首页 京沪线上海局管段牵引供电开通方案

京沪线上海局管段牵引供电开通方案

举报
开通vip

京沪线上海局管段牵引供电开通方案 目目目目 录录录录 1、编制依据·························································································································································1 2、工程概况及施工区段············································································...

京沪线上海局管段牵引供电开通方案
目目目目 录录录录 1、编制依据·························································································································································1 2、工程概况及施工区段··························································································································1 3、送电开通范围·············································································································································2 4、送电开通时间·············································································································································3 5、送电开通步骤·············································································································································3 6、送电开通组织及人员配置··············································································································4 7、各岗位送电工作职责·······················································································································11 8、接触网送电开通安全技术措施·······························································································13 9、牵引变电所启动 方案 气瓶 现场处置方案 .pdf气瓶 现场处置方案 .doc见习基地管理方案.doc关于群访事件的化解方案建筑工地扬尘治理专项方案下载 ·······················································································································15 10、送电开通领导小组和各项目部指挥组工作地点及通话联系方式······15 11、京沪线上海局管段供电示意图····························································································16 12、接触网送电开通应急抢修预案····························································································16 13、电力调度指挥及配合····················································································································18 附件一:牵引变电所启动方案········································································································19 附件二:各项目部接触网抢修作业组需准备的抢修材料工机具表············30 附件三:主要人员岗位、任务表··································································································32 附件四:抢修维护小组配置··············································································································51 附件五:京沪线上海局管段供电示意图···············································································56 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 1 1111 编制依据编制依据编制依据编制依据 1.1 中铁电化局集团京沪工程指挥部,2OO6 年 4 月 16 日下发[关于编制 〈京沪线牵引供电工程开通方案〉的通知]; 1.2 铁道第四勘察 设计 领导形象设计圆作业设计ao工艺污水处理厂设计附属工程施工组织设计清扫机器人结构设计 院京沪铁路徐沪段电气化工程设计有关文件、施 工设计图纸及变更设计并结合现场实际施工情况。 1.3 京沪铁路电气化工程(上海局管段)施工总承包 合同 劳动合同范本免费下载装修合同范本免费下载租赁合同免费下载房屋买卖合同下载劳务合同范本下载 [京沪指(2005) 施合 01 号]及补充合同。 1.4 TB10208-98 铁路电力牵引供电施工规范。 1.5 TB10421-2004 铁路电力牵引供电工程施工质量验收 标准 excel标准偏差excel标准偏差函数exl标准差函数国标检验抽样标准表免费下载红头文件格式标准下载 。 1.6 TB10401.2-2003 铁路电力牵引供电施工技术安全规则。 1.7 Q/TDJ1002-1999 铁路电力牵引供电工程标准化开通程序。 2222 工程概况及施工区段工程概况及施工区段工程概况及施工区段工程概况及施工区段 京沪线上海局管段北起上海局与济南局接口符离集站北侧的分相下锚处 (津浦线 K725+722),南至京沪线终端上海站(沪宁线 K0-810),含林浦支线、 南京西支线,正线全长592.34 公里;包括 74 个车站,72 个区间,3个枢纽 场(南翔、南京东、蚌埠东),4 个机务段(上海机务段、南翔机务段、南京 东机务段、蚌埠东机务段),5个机务折返段(蚌埠客、南京北、南京西、常 州东、苏州西);新建牵引变电所15个(陵家桥、连城、蚌埠东、石门山、 三界、滁州、永宁、南京东、六摆渡、丹阳、新闸镇、石塘湾、苏州西、昆 山、南翔),分区亭 14个(符离集、任桥、曹老集、风阳、卞庄、沙河集、 东葛、下蜀、镇江南、吕城、戚墅堰、硕放、唯亭、安亭),分区所兼开闭所 2 个(上海、南京),开闭所 4个(蚌埠、林场、南京东、南翔)。 本段接触网为直供加回流供电方式,采用全补偿直链型简单悬挂。接触 网设计标准按 200Km/h 速度目标值设计,正线接触网电分相采用六跨式带中 性区的绝缘锚段关节结构,并设置自动过分相装置,站场电分相采用元件式 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 2 分相绝缘器。 上海局管内沿线属亚热带季风气候。气象条件为:最高气温 40℃,最低 气温南京长江大桥已北-25℃,大桥以南-15℃,平均温度大桥以北10℃,大 桥以南 15℃,处于中雷区范围。全年雨量 1149 毫米,降雨日数 132 天,占全 年总日数的 36%。 本段铁路经安徽、江苏、上海两省一市,城镇较多,大部分车站及区间 均可通公路或便道;属平原地貌,地势平坦,地质大多为土质,铁路为填方 地带。 该段工程由铁道第四勘测设计院设计,由中铁电气化局集团联合体工程 总承包,工程监理:铁四院工程监理咨询公司和乌鲁木齐铁路监理公司,以 南京长江大桥为界,大桥以北为乌鲁木齐铁路监理公司。 3333 送电开通范围送电开通范围送电开通范围送电开通范围 3.13.13.13.1 接触网开通范围:接触网开通范围:接触网开通范围:接触网开通范围:符离集(津浦线 K725+722)—上海站(沪宁线 K0-810),京沪线正线、车站到发线、编发线、安全线以及有正规列车运行的 联络线和有电力机车、电动车组走行和作业的线路等。含南京枢纽京沪线以 及林浦支线、南京至南京西支线,上海枢纽京沪线安亭至上海段(不含南翔 编组站的上行到达场、下行出发场和沪杭线以及相关联络线)以及黄渡至封 浜(不含)联络线等。 其中:上海枢纽京沪线黄渡至江桥区间分相~上海站(里程K17+063~ K000-810)、黄翔联络线、黄封联络线、南翔机务段、南翔编组站(Ⅰ场、Ⅳ 场)、上海机务段与沪杭线同步开通,在京沪线黄渡至江桥区间分相北京方向 侧做半永久性接地,京沪线开通前绝缘测试时拆除。本次开通范围为:符离 集(津浦线 K725+722)~京沪线黄渡至江桥区间分相(K17+063)。 电化二公司第一(蚌埠)项目部开通范围为:符离集(含)-林场(含),共计 32 站 32 区间,2个机务段,7个变电所,7个分区所,2 个开闭所。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 3 电化二公司第二(南京)项目部开通范围为:林场(不含)-镇江(含),共 计 9 站 8 区间,2 个机务段,2 个变电所,1个分区所,1 个开闭所,1个分区 所兼开闭所。 电化分公司第三(常州)项目部开通范围为:镇江(不含)-无锡(不含), 共计 14 站 14 区间,1 个机务折返段,3个变电所,3 个分区所。 电化分公司第二(苏州)项目部开通范围为:无锡(含)-安亭(不含),共 计 13站 13 区间,1个机务折返段,2个变电所,2个分区所。 电化分公司第一(江桥)项目部开通范围为:安亭(含)-黄渡(含),共计 2 站 1 区间,1个变电所(已带电),1 个分区所。 3.23.23.23.2 牵引变电所、亭:牵引变电所、亭:牵引变电所、亭:牵引变电所、亭:牵引变电所 15个、分区亭 14 个,分区所兼开闭 所 2 个,开闭所 4 个全部投入开通运行。 其中:南翔变电所、南翔开闭所、上海分区所兼开闭所,与沪杭线同时 投入运行;京沪线开通时,黄渡至江桥区间分相(K17+063)至安亭陆家浜区 间分相由南翔变电所送电。 4444 送电开通时间送电开通时间送电开通时间送电开通时间 全线变电所于 2006 年 6 月 20 日 10:00 时受电启动,6月 25 日全部完成, 并空载运行。6月 28 日 10:00 时向接触网送电。 5555送电开通步骤送电开通步骤送电开通步骤送电开通步骤 5.1 6 月 26 日 18:00 时后,京沪全线视为接触网带电,凡登高施工作 业,必须向电调中心请求停电作业命令,作业按停电作业办理。 5.2 6 月 27 日上午 10:00 时开始,蚌埠东牵引变电所向蚌埠东机务段 送电,以利电力机车进行整备。 5.3 6 月 28 日 10:00 时开始,按照电调命令,由上海向北京方向沿线 各牵引变电所依次给接触网送电,由接触网专业在分区所接触网未端验电, 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 4 待变电所全部给接触网送完电之后、且接触网、变电所专业验电结束、再按 上述顺序依次启动各开闭所、分区所。 6666 送电开通组织及人员配置送电开通组织及人员配置送电开通组织及人员配置送电开通组织及人员配置 6.16.16.16.1 组织机构图组织机构图组织机构图组织机构图 6.26.26.26.2 上海指挥部送电开通领导小组在局集团公司京沪线总指挥部送电开 通领导小组的领导下,负责所承建的京沪线接触网、变电工程的开通送电工 作。 6.2.16.2.16.2.16.2.1 上海指挥部送电开通领导小组(略)上海指挥部送电开通领导小组(略)上海指挥部送电开通领导小组(略)上海指挥部送电开通领导小组(略) 6.2.26.2.26.2.26.2.2 各项目部送电工作指挥组各项目部送电工作指挥组各项目部送电工作指挥组各项目部送电工作指挥组 上海指挥部依据施工管段,下设五个现场送电工作指挥组。 6.2.2.16.2.2.16.2.2.16.2.2.1 电化二公司第一电化二公司第一电化二公司第一电化二公司第一((((蚌埠蚌埠蚌埠蚌埠))))项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组 (略)(略)(略)(略) 电化二公司第一(蚌埠)项目部电调小组 电化二公司第一(蚌埠)项目部接触网第 1 送电指挥小组 项 目 部 送 电 工 作 指 挥 组 变电专业 指挥组 变电专业 故障处理组 接触网专业 指挥组 接触网专业 抢险维护组 变电所值班员 驻站联络员 区间联络员 电 力 调 度 组 上 海 指 挥 部 送 电 开 通 领 导 小 组 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 5 电化二公司第一(蚌埠)项目部接触网第 2 送电指挥小组 电化二公司第一(蚌埠)项目部接触网第 3 送电指挥小组 电化二公司第一(蚌埠)项目部接触网第 4 送电指挥小组 电化二公司第一(蚌埠)项目部接触网第 5 送电指挥小组 电化二公司第一(蚌埠)项目部接触网第 6 送电指挥小组 电化二公司第一(蚌埠)项目部变电第 1送电指挥小组 电化二公司第一(蚌埠)项目部变电第 2送电指挥小组 6.2.2.26.2.2.26.2.2.26.2.2.2 电化二公司第二电化二公司第二电化二公司第二电化二公司第二((((南京南京南京南京))))项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组 电化二公司第二(南京)项目部电调组 电化二公司第二(南京)项目部变电专业组 电化二公司第二(南京)项目部接触网专业组 6.2.2.36.2.2.36.2.2.36.2.2.3 电化分公司第三电化分公司第三电化分公司第三电化分公司第三((((常州常州常州常州))))项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组 电化分公司第三(常州)项目部电调组 电化分公司第三(常州)项目部变电专业组 电化分公司第三(常州)项目部接触网专业组 6.2.2.46.2.2.46.2.2.46.2.2.4 电化分公司第二电化分公司第二电化分公司第二电化分公司第二((((苏州苏州苏州苏州))))项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组 电化分公司第二(苏州)项目部电调组 电化分公司第二(苏州)项目部变电专业组 电化分公司第二(苏州)项目部接触网专业组 6.2.2.56.2.2.56.2.2.56.2.2.5 电化分公司第一电化分公司第一电化分公司第一电化分公司第一((((江桥江桥江桥江桥))))项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组项目部送电工作指挥组 电化分公司第一(江桥)项目部电调组 电化分公司第一(江桥)项目部变电专业组 电化分公司第一(江桥)项目部接触网专业组 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 6 6.2.36.2.36.2.36.2.3 各项目部设置牵引变电所亭值班、启动倒闸运行指挥小组,接触 网送电指挥小组,供电臂未端验电小组,隔离开关监视小组,驻站值班负责 人,区间巡视组,隧道、特大桥观察组,抢修及维护小组。小组人员岗位及 任务见附件三。 7777 各岗位送电工作职责各岗位送电工作职责各岗位送电工作职责各岗位送电工作职责 7.1 上海指挥部开通送电工作指挥组:在集团公司京沪开通领导小组的 领导下,全面负责京沪线上海局管段的开通送电工作,下达本区段的送电开 通命令及处理开通后至维管单位接收前的供电运行管理维护工作。 7.2 牵引变电所启动运行指挥小组:受电调指挥,负责本所的开关、断 路器的倒闸工作。在规定的时间内,在本变电所、开闭所、分区所值班,按 规定定期对变电所、开闭所、分区所设备进行巡视并将情况报告给电调,做 好值班记录。 7.3 各项目部接触网专业指挥小组:负责本专业开通前的各项准备工作, 执行开通送电指挥组下达的命令,负责指挥送电安全抢修工作,反馈开通准 备工作和送电情况。 7.4 驻站值班负责人:接受相关接触网指挥小组的指令,指挥本站和指 定的相邻区间各类作业人员的监护、巡视、开关倒闸、验电工作。收集、反 馈送电有关工作情况。 7.5 验电小组:按安排时间,携带验电工、器具、通信工具,进入供电 臂末端或规定位置,受相邻站负责人的指挥,接受其验电命令,严格按验电 操作规程验电,及时汇报验电情况。 7.6 区间巡视人员:接受相邻站负责人的指令,对管辖区间的接触网、 回流线、供电线、吸上线、避雷器等设备进行巡回监视,检查线路送电后有 无故障、异常响声和放电现象,发现问题及时报告。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 7 7.7 隔离开关小组:按安排时间进入开关附近,检查开关状态是否符合 送电方案规定的状态。依照本站或相邻站负责人的命令,进行开关倒闸作业, 并观察受电后的外观现象,随时汇报有关情况。 7.8 抢修维护小组:送电前按计划编制抢修预案,如承力索断线、腕臂 折断、电连接烧断、倒杆等异常情况的应急处理预案,准备好抢修零件、工 具,妥善放置在抢修作业车上,并把抢修作业车停放在指定的位置,在规定 的时间内,集中待命。在接到抢修命令后,严格按抢修操作规程,完成指定 的接触网或变电所的抢修任务。 7.9 隧道、特大桥、低净空桥观察组:根据送电安排,携带合适的通信 工具,提前进入所在地点,受相邻站负责人的指挥,观察隧道、特大桥、低 净空桥在送电后和上、下行第一趟电力机车运行时的状况,随时汇报有关情 况。 8888 接触网送电开通安全技术措施接触网送电开通安全技术措施接触网送电开通安全技术措施接触网送电开通安全技术措施 8.1 送电开通前应在行人、车辆、通过道口及站台上支柱以及有关作业 车辆上检查已按规定悬挂“高压危险”“禁止攀登”等警告提示牌。 8.2 在变电所受电后,即视为接触网带电,所有接触网上部作业,必须 依据调度命令规定的时间、地点执行,严禁违令操作;任何施工作业必须按 以下停电作业程序进行: 申办停电手续申办停电手续申办停电手续申办停电手续----→→→→设置停电标示设置停电标示设置停电标示设置停电标示----→→→→验电、接地验电、接地验电、接地验电、接地----→→→→作业作业作业作业----→→→→拆除接地拆除接地拆除接地拆除接地→→→→报报报报 告电调、恢复送电告电调、恢复送电告电调、恢复送电告电调、恢复送电----→→→→验电。验电。验电。验电。 具体操作细则: (1)、填写停电作业申请书; (2)、向电调申请停电命令; (3)、接受停电命令,设置停电范围的临时标示; 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 8 (4)、在命令的时间内和规定的范围内先验电,确认无电后,再用接地 线将接触网或设备接地; (5)、按规程完成施工作业,人员机械全部撤离; (6)、拆除保护接地; (7)、填写停电作业结束通知书,向电调报告处理情况,请示恢复送电; (8)、接受送电命令; (9)、验电、撤离现场。 8.3 送电开通期间,所有接触网上作业均应采取安全接地措施,其操作 程序为:确认接触网无电后,先将临时接地线一端接钢轨,再将另一端接接 触网,作业完毕,临时接地线拆除顺序:先拆接触网端,再拆钢轨端。 8.4 送电时,检查、巡视人员应避免近距离观察可能发生爆炸的避雷器、 放电间隙等电气设备。 8.5 任何验电操作必须遵守下述验电作业程序。即: 接受验电指挥命令接受验电指挥命令接受验电指挥命令接受验电指挥命令----→→→→作好验电准备作好验电准备作好验电准备作好验电准备----→→→→接受监护人指令接受监护人指令接受监护人指令接受监护人指令→→→→渐升验电器渐升验电器渐升验电器渐升验电器→→→→ 确认验电器的显示结果确认验电器的显示结果确认验电器的显示结果确认验电器的显示结果----→→→→报告验电情况。报告验电情况。报告验电情况。报告验电情况。 8.6 隔离开关倒闸作业程序 任何开关倒闸作业,都必须按照下列开关倒闸作业程序进行。即: 接受倒闸命令→按规程完成倒闸作业→向发令人报告倒闸完成。 8.7 接触网绝缘、导通试验程序 接触网绝缘、导通试验之前,首先必须发出“试验期间,接触网有电的 通知”,在此期间必须做到,任何人员不得上接触网作业; 8.8 接触网送电前的检查、准备工作 (1)对接触网进行一次全面检查确认:各种安全距离、绝缘距离和限界 应满足要求;电连接、吸上线、接地线等的安装数量齐全正确和牢固可靠; 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 9 各种绝缘材料完整无损;隔离开关接线正确、触头接触密贴;各种标志牌、 警告牌齐全且符合要求,限界门安装高度符合要求。 (2)影响送电开通的全部路内外交叉、平行线路和树木、建筑物、架空 电力、通信线路应在开通前处理完毕,静态检测和动态检测所发现的问题已 全部处理完毕。 (3)施工期间设置的临时接地线已全部拆除,绝缘材料的包扎物已拆除, 绝缘子已在送电前 7天清洗完毕。 (4)参加送电开通的人员经过开通纪律和抢修教育培训并考核合格,达 到上岗要求。 (5)向接触网送电开通前6 天,接触网应进行供电臂的导通试验及绝缘 电阻测量,然后按开通方案核对所有隔离开关处于规定状态(按供电示意图) 并锁定。 (6)符离集站外与济南局接口处分相绝缘检测前应与电化局济南指挥部 联系。由于沪杭线及上海枢纽已经带电,在京沪线黄渡站东头分相绝缘处设 置半永久接地,在开通前二天,由电调下令撤除地线,并进行该供电臂绝缘 测试。 (7)按开通方案要求位置停放好抢修车辆并做好人员、工具、仪器仪表 和材料准备。 8.9 开通送电组织工作要点 (1)依据电气化工程开通方案,接触网、变电各专业施工作业队应制定 具体的接触网、变电所开通安排;确定送电指挥机构,将相关送电工作职责 落实到人。 (2)接触网专业,必须按照接触网开通送电安排,作好充分的工具、机 具、器具、材料等准备,数量、性能和质量应满足送电工作要求;特别是区 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 10 间隔离开关和特大桥、低净空桥、隧道,必须配备可靠的通讯工具;接触网 专业,还必须加强对每个送电人员的送电工作职责的交底、培训和现场演练。 (3)接触网带接地刀闸隔离开关的正常状态设置要求:为避免送电后至 正式运用前这段时间内,电力机车进入无电区而烧坏接触网,所有接触网线 路上,带接地刀闸的隔离开关设置在闭合状态。 9999 牵引变电所启动方案见附件一牵引变电所启动方案见附件一牵引变电所启动方案见附件一牵引变电所启动方案见附件一 10101010 送电开通领导小组和各项目部指挥组工作地点及通话联络送电开通领导小组和各项目部指挥组工作地点及通话联络送电开通领导小组和各项目部指挥组工作地点及通话联络送电开通领导小组和各项目部指挥组工作地点及通话联络 方式方式方式方式 变电所启动当日,上海指挥部送电开通指挥组设在上海电调中心。项目 部送电开通指挥组均在所启动受电的变电所。由电调与地调联系,经地调同 意启动后,上海指挥部送电开通指挥组调度长下令,按已批准的启动程序, 由项目部送电开通指挥组在变电所就地直接指挥值班人员操作启动。 接触网送电当日,上海指挥部送电开通指挥组在上海电调中心直接指挥。 接触网送电完成后,设在指挥部上海驻地。联系电话:021-65928762。 各项目部送电开通指挥组在向接触网送电当日,在各自管内变电所,接 触网送电后返回各自项目部驻地值班,联系电话分别是各项目部的生产调度 电话。 局上海指挥部送电指挥、各项目部送电工作指挥组、变电所之间联络采 用电调电话、各站电话,并以手机为辅;各项目部指挥组与各巡视组等其他 送电人员可采用报话机或手机;区间送电人员可采用报话机或手机;所有通 话应严格按照简捷、准确地说出事项、地点、时间、原因、陈述人。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 11 送电通信联络程序图送电通信联络程序图送电通信联络程序图送电通信联络程序图 11111111 京沪线上海局管段供电示意图见附件五。京沪线上海局管段供电示意图见附件五。京沪线上海局管段供电示意图见附件五。京沪线上海局管段供电示意图见附件五。 12121212 接触网送电开通应急抢修预案接触网送电开通应急抢修预案接触网送电开通应急抢修预案接触网送电开通应急抢修预案 为防止送电开通期间因外部因素或外力导致接触网悬挂出现事故,特按 照京沪线运营特点制定相应的应急抢修预案。 12.1 成立送电开通抢修组 接触网专业的抢修组按照网工区的布局由各项目部组建,上海局管段设 置 13个抢修组。每个抢修组由组长、副组长和15名技术工人组成(不含司 助人员)。 12.2 抢修车辆编组 每个抢修小组准备架线作业车1辆、轨道车 1辆、立杆吊车一辆、平板 车 2 辆(含吊车平板)。 12.3 抢修车辆停放网工区专用线。 12.4 抢修材料工具配备。各项目部接触网抢修作业组需准备的抢修材料 工具表见附件二。 12.5 事故抢修原则及安全规定 开通指挥组 电力调度组 变电专业 指挥组 变电专业 故障处理组 接触网专业 指挥组 接触网专业 抢险组 变电所值班员 驻站联络员 区间联络员 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 12 12.5.1 接触网自第一次送电时间开始,无论是否有电,均应按有电办理 停电作业手续。 12.5.2 事故抢修时应遵循“先通车、后恢复”的原则,快速组织抢修, 尽量缩小事故范围,减少事故损失。 12.5.3 验电、接地必须严格执行一人监护、一人操作的原则。 12.5.4 验电:设好防护后,必须检查需进行作业的电气设备是否有电, 确认无电加挂临时接地线后,方可进行作业。使用验电器时,要注意验电器 的电压等级,同时应在确知有电的设备上试验验电器的灵敏可靠。验电时必 须带绝缘手套、穿绝缘靴。 12.5.5 接地:装设临时接地线的顺序为,先接接地端,再用绝缘杆将另 一端接在停电的设备或接触网上,此时人体不得接触接地线。撤除时与上述 顺序相反。 12.6 接触网断线抢修应急预案 12.6.1 抢修小组到达故障点后,听从负责人统一指挥,防护人员按规定 在故障点两侧实施防护。 12.6.2 负责人根据抢修原则,对故障抢修方案立即做出决策。向电调提 出申请停电,停电后在故障段两侧设置接地线。针对事故严重状况确定抢修 作业方案。 事故现场接触网破坏严重时,应采取如下方案:即迅速将承力索、接触 线分段断开,清除至限界外,首先恢复通车。 如线索只有一处断,损坏轻微,可采用接头线夹进行连接,恢复接触网 悬挂系统,尽快开通线路。 如果事故状态比较严重,应采取加辅助线把接触网连通,先导通供电系 统,通知行车及机务部门要求电力机车在故障段限速通过,先保证通车,然 后根据事故范围确定恢复方案后再申请要点作业。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 13 12.6.3 抢修作业完成后,施工负责人应进行全面检查确认。 12.6.4 撤除接地线,施工负责人向电力调度消令,申请恢复送电。 12.6.5 恢复送电后,抢修人员应认真观察,待两列车安全通过后,简要 向项目部汇报,抢修人员撤回驻地,再详细向项目部抢修领导小组报告。抢 修领导小组向指挥部抢修领导小组报告。 13131313 电力调度指挥及配合电力调度指挥及配合电力调度指挥及配合电力调度指挥及配合 13.1 变电所受电启动和向接触网送电以及越区供电试验,均由送电指挥 组统一指挥,电调发布命令和执行所内操作。110kv 外部电源向牵引变电所 供电事宜由上海铁路局相关部门负责与地方电力部门联系。 13.2 电调从第一个变电所准备受电开始,进入电调所开始值班,负责收 集各项准备工作情况,并向送电开通指挥组汇报。变电所受电由各项目部按 批准后的启动方案实施。向接触网送电和越区供电命令,由送电开通指挥组 发布,电力调度执行命令。 13.3 南翔变电所向安亭分区所方向接触网送电,由上海局沪杭电调与上 海局京沪电调联系办理书面签字手续后,远动操作执行。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 14 附件一:牵引变电所启动方案附件一:牵引变电所启动方案附件一:牵引变电所启动方案附件一:牵引变电所启动方案 一、开通方案:一、开通方案:一、开通方案:一、开通方案: 1、牵引变电所先行受电冲击,并空载24小时。 2、牵引变电所空载24小时后,按调度命令向接触网送电。 二、变电所受、送电开通运行安全要求:二、变电所受、送电开通运行安全要求:二、变电所受、送电开通运行安全要求:二、变电所受、送电开通运行安全要求: (一)、受电前的准备工作: 1、受电前应成立送电开通指挥组,负责受电前的安全检查及受电领导工 作,审查操作程序。 2、受电前应对所有设备进行一次全面检查,将所有设备瓷件进行一次清 扫、擦拭。室内外各种与受电无关的杂物应清除干净,有影响受电的障碍物 均应撤除或改迁。 3、受电前,应对变电所进行一次全面检查,检查内容如下: 1)、所有电气设备安装应正确、牢固,充油设备油位、油压应符合标准, 各种开关及闭锁装置动作应灵活可靠。 2)、设备引线、接线和接地线应符合标准,各种电气距离应满足规程要 求。 3)、灯光、音响信号应显示正确,直流电源应符合要求。二次回路熔断 器型号、规格应符合设计要求并可靠导通。备用流互的二次线圈应短接。 4)、变电所的进线和馈线方向应和接触网的供电线、馈电线方向相一致。 5)、各种设备的安装调试记录、试验报告应齐全并符合规范要求。 4、受电前应安排足够的值班人员、抢修人员和警卫人员,制定《值班员 守则》,同时应组织认真学习开通方案,熟悉本身职责和安全操作规程及操作 方法 快递客服问题件处理详细方法山木方法pdf计算方法pdf华与华方法下载八字理论方法下载 、事故处理方法,做到操作时安全、准确无误。 5、受电开通使用的仪表、仪器,防护用品,绝缘工具,备品备件应准备 齐全,列出清单,逐项检查落实并经检查试验合格后方可使用。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 15 6、开通前,应配备良好的消防和通讯器材,同时应配备一定的交通工具 和医务人员。 7、受电前应核对设备、开关、刀闸编号,“分”“合”位置应与模拟图及 控制盘上相对应的操作开关一致。 8、变电所受电前,主要设备应有明确的警告、编号标志,同时有关开关 应挂“禁止分闸”“禁止合闸”标志牌。 9、受电前凡经检查测试完毕的电气设备,不需再动的应立即加封,设备 网栅、高压室、电容器室等均应加锁,钥匙交专人保管。 10、受电前所有隔离开关、断路器均应处于分闸状态,真空断路器小车 至试验位。110KV 侧进线隔离开关接地刀闸处于合闸位置(110KV 进线不带电 的情况下),27.5KV 馈线穿墙套管外侧应挂临时接地线。 11、本次开通变电所启动和向接触网送电全部所内操作,远动监视。 12、变电所经检查符合受电要求后,应加强保卫工作,凡与受电无关人 员不得擅自进入受电区域。 (二)、受电运行倒闸作业及巡视注意事项: 1、变电所倒闸前应有倒闸系统图,配备操作命令簿、运行记录等。 2、倒闸作业时,必须按照电调发布的命令执行,受令后要复诵确认无误 后,方可进行操作,操作时必须二人进行,一人监护,一人操作。 3、挂临时接地线时,必须先将接地线与接地螺栓可靠连接,然后再挂操 作杆,撤除时必须先撤操作杆,后撤接地线。 4、操作隔离开关时,用力要均匀,准确迅速,一次到位,中途不得停留 和发生过大冲击。 5、操作带电设备和撤挂接地线时,必须穿绝缘鞋,戴安全帽和绝缘手套。 6、倒闸作业完成后,值班人员要立即向电调报告完成时间,并正确地记 录在操作命令簿上。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 16 7、变电所受电后,值班员应按时巡视。巡视的内容:充油设备的油位、 油压、油温是否正常,有无浸油现象,瓷件有无闪烁,带电设备是否运行正 常,有无异常。监视各种灯光、音响信号是否正常,各种仪表、继电器、直 流电源运行情况是否正常,并要做详细记录。 8、变电所受电后,即按正常运行对待,有作业和故障处理,必须有电调 命令,并按变电所停电作业有关规定办理。 9、受电前对主变、所用变分接开关必须确认已在标准档位置,受电后发 现电压过高或过低,必须请示电调停电后调整,调整后要进行测试后方可投 入。 10、受电期间,如遇有危及人身和设备安全的紧急情况,来不及报告电 调时,值班员可采取果断措施,断开有关开关,再报告电调,但合闸时必须 经电调批准后方可进行。 11、在向接触网送电时,先确认接触网无人作业后,撤除馈线穿墙套管 外侧接地线,测试馈线绝缘电阻,并向电调报告,再按电调命令操作送电。 12、第一次向接触网送电,应将馈线保护的自动重合闸装置退出运行, 待运行一段时间后根据电调命令投入。 (三)、设备抢修停电作业注意事项: 1、停电作业必须按下列各项依次完成后,方可在停电设备上工作: 断开电源断开电源断开电源断开电源 悬挂警告牌及设防护栏杆悬挂警告牌及设防护栏杆悬挂警告牌及设防护栏杆悬挂警告牌及设防护栏杆 验电验电验电验电 接地。接地。接地。接地。 1)、断开电源:将需停电作业设备完全与电源断开,二者之间至少应有 一个明显的断开点,并应有防止一次设备送电和二次设备反送电的措施。 2)、悬挂警告牌、设防护栏杆:因停电作业在应断开设备的控制开关把 手上、隔离开关操作机构手柄和防止带电应切断的二次控制开关上挂“有人 工作,禁止合闸”的警告牌,以防误操作。凡检修人员不能进入的高压带电 区域均应设防护栏,并悬挂“止步,高压危险”的警告牌,以防止工作人员 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 17 误入危险区域。防护栏应牢固,符合要求。防护栏和警告牌的设置与撤除由 作业负责人决定,其它人不得随意移动和撤除。 3)、验电:设好防护后,必须检验需进行作业的设备是否有电,确认无 电后方可工作。使用验电器验电时,要注意验电器的电压等级,是否试验合 格,同时应在确知有电的设备上试验验电器是否灵敏可靠。验电时应戴绝缘 手套,穿绝缘靴。 4)、接地:验明设备无电后,应将设备进行接地,如遇两相或三相的线 路应同时短接接地。接地线应用不小于 25平方毫米的多股软铜线,安装和撤 除接地线应按有关操作规程执行。 2、本要求中未尽事宜,应按铁道部、电力部有关规定或由送电开通领导 小组根据具体情况决定。 三、送电开通变电所应重点检查的项目:三、送电开通变电所应重点检查的项目:三、送电开通变电所应重点检查的项目:三、送电开通变电所应重点检查的项目: (一)、主变压器: 1、检查分接开关位置是否在额定电压档位,并测试直流电阻。 2、一、二次引线接线螺栓是否紧固。 3、瓦斯继、高压套管是否放气,高压电容套管接地是否牢靠。 4、油位、温度计是否指示正确。 (二)、室外开关: 1、各种隔离开关是否在分开位置。 2、各开关接线是否牢靠。 3、手动及电动隔离开关分合动作是否正常。 4、各开关分合角度是否符合要求。 5、六氟化硫断路器气体及机构是否正常。 6、电动负荷开关电动分合是否可靠,接触是否符合要求。 (三)、电流、电压互感器、避雷器: 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 18 1、电流、电压互感器一次接线是否符合设计要求。 2、油位指示是否正常。 3、二次接线盒接线、接地是否牢靠。 4、引线连接螺栓连接是否牢靠。 5、室外端子箱接线、接地是否牢靠。 6、避雷器放电计数器指示是否在零位。 (四)、高压室: 1、所有硬母线连接是否牢靠。 2、馈出线相序是否正确,方向是否和接触网供电线方向一致。 3、所有开关是否在分闸位置。 4、所有连接部位是否紧固牢靠。 5、所有小车开关推合、闭锁是否灵活、可靠,是否在试验位置。 6、端子箱所有元件是否齐全,接地是否牢靠,接线是否正确。 7、所有网栅门锁是否已经配齐。 (五)、电容器室: 1、各种联线连接是否正确、牢靠。 2、各电容器的熔断器是否完好。 3、电抗器、电压互感器的联线是否在设计要求位置。 4、电抗器、电压互感器、避雷器、电容器的工作及保护接地是否正确、 牢靠。 5、所有网栅门锁是否已经配齐,距离电抗器的距离是否符合设计要求。 (六)、控制室: 1、所有仪表、继电器、开关、按钮是否完好齐全。 2、所有装置试验是否正常,灯光、音响装置是否完好。 3、所有控制方式开关是否在指定位置。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 19 4、所有开关位置是否与一次系统相一致。 5、所有继电器保护整定值是否按设计提供的定值进行整定。 6、所有二次继电保护动作是否正常。 7、交、直流盘电源是否正常可靠。 (七)、其它: 1、所有值班、抢修人员是否已配备到位。 2、所有备品、备件、工机具、材料是否已备齐。 3、开通用的仪表、仪器、防护用品、绝缘工具是否配备。 4、各所通讯设施是否完好,消防器材是否配备。 5、核对设备编号,开关、刀闸及位置是否与保护盘相对应的操作开关一 致。 6、受电前,有关设备应有明确的警告标志,同时有关开关和刀闸应挂“禁 止分闸”或“禁止合闸”的警告牌。 四、变电所开通运行值班制度:四、变电所开通运行值班制度:四、变电所开通运行值班制度:四、变电所开通运行值班制度: 1、值班员应树立高度的负责精神,严守工作岗位。 2、值班员应按电调命令内容操作,不准擅自操作属电调调度的开关。 3、操作时二人进行,一人监护,一人操作。操作时先在模拟盘按照命令 进行模拟操作,确认无误。执行操作命令时由监护人朗读操作命令,确认设 备状态,再由操作人操作。 4、上、下班应进行交接班,双方共同对所有设备进行一次巡视,确认设 备运行情况及值班应注意的地方,并共同签认,作好记录。 5、保持室内清洁卫生,每班上下班前应将室内卫生打扫干净。 五、各所亭开通启动前的工具准备五、各所亭开通启动前的工具准备五、各所亭开通启动前的工具准备五、各所亭开通启动前的工具准备 1、隔离开关操作棒1 根。 2、500V、2500V 兆欧表各 1 块。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 20 3、万用表 1块。 4、绝缘靴、手套两付,安全帽两顶。 5、三相临时接地线两套,单相临时接地线每条供电臂1 根。 6、各所亭应配备一定数量的“禁止分闸”、“禁止合闸”警告牌。 7、高压验电棒 10KV 1 支、35KV 1 支、110KV 1 支,零克棒 1 支。 六、牵引变电所受电冲击程序:六、牵引变电所受电冲击程序:六、牵引变电所受电冲击程序:六、牵引变电所受电冲击程序: 各变电所主变受电各变电所主变受电各变电所主变受电各变电所主变受电、、、、冲击冲击冲击冲击、、、、空载时倒闸操作程序空载时倒闸操作程序空载时倒闸操作程序空载时倒闸操作程序((((第第第第 1111号命令号命令号命令号命令----第第第第7777号命号命号命号命 令令令令))))完全相同完全相同完全相同完全相同,,,,向接触网上供电时各所开关操作步骤不同向接触网上供电时各所开关操作步骤不同向接触网上供电时各所开关操作步骤不同向接触网上供电时各所开关操作步骤不同,,,,详见第详见第详见第详见第 8888号命令号命令号命令号命令。。。。 1111号命令号命令号命令号命令((((110K110K110K110KVVVV线路带电前线路带电前线路带电前线路带电前)))):撤除110KV进线外侧临时接地线,分1013D、 1023D 接地刀闸。 2222号命令号命令号命令号命令 110KV110KV110KV110KV抽压装置受电抽压装置受电抽压装置受电抽压装置受电(按两路 110KV 线路带电考虑) 1)、合 1013 刀闸,观察 1#110KV 线路中相母线电压,做好记录,将结果 报告电调。 2)、合 1023 刀闸,观察 2#110KV 线路中相母线电压,做好记录,将结果 报告电调。 3333号命令号命令号命令号命令 1#1#1#1#、、、、2#2#2#2#主变受电冲击主变受电冲击主变受电冲击主变受电冲击(以一号进线为主供电源,一号主变 按直列,二号主变按交叉运行考虑)。 1)、合 1012、1022、1002 手动刀闸。 2)、合 1011 刀闸,观察 1#110KV 线路母线电压、核相、做好记录,将结 果报告电调。依次合 1003 刀闸、101 开关,1#主变第一次受电冲击,观察 10 分钟,手动分闸。 3)、合 101 开关,1#主变第二次受电冲击,观察5分钟,模拟差动保护 分闸。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 21 4)、合 101 开关,1#主变第三次受电冲击,观察5分钟,模拟重瓦斯保 护分闸。 5)、依次合 2511、2512、2521、2522、2001、2002 刀闸,将 201A、201B 开关推至工作位,合 101 开关,1#主变第四次受电冲击,合 201A、201B 开关, 观察 27.5KV 母线电压,观察 5 分钟,模拟 110KV 电源失压保护分闸;分 201A、 201B 开关。 6)、合 1001 刀闸,观察 2#110KV 线路母线电压、核相、做好记录,将结 果报告电调。依次合 1004 刀闸、102 开关,2#主变第一次受电冲击,观察 10 分钟,手动分闸。 7)、合 102 开关,2#主变第二次受电冲击,观察5分钟,模拟差动保护 分闸。 8)、合 102 开关,2#主变第三次受电冲击,观察5分钟,模拟重瓦斯保 护分闸。 9)、将 202A、202B 开关推至工作位,合 102 开关,2#主变第四次受电冲 击,合 202A、202B 开关,观察 27.5KV 母线电压,观察5 分钟,模拟 110KV 电源失压保护分闸。 10)、合 102 开关,2#主变第五次受电冲击,观察 5分钟,分 202A、202B 开关,投入 2#主变互投装置,模拟 2#主变重瓦斯保护分闸,1#主变投入,1# 主变第五次受电冲击。 11)、1#主变互投成功,观察5 分钟,投入 1#主变互投装置,模拟1#过 热保护分闸,2#主变投入,2#主变第六次受电冲击; 4444号命令号命令号命令号命令 电容补偿装置受电冲击电容补偿装置受电冲击电容补偿装置受电冲击电容补偿装置受电冲击 1)、合 2311、2321 刀闸,并将 231、232 开关推至工作位。 2)、合 231 开关、1#电容器第一次受电冲击,观察5 分钟,分231开关。 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 22 3)、合 232 开关,2#电容器第一次受电冲击,观察5 分钟,分232开关。 4)、231 开关分闸 15 分钟后,合 231 开关,1#电容器第二次受电冲击, 观察 5分钟,分 231 开关。 5)、232 开关分闸 15 分钟后,合 232 开关,2#电容器第二次受电冲击, 观察 5分钟,分 232 开关。 6)、231 开关分闸 15 分钟后,合 231 开关,1#电容器第三次受电冲击, 观察 5分钟,分 231 开关。 7)、232 开关分闸 15 分钟后,合 232 开关,2#电容器第三次受电冲击, 观察 5分钟,分 232 开关。 8)、拉出 231、232 开关,分 2311、2321 刀闸。 5555号命令号命令号命令号命令 所用变受电所用变受电所用变受电所用变受电 合 2601 刀闸,1#所用变受电;观察 1#所用变电压,核对相序;进行 1#、 2#所用变低压交流电源互投。 6666号命令号命令号命令号命令 主变空载运行主变空载运行主变空载运行主变空载运行 1)、2#主变空载运行(24小时)。 2)、分 202A、202B 开关,并将开关拉至试验位置,依次合1003 刀闸、 101、201A、201B 开关,1#主变进行空载试运行(24小时)。 7777号命令号命令号命令号命令 准备向接触网送电准备向接触网送电准备向接触网送电准备向接触网送电 1)、撤除各所亭馈线侧室外穿墙套管外侧临时接地线。 2)、分别测试各所亭馈线上、下行接触网绝缘电阻,并报告电调。 3)、变电所及分区所处接触网分相电动隔离开关均处于分闸状态。 4)、根据电调命令,进行分区所室内外隔离开关及断路器倒闸作业,本 京沪线上海局管段电气化工程送电开通方案 中铁电气化局集团京沪线电气化工程上海指挥部 23 方案按分区所断路器合闸以实现供电臂末端并联的方式编制。 8888号命令号命令号命令号命令 向接触网送电向接触网送电向接触网送电向接触网送电 送电时,拆除馈线挂设的接地线,由电力调度所采用远方遥控操作向各 供电臂送电。 七、开闭所受电程序七、开闭所受电程序七、开闭所受电程序七、开闭所受电程序 在室外隔离开关外侧确认接触网上下行正线供电臂已带电,上、下行处于 不带电状态。 合 2511、2911 刀闸,下行正线供电臂电源进所,观察2911 供电臂末端 电压、做好记录,将结果报告电调。 合 2521、2921 刀闸,上行正线供电臂电源进所,观察2921 供电臂末端 电压、做好记录,将结果报告电调。 依次合 2001、2002、2601 刀闸,推合 291、292 开关,室内 27.5KV 母线 带电, 1#B 带电,观察室内母线电压、做好记录,将结果报告电调。 合 2931 刀闸、293 开关,向下行送电,在室外穿墙套管外侧验电,将验 电结果向电调汇报。 合 2941 刀闸、294 开关,向上行送电,在室外穿墙套管外侧验电,将验 电结果向电调汇
本文档为【京沪线上海局管段牵引供电开通方案】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_529331
暂无简介~
格式:pdf
大小:2MB
软件:PDF阅读器
页数:49
分类:交通与物流
上传时间:2011-07-24
浏览量:27