首页 ABB电动门说明书解读

ABB电动门说明书解读

举报
开通vip

ABB电动门说明书解读ABB电动门说明书解读 Power Electronic Units for Field Installation 给现场装置供电使之能够工作 EAN823, EBN853, EBN861 (Contrac) EAN823, EBN853, EBN861 (Contrac) For the Control of Contrac Actuators of the PME, LME, RHD or RSD Series PME, LME, RHD or RSD系列的Contrac激励的控制 Content 目录 ...

ABB电动门说明书解读
ABB电动门 说明 关于失联党员情况说明岗位说明总经理岗位说明书会计岗位说明书行政主管岗位说明书 书解读 Power Electronic Units for Field Installation 给现场装置供电使之能够工作 EAN823, EBN853, EBN861 (Contrac) EAN823, EBN853, EBN861 (Contrac) For the Control of Contrac Actuators of the PME, LME, RHD or RSD Series PME, LME, RHD or RSD系列的Contrac激励的控制 Content 目录 1设备说明„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„2 2 应用„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„3 3 概要„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„3 3.1 正确用法„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„3 3.2 安全和预防„„„„„„„„„„„„„„„„„„„„„„„„„„„„„3 4 存放 4.1 长期存放„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„3 5 交货设置„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„3 6 汇编 6.1 EAN823 / EBN853„„„„„„„„„„„„„„„„„„„„„„„„„„4 6.2 EBN861„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„5 7 技术参数 7.1 一般的„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„, 7.2 EAN823的电流消耗„„„„„„„„„„„„„„„„„„„„„„„„„, 7.3 EBN853的电流消耗„„„„„„„„„„„„„„„„„„„„„„„„„, 7.4 EBN861的电流消耗„„„„„„„„„„„„„„„„„„„„„„„„„, 7.5 保险丝„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„, 8 装备 8.1 准备电„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„, 8.2 EAB823 / EBN853的装备„„„„„„„„„„„„„„„„„„„„„„„8 8.3 EBN861的装备„„„„„„„„„„„„„„„„„„„„„„„„„„„8 9 电路接线 9.1 EAN823 / EBN853 / EBN861( 标准 excel标准偏差excel标准偏差函数exl标准差函数国标检验抽样标准表免费下载红头文件格式标准下载 的)„„„„„„„„„„„„„„„„„„9 9.2 EAN823 / EBN853 / EBN861(现场总线数据处理)„„„„„„„„„„„„, 9.3 电缆套管„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„,, 9.4 输入 / 输出信号„„„„„„„„„„„„„„„„„„„„„„„„„„„10 9.5 插头接线 „„„„„„„„„„„„„„„„„„„„„„„„„„„„„„11 13 结构 13.1 控制面板的结构(联接控制协议)„„„„„„„„„„„„„„„„„„„12 13.2 调节器所用的程序„„„„„„„„„„„„„„„„„„„„„„„„„„13 13.3 控制面板的功能和信号„„„„„„„„„„„„„„„„„„„„„„„„13 14 警告 / 故障 14.1 解说„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„15 14.2 警告摘要„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„15 14.3 故障摘要„„„„„„„„„„„„„„„„„„„„„„„„„„„„„„16 15 故障及处理方法„„„„„„„„„„„„„„„„„„„„„„„„„„„„„17 Legend Danger Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury Warning Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury or serious property damage. Caution Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage. Important Indicates useful hints or other special informati on which, if not observed, could lead to a decline in operating convenience or affect the functionality. 1.Device Identification 设备验证 1.1 General 概述 The ID labels of the power electronics are located both 设备名牌在本体(电源部分) 标注 带电 位于底部两边 on the base (power supply) and on the cover (electronics (电源) 在盖子上面(电 和盖子封面上。 and software memory) of the unit. As the base and cover 和存储软件) 个体 底部和封面 are considered as separate assemblies, they may have 考虑过的 单独的装配 他们可以有 本体和盖面单独生产然后装配, different serial numbers (F. no.). 不同的编号 它们可以有不同的编号。 1.2ID Label on the Base 1.2本体标签 1 Elektronik / Electronics Type: .... 1 Elektronik / Electronics 类型 2 B-Nr./No. ...... NL 2 B-Nr./No. ...... NL 3 U = 190...260 V ... Jahr/Year 3 4 f = 50/60 Hz ? 5% P = max. ..... W 5 t = ..................?C IP 66 CE 6 Ext. Sicherung / Fuse ....... 6 /保险丝 Made in Germany 德国制造 Automation 自动控制 D-32425 Minden 1电源类型 1.Electronics type 2 设备编号/非标准的翻译号码 2.Device no./ No. of non-standard 3允许电源电压范围/生产日期 version 4 额定频率/最大输入电源 3.Permissible supply voltage range / Year 5 允许的工作环境温度/防护等级 of manufacture 6 关于保险丝的信息 4.Permissible frequency range / Max. power input 5.Permissible ambient temperature / Protection class 6.Information on external fuse 1.3盖子上的铭牌 介绍软件的描述 1.3 ID Labels on the Cover ID Label for Software Description 1 Für / For Antrieb / Actuator Typ / Type. . . . . . . . 2 Nennwerte / Rated values M=....... .......?/s 3 F-Nr. / No.: . . . . . . . . . . . . . . . . . . . . . . 4 NL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SW Version . . . . . . . . . . . . . . . . . . . . . 6 1 Associated actuator type 2 Rated values for torque / force / speed 3Fabrication No. 4 No. of non-standard version 5 Actuator firmware release 1相关的型号 1 Associated actuator type 2 额定转距/推力/速度 2 Rated values for torque / force / speed 3 设备编号 3 Fabrication No. 4 非标准的翻译号码 4 No. of non-standard version 5 固件版本 5 Actuator firmware release 2 运用 2.Application 用的只是actuator技术 Use this instruction only together with the actuator instruction. 3 概要 3.General 3.1 正确用法 3.1 Proper Use EAN823, EBN853 and EBN861的电源是模仿Power electronics models EAN823, EBN853 and EBN861 are to be used exlusively for actuator PME120, LME 620, RSD... or RHD... 系列的控制电,不要把他们用在其他的用途。triggering elektrical actuators of the PME120, 另外,伤害自己、伤害他人或者损坏设备运LME 620, RSD... or RHD... series. Do not use 行可靠性的危险容易发生 them for any other purpose. Otherwise, a hazard of personal injury or of damage to or impairment of the operational reliability of the device may arise. 3.2安全和防范 3.2 Safety and Precautions 未被授权的人接近带电设备时,要采取必要When mounting the electronics in areas which 的防护措施。 may be accessed by unauthorized persons, ——只有经过专门培训、被认可的人员可以take the required protective measures. 设置和调整电动部分,可以接线。 - Only qualified specialists who have been trained for these tasks are authorized to mount and adjust the electronics, and to make the electrical connection. ——工作的时候应该始终遵守适合当地情况- When working on the electronics always 的、能有效预防事故的规章,该规章是关于observe the locally valid accident prevention 建筑物安装技术方面的。 regulations and the regulations concerning the construction of technical installations. ——切断电源,确保工作时不可能触电。 - Switch-off the voltage supply; make sure that unintentional switching on is not possible ——确保切断电源不会影响工厂的运行。 - Make sure that cutting off the voltage supply does not affect the plant process ——切断电源时应考虑来自决定性控制元素- Consider restoring process forces from the 在恢复过程中的影响。 final control element when cutting off the voltage 4 存放 4.Storage 设备如果存放在潮湿或容易碰撞的环境The devices may be stored under moist and 里,则寿命会很短。保护设备不能被腐蚀。aggressive condition for a short time. The 无论如何,必须避免直接暴露在雨里、雪里、equipment is 等等。 protected against external corrosive influences. However, direct exposure to rain, snow, etc. must be avoided 接线盒里可能会受潮。所以,用干燥剂确保Condensation may occur in the terminal box. 它大约150天不潮湿。 Therefore, it is protected by a desiccant, which ensures sufficient protection for approximately 150 干燥剂在90摄氏度时4个小时内可以再生。 days. The desiccant can be regenerated at a temperature of 90? C within 4 h. 电机试运前必须拿走干燥剂 The desiccant must be removed prior to commissioning the electronics. 4.1 长期保存 4.1 Long-time Storage 如果你想要保存或者运输本设备很长的时If you intend to store or transport the device 间,我们推荐把它包在塑胶片内,并放入干for a longer time, we recommend to wrap it 燥剂。定期检查,即使干燥剂仍然起着作用。 in plastic foil and add desiccant. Regularly check if the desiccant is still active. 5.Delivery settings 移交细则 0/100%内的动作 用额定转距保持关闭状态 配置功能 线性; 输入 :4 ... 20 mA 功能 远程位置调节器,参数 输出 4 ... 20 mA 数字输入 数据输入 跳闸 手动/自动 DI 2 / DI 3 manual control +/- 手动控制 Digital outputs: DO 1 ready to operate, DO 2/3 end position signalling 数字输出 准备好操作 决定发信号的位置 Range :Not adjusted (to be adjusted during commissioning) 范围 不调整(在试车期间调整) he configuration of your actuator may differ from the standard configuration specified above. 从标准的清单上看你actuator的配置可以不同 It can be called up for display using a notebook / PC and the related configuration program. 它可以 用笔记本/个人电脑陈列配置的表 not with fieldbus communication. 不要野外通讯 6.Assemblies 装配 Power electronics EAN823, EBN853 and EBN861 consist of 2 parts each, one containing the connecting units (EAN823 and EBN853) and the transformer, the other containing the electronics and the local control panel (LCP) for local operation and adjustment of the actuator. EAN823, EBN853 and EBN861的电源由两个相互独立的部分组成,一部分包含接头 (EAN823 and EBN853)和变压器,另一部分包含就地控制面板用来现场操作和调试。 图片1:EAN823的电动部分 图片2:EBN853的电动部分 1 taphole for cable glands 2 cover for connection chamber 3 connection housing 4 electronic hod 5 cover for local control panel 1 穿线孔 2 接线盒 3 固定部分 4 电箱 5 就地控制面板 接线盒 电源保险 电缆接头 信号端子 接保险和加 热器的端子 电机端子 主保险 穿线孔 总电源接线 端子 图3 :EAN823 / EBN853的接线盒 The standard scope of delivery considers tapholes covered with srew-in plugs. Adapters for PG or NPT cable glands are available on request. 按标准交货时传闲空应该塞上。配备合适的接头是很有用的。 就地控制面板 盖用螺钉 连接螺钉 变压器和电源 连接螺钉 盖用螺钉 电器部分盖子 电机 电机主电缆电源接线端刹车 信号接线入子 线端子 口 信号电 缆入口 7.技术资料 7.1 概要 EAN823 EBN853 EBN861 工作电压 115 V AC (94 V ... 130 V) or 230 V AC (190 V... 260 230 V AC (190 V ... 260 V) ; V); 47.5 ... 63 Hz; 1Ph 47.5 ... 63 Hz; 1Ph 保险 16A;迟延熔断 35A保险16A熔断 模拟量输入 0 / 4 ... 20 mA; 电阻 50 Ohm 模拟量输出 0 / 4 ... 20 mA,屏蔽信号 ; 最大负载电阻500 Ohm 数字量输入 合适的 0:-3V ... + 5 V 或者打开, 屏蔽信号 合适的1:+12 V ...+ 35 V, 屏蔽信号 数字量输出 输出电压继电器, 最大 60 V, 150 mA 数字量信号通讯 RS 232 为了试运和维修,可以选择FSK / HART(R) 或者 PROFIBUSDP 设置默认值 定 0/100%开度:保持关闭的额定转距 函数关系:线性; setpoint = positioning value 1) 输入:4 ... 20 mA 作用:远程位置调节器, 参数: 1) 输出 (真实值):4 ... 20 mA 数字量输入:DI 1手自动切换 1) v.v., DI 2 / DI 3 手动控制 +/- 数字量输出:DO 1 准备运转, DO2/3 结束信号定位 个别设置 看资料 68-2.40 或者承索 防护等级 Ip66 湿度 小于等于95% 每年检查(允许湿度) 工作环境温度 -25? C ... +55? C 装备定位 固定在竖直钢板上,电缆管在左侧 固定在竖直钢板上,电 缆管在底部 清漆 环氧树脂(RAL 9005, 黑色) 连接电缆 最大 2 m... 30 m 最大2 m... 100 m 负载 大约10 kg 大约11kg 大约42kg 工作台 1 PROFIBUS DP通讯不了 7.2 Current Consumption of EAN823 当前通用EAN823 each around 各自周围 7.5 Fuses 保险丝 Electronic 保险类型 安装地点 U = 115 V U = 230 V 1) unit EAN823 外部保险 外部 16 A, 慢 主保险 接线盒内 6.3 A, 慢 3.15 A, 慢 模拟量信号输入 接线盒内 40 mA; 快 防潮加热器 接线盒内 2 A; 慢 EBN853 外部保险 外部 16 A, slow 主保险 接线盒内 12.5 A, slow 10 A, slow 模拟量信号输入 接线盒内 40 mA; fast 刹车保险、 动力板 0.315 A, 中间时间间隔 中间电路保险 动力板 10 A, 极快 防潮加热器 接线盒内 2 A; slow EBN861 外部保险 外部 35 A fuse -- 16 A 安全 熔断 刹车保险 功率板上 0.315 A, -- 中间有时 间间隔 中间电路保险 功率板上 15 A, 中间有 时间间隔 The 35 A fuse and the thermal safety cutout (16 A) are included in the scope of delivery. They ensure safe operation for the special swiching conditions of power electronics EBN861. Note that the cable cross-sectional area between the fuse and the electronics must be at least 2.5 . 35A保险和安全熔断保险(16A)是包含在交货范围内的。它们确保EBN861安全运行的专用保险。 注意:保险与电路的连接处必须保证至少2.5平方毫米。 7.5.1 External fuses for EBN861 Apart from the internal fuses (see also 7.5), the EBN861 power electronic unit requires two additional external fuses, which are supplied separately to the unit. 7.5.1 EBN861的外部保险 部分保险是国产的(同样是7.5),EBN861 电源需要两个外部保险,用来替换。 外部保险 外部熔断保险 8.Mounting Install the electronics close to the actuator. The connection is made via a 24-pin connector (additional 10-pin connector if heater is used) on the actuator side and screw terminals on the electronics side. The electronics are provided with the appropriate metric cable holes (see Figures 1 to 3 for the assignment). 8 设备 安装actuator的闭合电路。线路经过actuator侧面的一个24pin连接器(如果用加热器另外 还有10pin) ,用螺丝钉线固定在接线端子上。用合适的穿线孔(看形状1到3)。 8.1 Preparing the electronics - Make sure that disconnection on site is possible. - Shield all signal cables and the motor cable between the actuator and the electronics - The shield of the connection cable between the electronics and the actuator must be applied to both housings. 8.1 预备送电 ——确保没有可能的危险 ——保护控制部分和电路部分之间所有信号线和电机线 ——控制和电路之间接线的保护事项连接必须交给用户。 8.2 Mounting of EAN823 / EBN853 Disconnect the electronics and the actuator prior to all installation and service works. - Fasten the unit to the vertical mounting plate, using screws of property class 8.8 (tensile strength 800N/mm; yield strength 640 N/mm ) - Make sure that there is enough spacing for mounting, and that the unit can be easily accessed - Make sure that the cable holes are oriented to the left - Remove the cover of the connection chamber (2) - Insert the cables through the cable glands and connect them according to the wiring diagram. - Use appropriate cable glands to ensure a water-tight installation - Check if the cable is connected properly; then close the connection chamber cover. Adjust as described in section 9. 8.2 EAN823 / EBN853的装备 所有的安装和维修工作之前先断电。 ——将设备在竖直钢板上固定紧,用特制的8.8的螺丝钉(张力是800牛每平方毫米,收缩 力是640牛每平方毫米) ——确保有足够的间隔,方便走近设备 ——确保穿线孔在左边 ——取掉接线盒的盖子 ——将电缆穿过电缆管进入接线盒,按照接线图接线 ——使用合适的电缆管,以确保装置不漏水。 ——接线完后检查核对,无误后安好接线盒盖子 调试说明在第九章 9.Electrical connection Each actuator requires a Contrac electronic unit. Proper actuator operation requires an actuator specific software loaded in the associated electronic unit. Compare the data labels on both, electronic unit and actuator, in order to ensure a correct hardware and software assignment. The electrical connection is done with a plug at the actuator and with screw terminals at the electronic unit. 9 电气接线 每种装置要求不同的接线。特有的操作需要一个特殊的软件来连接电和设备。双方面比较数 据,电本身和控制方式,硬件和软件保证一个恰当的状态。电线接在用螺丝钉固定的端子排 上。 Fig. 8: max 50W with EAN823 and actuator for temperature range -25? ... +55?C 最大功率50W 温度范围-25? ... +55?C 主要工作电源AC115 / 230 VEBN861: 只用AC230 V Sub distribution board 最低分配 9.3 Connecting the cable shield 电缆保护管 将盒子电缆入口的罩子移开2厘 米。 打开电缆防护罩,折到后面 将电缆从入口插进去并用夹子固定 好; 确定护照向后折叠并用夹子连 着电线盒。 Fig. 10:Connecting the cable shield of EAN823; EBN853; EBN861 Screen connection at the actuator ist done accordingly. 图10;EAN823; EBN853; EBN861的电缆管防护罩 从而用线路连接 9.4 信号输入/输出实例 (常规的模拟/二元控制) 自动模式里切换的前提 (AUT): - 数字量输入信号D1, D2, 和 D3不能经过软件变动 (标准的默认出厂设置). - AUT模式用软件配置激活 (标准的默认出厂设置). 9.4.1 标准配线 (analogue setpoint) Fig. 11:接线端字的标准配线 9.4.2 控制器启动后 (二元控制没有模拟量) Contrac actuators feature smooth and continous operation even if the elctronic unit receives binary commands from a step controller. Use the configuration software for the appropriate settings. The electronic unit will then integrate the step commands and internally generate an analogue setpoint signal. 反相单元平滑特征,如果单元接到从步调控制器发来的二元命令,会连续平稳运行。使用软 件配置设置适当的参数。带电单元会使步调命令和模拟量信号成为一体。 步调发生器运行后可能配线 This operating mode requires the switch for the reference potential SYS to be set to这 个工作状态要求转换 设计 领导形象设计圆作业设计ao工艺污水处理厂设计附属工程施工组织设计清扫机器人结构设计 的电压SYS 回油到 9.5 有线制导 Pass and connect both the signal and the power cable separately within the plug housing in order to avoid electro magnetic interferences. A metal plate separates both cable areas from eachother. Connect the screen acc. to fig.13. 经过和连接两个信号和电源电缆个别的塞在盒子里面,避免与带磁性的电镀物品起冲突。一 个金属板隔离出电线范围,从各个筛子的连接处,看图 Fig. 13:Cable guidance within the plug 盒里有线制导 13.设置 Actuaror只需要基本的设置(适应运行的要求范围)为了运行或者细节配置。用就地控制面 板来完成这些设置。用适当的软件配置更详细的参数来改变或诊断功能。 13.1 设置就地控制面板 (LCP) 13.1.1 工作原理 1.写开关转换保护 (默认设置:关) 2.LED 定 调节器指示的100% 位置 , 保存位置, 或者挑剔不同的发光频率 3.按下启动按钮驱动器动作 4.按下重新启动按钮,处理器重新开始 5. LED显示有用的主要信号 6.RS 232 通过线路连到 PC 7.可能拨动开关连接参考电压,到系统或者电部分的保护接地(系统默认设置) 8.调整程序LED 定 0% 位置 保存位置 或者挑不同的动作频率 9..按下按钮同意并定义当前的位置为0%,同时按下按钮9+10完成调试 10.按下按钮同意并定意当前的位置为100%; 同时按下按钮9+10完成调试 图25: 就地控制面板 (LCP) 控制范围出厂时没有定 13.1.2 调试程序 - 松开LCP盖子上的螺丝 - 旋转盖子到旁边 13.1.3 初始位置 - 连接电源和控制 -写保护 开关设置为 “OFF”位置 -运行模式 “MAN” (没有数字量输入) - 没有过错 (如果出现一个错误, LED以 4 Hz交替闪亮) 13.1.4设置 13.1.4.1“设置”模式 - 设置电子部分 “设置”模式, 按推进按钮 同时大约. 5秒钟, 到 LEDs (2 + 8) 防水,同时大约4赫兹 ( 通过工厂测试之后“设置" 模式 是标准的 ) 13.1.4.2 首先定位置(0% or 100%) (更高精度的位置) - 移动到想要的位置按按钮 (3). - 接受 0%或100%的位置, 按压按钮(10) 或(9); 关联的 LED 闪光频率大约是. 2 Hz 工人正确的估价, 另一个继续大约.4Hz 13.1.4.3 第二次定位置 (0% or 100%) - 移动到第二个位置压另一个按钮 (3). - 认可位置, 压下按钮 (10) 或者 (9); LEDs (2)和 (8) 闪光大约. 2Hz 评价 LEC评价法下载LEC评价法下载评价量规免费下载学院评价表文档下载学院评价表文档下载 一般正确 13.1.4.4 保存设置 - 保存设置同时立刻压按钮 (10 + 9); LEDs (2 + 8)显示oN(没有闪光)在保存设置前大约5秒时 -如果挑选的范围太小,LEDs 将重新闪光 4Hz.重新调整一个宽范围程序(看详细标注说明) 13.1.4.5 设置后修正 - 如果通过修正认可第一次评估,首先按重新安排按钮(4)然后重新设置 - 如果修正做好了,保存了设置,完整的调节程序必须重新再弄议会 13.2调节器用程序配置 A conductive ground connection is established between the PC and the CONTRAC electronics with the RS 232 communication cable. If the PC is grounded, this may cause a ground loop in the installation. 上下文的灵感帮助信息在整个事件里很有用。操作基础和安装说明谈及手动联合,号码41/68—001。一个传导范围的连接PCH和CONTRAC带着RS232电缆信息。如果PC接地,能造成安装范围弯曲 13.3 LCP的功能和信号 功能 指示 调试 调试方式的改变: 余辉时间到,两个发光二极管同时闪烁频率大按下并保持驱动器按钮五秒钟 约4Hz 移动到末尾 操作的时候两个二极管发光二极管继续以用LCP上相关联的驱动器按钮 4Hz的频率闪烁 保留第一个末端位置 关联的发光二极管以 2Hz的频率闪烁, 按按钮 0%或100% 另一个继续闪烁 4Hz. 保留第二个末端位置 关联的发光二极管以 2Hz的频率闪烁, 按按钮 0% 或 100% 同时到第一个 保存设置 两个发光二极管暂时地,同时熄灭 同时按 0% 和 100% 按钮 操作 正常的操作: MAN / AUT 发光二极管熄灭 在 CSF上操作按钮 发光二极管熄灭 优先于控制系统 解列模式 在移动固件过程中解列电,相反或电机坏,用 两个二极管表示可用 ECOM 688软件程序 故障(两个二极管交替闪烁频率 4Hz) 重新指示故障 如果没有故障条件存在,两个灯都熄灭 (如果设备移动到它的操作范围之外, 驱动它 到优先级的后面 14.报警/故障 14.1 解说 14.1.1 报警 设备和电路部分暴露在风雨中的危险条件下 (或高温)当前不会损害设备, 电元单位, 易碰人. 设备功能仍然可以正常使用。应提前解救电元单位的纪录. ,用配置软件显示和解除警报. 14.1.2 故障 设备和电元单位暴露在风雨中的危急环境 (监视信号) 力量马上会损坏设备的时候, 电元单位, 处理或人. 设备跳闸设备功能不能长久使用. 出故障之前就解救电元单位的存储器. 用配置软件显示和解除警报.. 故障未处理前故障信息解除不了。 14.2 警报图解 跟踪设置 跟踪传达 维护 温度装置 上限 上限 润滑剂 / elastom. (高/低) 下限 下限 电机 / 传动装置 温度电元 (高/低) 检测 进行内容. ON ON behav. at crit. & & 临时. MAN AUT & actuator & 停止 安全 pos. 最后的 setpoint 装置用选定的模式 运行 报警信号 解除警报 (复位选项) 14.3 故障图解 硬件监测 监测回路布置 软件监测 转炉频率 -停止 传感器记忆错误位置 最后位置 - min. 速度 闪光错误 - 发故障命令 RAM 错误 看门狗活动 监测 发ON指令 & 发故障信号 故障信息经确认发 ON & 解除故障 (重启选择) 模拟量输出 1 ... 3.5 mA 低报“ 21.5 ... 25 mA 高报“ 15.发现并修理故障 这个部分主要讲述 怎样处理部件错误 . 涉及配置程序的在线帮助,把错误信息送给软件。 错误 可能的原因 处理方法 阀不能自动打开 设备或阀体故障 (e.g. 从阀上拆下设备 填塞料箱拉太紧) 如果设备工作正常,那么阀可能 有问 快递公司问题件快递公司问题件货款处理关于圆的周长面积重点题型关于解方程组的题及答案关于南海问题 ,另外 actuator 可能是故 障的原因 Actuator不起作用 电元失常 或指令错误 比较 actuator 和electronic unit的 lables 数据 电路设置不完美 用配置参数核对/修改设置 与 DCS通讯不畅 核对配线 电动头与装置通讯不畅 核对配线 电机/刹车不灵 检查电机与刹车的电阻线 ,检查 刹车保险 电路的数字量输入不连接 连接 Actuator 不能自动工作, 数字量输入1 (DI 1) 不能够连接 - 连接 DI 1 尽管配置程序选择“AUT- 检查数字量输入部分的软件设“ 置 发光二极管在试运和维修Actuator 动作范围超限 调整Actuator 的工作范围 时同时闪光 (看电元的说明书). 接近一个终点位置时故障 Actuator 工作在位置传感器的极- 用手移动任意一个 actuator 限范围 或者用 LCP 按钮来决定远处的 终端位置 (如果需要,从阀体上 拆掉). - 如果需要再接合阀体,移动 actuator后面 ,(如果可以这样做) - 使 actuator 适应新的工作范围 书中横卧着整个过去的灵魂——卡莱尔 人的影响短暂而微弱,书的影响则广泛而深远——普希金 人离开了书,如同离开空气一样不能生活——科洛廖夫 书不仅是生活,而且是现在、过去和未来文化生活的源泉 ——库法耶夫 书籍把我们引入最美好的社会,使我们认识各个时代的伟大智者———史美尔斯 书籍便是这种改造灵魂的工具。人类所需要的,是富有启发性的养料。而阅读,则正是这种养料———雨果
本文档为【ABB电动门说明书解读】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_314871
暂无简介~
格式:doc
大小:276KB
软件:Word
页数:28
分类:
上传时间:2018-03-09
浏览量:44