300 kHz -
(Gain: 1, 3, 10, 30, 100) LP: 1, 10, 100, 300 kHz
HP: 0.5 Hz, 5 Hz
DAQP-CHARGE-A ICP® sensors, charge sensors Charge: 5, 50, 500 pC - BW: 0.1 Hz to 50 kHz -
5000, 50000 pC LP: 100 Hz, 1, 3, 10, 50 kHz
ICP®: ±5, ±50, ±500 mV, ±5 V HP: 0.1 Hz, 1 Hz, 10 Hz
(0, 20, 40, 60 dB)
DAQP-CHARGE-B Charge sensors ±100, ±500, ±2 000, - BW: DC to 100 kHz ISO: 350 VDC
±10 000, ±40 000, LP: 10, 30, 100, 300 Hz,
Note: selectable time constant ±200 000, ±1 000 000 pC 1, 3, 10, 30, 100 kHz
for static sensors HP: DC, 0.001 Hz to 0.5 Hz
DAQN-THERM-x Thermocouple K and J type, various ranges - BW: 4 Hz ISO: 1 kVRMS
Note: internal CJC
DAQN-RTD-x Thermoresistors Pt100, various ranges - BW: 10 Hz -
DAQP-FREQ-A Frequency 100 Hz, 1, 5, 20, 100, 200 kHz - BW: according to range ISO: 350 VDC
LP: 100 Hz,
1, 5, 20, 100, 200 kHz
DAQN-V-OUT Voltage output 1:1 output module with isolation - BW: 400 Hz ISO: 240 VDC
Input voltage: ±10 V
Output voltage: ±10 V
Voltage output module
Frequency measurement
Temperature measurement
Charge / ICP® measurement
Note: selectable integration and
double integration
BNC to Microdot adapter
(included as a standard with
DAQP-CHArGE-A modules)
CONN-DSuB-9:
Screw terminal adapter
for all modules with 9-pin
DSuB connector
Isolated high-voltage ampli-
fier: DAQP-Hv module
BNC to banana and banana
to BNC adaptors
ADAP-D9M-BNCF:
DSuB to BNC adapter
for DAQP-v series and
DAQP-FrEQ modules
A
u
TO
M
O
TIvE
D
E
W
E
-2600 S
E
r
IE
S
Preliminary
www.dewetron.com10
V
V
V
V
MDAQ Series Amplifiers
Multi channel
Small form factor for high channel density
Cost effective
High bandwidth up to 300 kHz
SUB Modules for MDAQ-BASE-x
Module # CH Input type Input ranges TEDS Bandwidth (BW),Highpass filters (HP) Excitation
MDAQ-SUB-STG-D 8 * Strain-gage (Full-, half and quarter- ■ BW: 30 kHz 0 to 12 VDC
Connector: DB-9 bridge, incl. shunt calibration)
for strain gage application:
* Voltage up to ±10 V: 15 ranges from ±2.5 mV to ±10 V
* ICP via MSI-BR-ACC: 7 ranges from ±0.25 mV to ±10 V
* Voltage up to 200 V via MSI-BR-V-200: 6 ranges from ±10 to ±200 V
* Thermocouple via MSI-BR-TH-x: full range of TC type
* Pt100, Pt200, Pt500, Pt1000, Pt2000 -200 °C to 1000 °C
and resistance via MSI-BR-RTD: and 0 to 6.5 kOhm
MDAQ-SUB-BRIDGE-D 8 * Strain-gage (Full-, and half bridge) ■ BW: 30 kHz +15 VDC and
Connector: DB-9 for strain gage sensors: HP: 0.16 Hz 0 to 12 VDC
* Voltage up to ±10 V: 15 ranges from ±2.5 mV to ±10 V
* ICP, via MSI-BR-ACC: 7 ranges from ±0.25 mV to ±10 V
* Voltage up to 200 V via MSI-BR-V-200: 6 ranges from ±10 to ±200 V
* Thermocouple via MSI-BR-TH-x: full range of TC type
* Pt100, Pt200, Pt500, Pt1000, Pt2000 -200 °C to 1000 °C
and resistance via MSI-BR-RTD: and 0 to 6.5 kOhm
MDAQ-SUB-V-200-D 8 * Voltage up to ±200 V: 13 ranges from ±0.125 to ±200 V ■ BW: 300 kHz ±15 VDC and
Connector: DB-9 * ICP, via MSI-V-ACC: 7 ranges from ±0.25 mV to ±10 V 0 to 12 VDC
* Pt100, Pt200, Pt500, Pt1000, Pt2000 -200 °C to 1000 °C
and resistance via MSI-V-RTD: and 0 to 6.5 kOhm
Note:
MDAQ-SUB-V-200-BNC 8 * Voltage up to ±200 V: 13 ranges from ±0.125 to ±200 V - BW: 300 kHz -
Connector: BNC
Note:
MDAQ-SUB-ACC-BNC 8 * ICP® or voltage up to ±10 V: 8 ranges from ±125 mV to ±10 V ■ BW: 300 kHz 4 / 8 mA
Connector: BNC HP: 3.4 Hz
MDAQ-SUB-ACC-BNC-S1 ■ BW: 300 kHz 4 / 8 mA
0,16 Hz for structural and modal analysis, human body vibration measurement HP: 0.16 Hz
(rest same as MDAQ-SUB-ACC-BNC)
MDAQ-SUB-ACC-A-BNC 8 * ICP® or voltage up to ±10 V: 8 ranges from ±125 mV to ±10 V ■ BW: 300 kHz 4 / 8 mA
Connector: BNC HP: 0.16 Hz, 3.4 Hz
Single-ended input and two HP filters
MDAQ-SUB-ACC-A-MD 8 * ICP® or voltage up to ±10 V: 8 ranges from ±125 mV to ±10 V ■ BW: 300 kHz 4 / 8 mA
Connector: Microdot HP: 0.16 Hz, 3.4 Hz
Option: test signal input for all channels
Single-ended input, two HP filters and sensor failure detection
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
for safety reasons, max. 120 V DC or 50 V AC are allowed at this connector
for safety reasons, max. 120 V DC or 50 V AC are allowed at this connector
Single-ended or
本文档为【dewe-2600_de_d081101e】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑,
图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。