首页 ABB变频器-ACS800-操作面板介绍教程解析

ABB变频器-ACS800-操作面板介绍教程解析

举报
开通vip

ABB变频器-ACS800-操作面板介绍教程解析©Copyright2007ABB.Allrightsreserved.-*-*操作面板©Copyright2007ABB-*-控制变频器 控制盘控制和编程 可以安装在变频器上也可以安装在柜门上 键盘是扁平,带标签的按钮 LCD显示:4X20个字符*ControllingtheDrive:TheControlPanelisthedeviceusedforcontrollingandprogrammingtheACS800.Thepanelcanbeattacheddirectlytothemod...

ABB变频器-ACS800-操作面板介绍教程解析
©Copyright2007ABB.Allrightsreserved.-*-*操作面板©Copyright2007ABB-*-控制变频器 控制盘控制和编程 可以安装在变频器上也可以安装在柜门上 键盘是扁平,带标签的按钮 LCD显示:4X20个字符*ControllingtheDrive:TheControlPanelisthedeviceusedforcontrollingandprogrammingtheACS800.Thepanelcanbeattacheddirectlytothemoduleordoorofthecabinet.ThekeysontheControlPanelareflat,labeledpush-buttons.Thedisplayandfunctionkeysaredescribedinthefollowingslides.©Copyright2007ABB-*-显示 1:变频器状态 所选择变频器的ID号 控制盘状态: L=Local本地 R=Remote远程 旋转方向: =Forward(正转) =Reverse(反转) Valueofthereference给定值 Runstatus:运行状态 I=Run(运行) 0=Stop(停止) ‘’=Nostartpermission(无使能信号) 2-4:实际信号名称和值1234*Thefirstrowofthedisplayshowsthedrivestatus,andtheotherrowstheactualsignals.Thedisplaychangesaccordingtowhatmodeiscurrentlyactive.E.g.pressingACTchangesthemodetotheActualvaluedisplay©Copyright2007ABB-*-操作模式键 操作模式键 Actual(显示操作数据或实际信号) Parameter(显示和编辑参数名称和参数值) Function(进入助手向导和上载/下载参数) Drive(在网络中分配传动的ID号)*OperationModeKeys:TheActualkeyisusedtodisplayoperationaldataandtheactualsignals,parametertodisplayandeditparameters,functiontolaunchassistantsanduploadordownloadparameters,anddrivetoassignDriveIDnumbersonanetwork.©Copyright2007ABB-*-变频器控制键 变频器控制键 Start–启动变频器 Stop–停止变频器 REF-通过控制盘设置给定值 ForwardandReversekeys-改变电机旋转方向 LOC/REM-在本地和远程切换控制模式 RESET-故障复位*TheControlPanelhaskeysto:Startandstopthedrive,setthereferencevalue,changethedirectionofthemotor,changebetweenlocalandremotecontrolmodes,andresetthedriveifafaultoccurs,©Copyright2007ABB-*-读取实际值 这个模式包括两个显示:实际值信号显示和故障记录显示 实际值信号显示是显示所选择的信号的实时值 实际值信号显示下面的信息: 状态栏 三个可选择的实际信号 参数值可以通过箭头键和ENTER键来更改状态栏实际信号*ReadingActualValues. ThepanelwillautomaticallyreturntotheActualSignalDisplayMode(fromtheothermodes)ifnokeysarepressedwithinoneminute(exception:FaultDisplayMode). IntheActualSignalDisplayMode,threeActualSignalscanbemonitoredatonetime. FaultHistoryDisplaywillbediscussedlateron.©Copyright2007ABB-*-设置参数 参数模式是用来改变ACS800参数 控制盘显示下面的信息: 状态栏 参数组和名称 参数号和名称 参数值 改变参数 参数组通过双前头键来更改 参数号通过单箭头键来更改 参数值可以通过箭头键和ENTER键来更改*SettingUpParameters:WhentheParametermodeisenteredforthefirsttimeafterPowerUp,thedisplaywillshowthefirstparameterofthefirstgroup.ThenexttimetheParameterModeisentered,thepreviouslyselectedparameterisshown.WhenpressingtheENTERkeyforthefirsttime,bracketswillappeararoundthevalueandwhenacceptingthevaluewiththeENTERkeythebracketswilldisappear.©Copyright2007ABB-*-读取警告和故障信息 当故障和警告发生时,出现故障显示 控制盘显示下面信息: 状态栏 传动型号 故障或警告信息 警告或故障名称. 故障能通过RESET键或PC工具复位*ReadingAlarm&FaultMessages:WhenafaultorwarningoccursintheDrive,amessagewillbedisplayed,exceptintheDriveSelectionMode.Thefaultorwarningtextremainsdisplayedaslongasthefaultexistsandnokeysarepressed.FromtheFaultDisplay,itispossibletochangetootherdisplayswithoutresettingthefault.©Copyright2007ABB-*-故障历史记录 通过ACT键和双箭头按钮选择故障记录 控制盘显示下面信: 事件的序号,从最近一个事件 警告或故障的名称 事件符号+事件激活-事件复位 累计上电时间 通过单箭头键可以查看变频器的故障记录*SelectFaultHistoryDisplaybypressingtheACTbuttonandthenthedoublearrowbutton.Thedisplaypanelwillshowthefollowinginformation:Thesequentialnumberoftheevent,1beingthemostrecentevent.Thenameofthewarningorfault.Theeventstatuswhere:APlus(+)indicatesthattheeventisactive,andaMinus(-)indicatesthattheeventisdeactivated,andthetotalpower-ontime.BypressingthearrowkeysyoucanscrollthroughtheFaultHistory.©Copyright2007ABB-*-功能模式 功能模式是用来选择特殊功能的 变频器助手向导(仅用于单传动),用助手向导能启动向导程序来设置变频器 参数上传和下载 设置控制盘对比度 选择功能 通过双前头键来翻页 通过单箭头键来选择功能 光标所在行时按ENTER键确认所选择的功能*TheFunctionModeisusedtoselectspecialfunctions,suchas:Driveassistants(onlyinsingledrives),parameteruploadordownload,andsettingthecontrastoftheControlPaneldisplay.©Copyright2007ABB-*- 传动模式显示变频器的基本信息: 变频器型号 变频器软件版本和测试日期 变频器ID号 符号状态 变频器停止,方向为正 变频器运行,方向为负 变频器故障触发 正常情况下传动选择模式功能是不需要的(PanelLink网络)传动模式*TheDrivemodedisplaycontainsbasicinformationofthedrive,suchastheDrivetype,thesoftwareversionandtestdate,thedriveIDnumber,anddrivestatussymbols.ThefunctionsavailableintheDriveSelectionModearenotneededduringnormalusage.ThesefunctionsarereservedforapplicationswhereseveraldrivesareconnectedtoaPanelLink.APanelLinkisacommunicationlinkconnectingtheControlPanelwiththeACS800.WhenaPanelLinkisused,eachon-linestationmusthaveanindividualidentificationnumber(ID).Bydefault,theIDnumberoftheACS800is1.ThedefaultIDnumbersettingoftheACS800shouldnotbechanged,unlessitwillbeconnectedtothePanelLinkwithotherdriveson-line.ThepoweroftheACS800mustbeswitchedofftovalidateitsnewIDnumbersetting(thenewvalueisnotdisplayeduntilthepowerisswitchedoffandonagain).TheControlPanelwilldisplaythestatusofalldevicesconnectedtothePanelLinkwhenanarrowkeyispressedandastationchangetothearrowdirectioninthePanelLinkisnotpossible.©Copyright2007ABB-*-*ControllingtheDrive:TheControlPanelisthedeviceusedforcontrollingandprogrammingtheACS800.Thepanelcanbeattacheddirectlytothemoduleordoorofthecabinet.ThekeysontheControlPanelareflat,labeledpush-buttons.Thedisplayandfunctionkeysaredescribedinthefollowingslides.*Thefirstrowofthedisplayshowsthedrivestatus,andtheotherrowstheactualsignals.Thedisplaychangesaccordingtowhatmodeiscurrentlyactive.E.g.pressingACTchangesthemodetotheActualvaluedisplay*OperationModeKeys:TheActualkeyisusedtodisplayoperationaldataandtheactualsignals,parametertodisplayandeditparameters,functiontolaunchassistantsanduploadordownloadparameters,anddrivetoassignDriveIDnumbersonanetwork.*TheControlPanelhaskeysto:Startandstopthedrive,setthereferencevalue,changethedirectionofthemotor,changebetweenlocalandremotecontrolmodes,andresetthedriveifafaultoccurs,*ReadingActualValues. ThepanelwillautomaticallyreturntotheActualSignalDisplayMode(fromtheothermodes)ifnokeysarepressedwithinoneminute(exception:FaultDisplayMode). IntheActualSignalDisplayMode,threeActualSignalscanbemonitoredatonetime. FaultHistoryDisplaywillbediscussedlateron.*SettingUpParameters:WhentheParametermodeisenteredforthefirsttimeafterPowerUp,thedisplaywillshowthefirstparameterofthefirstgroup.ThenexttimetheParameterModeisentered,thepreviouslyselectedparameterisshown.WhenpressingtheENTERkeyforthefirsttime,bracketswillappeararoundthevalueandwhenacceptingthevaluewiththeENTERkeythebracketswilldisappear.*ReadingAlarm&FaultMessages:WhenafaultorwarningoccursintheDrive,amessagewillbedisplayed,exceptintheDriveSelectionMode.Thefaultorwarningtextremainsdisplayedaslongasthefaultexistsandnokeysarepressed.FromtheFaultDisplay,itispossibletochangetootherdisplayswithoutresettingthefault.*SelectFaultHistoryDisplaybypressingtheACTbuttonandthenthedoublearrowbutton.Thedisplaypanelwillshowthefollowinginformation:Thesequentialnumberoftheevent,1beingthemostrecentevent.Thenameofthewarningorfault.Theeventstatuswhere:APlus(+)indicatesthattheeventisactive,andaMinus(-)indicatesthattheeventisdeactivated,andthetotalpower-ontime.BypressingthearrowkeysyoucanscrollthroughtheFaultHistory.*TheFunctionModeisusedtoselectspecialfunctions,suchas:Driveassistants(onlyinsingledrives),parameteruploadordownload,andsettingthecontrastoftheControlPaneldisplay.*TheDrivemodedisplaycontainsbasicinformationofthedrive,suchastheDrivetype,thesoftwareversionandtestdate,thedriveIDnumber,anddrivestatussymbols.ThefunctionsavailableintheDriveSelectionModearenotneededduringnormalusage.ThesefunctionsarereservedforapplicationswhereseveraldrivesareconnectedtoaPanelLink.APanelLinkisacommunicationlinkconnectingtheControlPanelwiththeACS800.WhenaPanelLinkisused,eachon-linestationmusthaveanindividualidentificationnumber(ID).Bydefault,theIDnumberoftheACS800is1.ThedefaultIDnumbersettingoftheACS800shouldnotbechanged,unlessitwillbeconnectedtothePanelLinkwithotherdriveson-line.ThepoweroftheACS800mustbeswitchedofftovalidateitsnewIDnumbersetting(thenewvalueisnotdisplayeduntilthepowerisswitchedoffandonagain).TheControlPanelwilldisplaythestatusofalldevicesconnectedtothePanelLinkwhenanarrowkeyispressedandastationchangetothearrowdirectioninthePanelLinkisnotpossible.
本文档为【ABB变频器-ACS800-操作面板介绍教程解析】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: ¥11.9 已有0 人下载
最新资料
资料动态
专题动态
个人认证用户
真诚文档交流
本人从事临床麻醉五年有余,工作兢兢业业,拥有丰富的临床麻醉经验及临床医学资料,并取得了助理医师资格。
格式:ppt
大小:836KB
软件:PowerPoint
页数:0
分类:高中其他
上传时间:2020-02-18
浏览量:54