首页 Kistler测力仪软件DynoWare使用说明书

Kistler测力仪软件DynoWare使用说明书

举报
开通vip

Kistler测力仪软件DynoWare使用说明书InstructionManualDynoWareType2825A…2825A_002-195e-02.11Page1InstructionManualDynoWareType2825A…2825A_002-195e-02.11Foreword2825A_002-195e-02.11Page2ForewordThismanualiswrittenforDynoWare,ageneral-purposedataacquisitionandanalysissoftware.Informat...

Kistler测力仪软件DynoWare使用说明书
InstructionManualDynoWareType2825A…2825A_002-195e-02.11Page1InstructionManualDynoWareType2825A…2825A_002-195e-02.11Foreword2825A_002-195e-02.11Page2ForewordThismanualiswrittenforDynoWare,ageneral-purposedataacquisitionandanalysissoftware.Informationinthisdocumentissubjecttochangewithoutnotice.Kistlerreservestherighttochangeorimproveitsproductsandmakechangesinthecontentwithoutobligationtonotifyanypersonororganizationofsuchchangesorimprovements.©2002…2011KistlerGroup.Allrightsreserved.Exceptasexpresslyprovidedherein,nopartofthismanualmaybereproducedforanypurposewithouttheexpresspriorwrittenconsentofKistlerGroup.KistlerGroupEulachstrasse228408WinterthurSwitzerlandTel.+41522241111Fax+41522241414info@kistler.comwww.kistler.comDynoWare,Type2825A…Page32825A_002-195e-02.11Content1.Introduction....................................................................................................................................71.1GettingSoftwareHelp.............................................................................................................81.2CustomerSupport...................................................................................................................81.3ServiceandAssistance.............................................................................................................91.4LicenseAgreement..................................................................................................................91.5Warranty.................................................................................................................................91.6Claims...................................................................................................................................102.ImportantInformation..................................................................................................................112.1ForyourSafety......................................................................................................................112.2Warning................................................................................................................................112.3HowToUseThisManual......................................................................................................113.DescriptionofDynoWare.............................................................................................................123.1General..................................................................................................................................123.2SystemRequirements............................................................................................................134.Installation....................................................................................................................................144.1DynoWareSoftwareInstallation............................................................................................144.2HASPKeyInstallation............................................................................................................164.3InstallingDataAcquisitionCard.............................................................................................174.3.1PCIM-DAS1602/16...............................................................................................................174.3.2PC-CARD-DAS16/16............................................................................................................184.3.3Type5697ADAQ-SystemforDynoWare(USB2533)............................................................194.4A/DCardConfiguration........................................................................................................204.4.1PCIM-DAS1602/16...............................................................................................................214.4.2PC-CARD-DAS16/16............................................................................................................214.4.3Type5697ADAQ-SystemforDynoWare(USB2533)............................................................224.5SetCardNumbertoZero......................................................................................................224.6RunningDynoWare...............................................................................................................234.7ConnectingtheMeasurementSignalCable("AnalogInput")...............................................234.7.1PCIM-DAS1602/16andPC-Card-DAS16/16........................................................................234.7.2Type5697ADAQ-SystemforDynoWare..............................................................................244.8ConnectingRS-232CInterfaceCable....................................................................................254.8.1ConnectingtoPC/Notebook...............................................................................................254.8.2ConnectingtoConnectingBoxType5697A..........................................................................254.9UsingRemoteControlInterfaceonDAQ-SystemType5697A..............................................274.10ImportantIssuesRegardingPiezoelectricDynamometers......................................................274.11ChargeAmplifiers..................................................................................................................275.QuickStart....................................................................................................................................286.Reference......................................................................................................................................316.1File........................................................................................................................................316.1.1Open….................................................................................................................................316.1.2Savemodifiedfile..................................................................................................................316.1.3Configuration........................................................................................................................326.1.3.1Load….................................................................................................................................32Content2825A_002-195e-02.11Page46.1.3.2Save…..................................................................................................................................326.1.4Export…...............................................................................................................................336.1.5Print......................................................................................................................................356.1.6PrintPreview….....................................................................................................................366.1.7PrintSetup…........................................................................................................................386.1.8CopytoClipboard................................................................................................................386.1.9Exit.......................................................................................................................................386.2Acquisition............................................................................................................................386.2.1Hardware…..........................................................................................................................386.2.1.1A/DCard..............................................................................................................................396.2.1.2ShowHardwareDialogbetweenAcquisitionCycles.............................................................406.2.1.3AmplifierSelection................................................................................................................406.2.1.4ConfigurationsusingAmplifierType5017/5019..................................................................416.2.1.4.1MultichannelAmplifierType5017/5019..............................................................................416.2.1.4.2RS-232CSetup.....................................................................................................................416.2.1.4.3Force&TorqueCalculation...................................................................................................426.2.1.5ConfigurationsusingType5011/5015amplifiers.................................................................456.2.1.5.1ChargeAmplifierType5011/5015.......................................................................................456.2.1.5.2RS-232CSetup.....................................................................................................................466.2.1.6SetupforChargeAmplifierType5018..................................................................................466.2.1.6.1ChargeAmplifierType5018.................................................................................................466.2.1.6.2RS-232CSetup.....................................................................................................................476.2.1.6.3USBSetup.............................................................................................................................476.2.1.7ConfigurationsusingOtherAmplifiers..................................................................................476.2.1.7.1Others..................................................................................................................................486.2.1.8ConfigurationsUsingRotatingCuttingDynamometerType9123/9124withSignalConditionerType5223.........................................................................................................486.2.1.8.1RCD5223.............................................................................................................................486.2.1.8.2RS-232CSetup.....................................................................................................................496.2.1.8.3RCDCalculations..................................................................................................................496.2.1.9ConfigurationsUsingRotatingCuttingDynamometerType9125withSignalConditionerType5237............................................................................................................................516.2.1.9.1RCDType5237....................................................................................................................516.2.1.9.2RS-232CSetup.....................................................................................................................516.2.1.10ConfigurationsusingMultichannelAmplifierType5070.......................................................526.2.1.10.1MultichannelAmplifierType5070........................................................................................526.2.1.10.2RS-232CSetup.....................................................................................................................536.2.1.10.3Force&MomentCalculation................................................................................................536.2.1.11SetupforMultichannelChargeAmplifierType5080............................................................566.2.1.11.1MultichannelAmplifierType5080........................................................................................566.2.1.11.2RS-232CSetup.....................................................................................................................576.2.1.11.3USBSetup.............................................................................................................................576.2.1.11.4Force&TorqueCalculation...................................................................................................586.2.2Edit…....................................................................................................................................606.2.2.1Parameter.............................................................................................................................616.2.2.2Channels...............................................................................................................................626.2.2.3DataManipulation................................................................................................................636.2.3art.........................................................................................................................................646.3View.....................................................................................................................................666.3.1New…..................................................................................................................................666.3.2Edit…....................................................................................................................................666.3.2.1Superimpositionofviews......................................................................................................676.3.3Setup….................................................................................................................................686.3.4Documentation.....................................................................................................................686.3.4.1Comments............................................................................................................................686.3.4.2File,Date,Time.....................................................................................................................69DynoWare,Type2825A…Page52825A_002-195e-02.116.3.5EditLabels.............................................................................................................................706.3.6ResetFonttoDefault............................................................................................................706.3.7ResetColortoDefault...........................................................................................................706.3.8Zoom.....................................................................................................................................706.3.8.1ManualZoom.......................................................................................................................706.3.8.2GraphicalZoom....................................................................................................................716.3.9ZoomOut.............................................................................................................................716.3.10LockScaling...........................................................................................................................716.3.11UnlockScaling.......................................................................................................................716.3.12Horiz.Grid.............................................................................................................................726.3.13Vert.Grid..............................................................................................................................726.3.14Toolbar..................................................................................................................................726.3.15StatusBar..............................................................................................................................736.4Analysis.................................................................................................................................736.4.1MeanValue...........................................................................................................................736.4.2CursorTool............................................................................................................................746.4.3SignalDriftCompensation.....................................................................................................756.4.4Smoothingon…....................................................................................................................776.4.4.1MovingMean.......................................................................................................................786.4.4.2MovingMedian....................................................................................................................796.4.5Smoothingoff.......................................................................................................................806.4.6Filteringon….........................................................................................................................806.4.6.1LowPass..............................................................................................................................816.4.6.2HighPass..............................................................................................................................816.4.6.3BandPass.............................................................................................................................816.4.6.4BandStop.............................................................................................................................826.4.6.5FilterSetup...........................................................................................................................826.4.6.5.1EdgeFrequencies..................................................................................................................826.4.6.5.2FilterOrder...........................................................................................................................826.4.7Filteringoff............................................................................................................................826.4.8DataManipulationOffline….................................................................................................836.4.8.1Applytoallcyclesinfile.......................................................................................................846.5Tools.....................................................................................................................................846.5.1Voltmeter…...........................................................................................................................846.5.2Oscilloscope….......................................................................................................................856.6Options.................................................................................................................................866.6.1UserMode............................................................................................................................866.6.1.1Supervisor.............................................................................................................................866.6.1.2Operator..............................................................................................................................866.6.1.3ChangePassword.................................................................................................................866.7Window................................................................................................................................876.7.1Cascade.................................................................................................................................876.7.2TileHorizontal.......................................................................................................................876.7.3TileVertical............................................................................................................................876.7.4ArrangeIcons........................................................................................................................876.7.5CloseAll................................................................................................................................876.7.6<openwindowslist>.............................................................................................................876.8Help......................................................................................................................................886.8.1HelpTopics............................................................................................................................886.8.2SelectLanguage....................................................................................................................886.8.3AboutDynoWare..................................................................................................................88Content2825A_002-195e-02.11Page67.Appendix......................................................................................................................................897.1Graphs..................................................................................................................................897.2LanguageSelection...............................................................................................................907.3ShortcutKeySummary.........................................................................................................907.4ModifyingtheReportLogo...................................................................................................917.5ExampleFiles........................................................................................................................918.TechnicalDataofDAQ-SystemsType5697A..............................................................................928.1GeneralData........................................................................................................................928.2PowerSupply........................................................................................................................928.3A/DConversion....................................................................................................................928.4Connections..........................................................................................................................938.5RemoteControl....................................................................................................................939.MeasuringChainUsed................................................................................................................9410.Index............................................................................................................................................96Totalpages:97Introduction2825A_002-195e-02.11Page71.IntroductionWethankyouforchoosingaKistlerqualityproduct.Pleasetakethetimetothoroughlyreadthisinstructionmanual.Itwillhelpyouwiththeinstallation,maintenance,anduseoftheDynoWaresystem.TotheextentpermittedbylawKistlerdoesnotacceptanyliabilityifthisinstructionmanualisnotfollowedorproductsotherthanthoselistedunderAccessoriesareused.DynoWareisaneasy-to-usedataacquisitionandmani-pulationprogram.ThetypicalWindowscontrolsapplytothegraphsanddialogboxesinDynoWare.ThissectionwillgiveyouaquickoverviewofthecapabilitiesofDynoWare.ThemenubarisyouraccesstoallareasofDynoWare.Itisdividedintosectionscoveringspecificfunctionssuchasfilehandling,dataacquisitionconfiguration,hardwareconfi-guration,dataviewing,windowcontrol,andobtaininghelp.Inadditiontothemenubar,thereisatoolbarsimilartothosefoundinwordprocessingandspreadsheetprograms.Thetoolbarconsistsoficonsthatexecuteaspecificfunctionwhenclicked.Theuserhasfullcontroloverdataacquisition.Samplingrateandlengthoftrials,aswellasamplifierrangeandtriggeroptionsarealleasilyaccessible.Theunitsofdataacquisitioncanbecustomizedtothedesiredphysicaldatabeingmeasured.Thegraphsaredesignedtobeeasytoread,andcanbefullycustomized.Thenumberofgraphstoviewisflexible,alongwithdefaultparameterssoeachtrialisreadilyviewedinaformatthatismostusefultotheuser.IfyouhavequestionsatanytimewhileinDynoWare,simplypresstheF1keyandtheDynoWareon-linehelpwindowappears.Helpisalsoavailablefromthemenubar.Kistleroffersawiderangeofproductsforuseinmeasuringtechnology:Quartzcrystalsensorsforforce,torque,strain,pressure,acceleration,shock,vibrationandacoustic-emissionPiezoresistivepressuresensorsandtransmittersSignalconditioners,indicatorsandcalibratorsElectroniccontrolandmonitoringsystemsaswellasapplication-specificsoftwareformeasuringtechnologyKistleralsodevelopsandproducesmeasuringsolutionsfortheapplicationfieldengines,vehicles,manufacturing,plasticsandbiomechanics.Ourproductandapplicationbrochureswillprovideyouwithanoverviewofourproductrange.Detaileddatasheetsareavailableformostproducts.DynoWareType2825A…Page82825A_002-195e-02.111.1GettingSoftwareHelpDynoWaresoftwaretakesadvantageofanonlinehelpsystemtoofferyouquickassistance.ToreceiveimmediatehelpfromwhereveryouareinDynoWare,presstheF1keyandawindowwillpopupwithspecificadviceaboutwhereyoucurrentlyareinthesoftware.Helpisalsoaccessiblethroughthemenubarfoundatthetopofthescreen.Ifyouneedadditionalhelpbeyondwhatcanbefoundeitheron-lineorinthismanual,pleasecontactKistler'sextensivesupportorganization.Fig.1:HelpisavailablebypressingtheF1keyorbyselectingtheHelpfromthemenu1.2CustomerSupportTheworldwideKistlerserviceorganizationisavailableforanyspecialquestionsorproblemsthatyoumayhaveafteryourcarefulstudyoftheseinstructions.Note,refertosections1.3through1.6forgeneralpoliciesoncustomersupport.Beforeyoucall,pleasebereadytofullyexplainyourproblem.IfyouareexperiencingaproblemwithDynoWaresoftware,pleasetrytoduplicatetheproblemandtakeasnapshotofthescreenbypressingthe"printscreen"button.Thiscopiesthescreentotheclipboardsothatitcanbepastedintoawordprocessingprogramandprinted.YoucanemailthispicturetoKistler.Introduction2825A_002-195e-02.11Page91.3ServiceandAssistanceThecustomerisresponsibleforproperDynoWareinstallationandoperation.DynoWaremustbeinstalledasperinstructionsprovidedinsections4and5.Ifmodifi-cationstotheseinstructionsarenecessaryforaparticularpurchasersite,KistlerrecommendsthepurchasercontactaKistlerrepresentativeforinputandadviceregardingthesechanges.Installationproblemsandsubsequentsystemperformancedifficultiescanbeadvertedbytimelycommunication.Often,questionscanbeansweredthroughemailortelephoneconversations.ThepurchaserisencouragedtoemailorcalltheappropriateKistlerorganizationintheeventofsuchquestions.Wewelcomecommentsandsuggestionsforfuturefeaturesandenhancements.1.4LicenseAgreementPleaserefertotheSoftwareLicenseAgreementpacketcontainingyourDynoWaresoftwareandtothelicensepresentedduringinstallation.ThispacketthoroughlydetailstheSoftwareLicenseAgreement.YoumaypermanentlytransferthesoftwaretoanotheruserprovidedyounotifyKistlerinadvance,transferthedocumentationandalldisks,andnotifythenewuserofthetermsandconditionsofthelicenseagreement.1.5WarrantyKistlerwarrantsDynoWaretobefreefromdefectsinmaterialandworkmanshipasstatedinthesoftwarelicenseagreement.Itiswarrantedonlyundernormaluseandservice.Theperiodofwarrantyistwelve(12)monthsfromdateofshipment.Whenreturningitemsunderwarranty,saidequipmentshallbereturnedtoKistlerInstrumentsprepaid.Fulldetailsrelativetotheclaimormalfunctionshallaccompanytheshipment.Noactionwillbetakenuntilthesedetailsarereceived.PleasecontactKistleroryourKistlerrepresen-tativeforaReturnAuthorizationNumberbeforereturninggoods.SettlementwillbemadeatKistler’sdiscretion,eitherthroughrepairorreplacementoftheiteminquestionorthroughissuanceoffullcredit.DamageoccurringthroughDynoWareType2825A…Page102825A_002-195e-02.11misuseormishandling,willnotbecoveredbythiswarranty.Thiswarrantyisinlieuofallwarrantiesexpressedorimplied,andofallobligationsorliabilitiesonthepartofKistlerInstrumentsfordamagesfollowingtheuseormisuseofitemssupplied.Anyunauthorizeddisassemblyorattemptatrepairshallvoidthiswarranty.NoagentorrepresentativeisauthorizedtoassumefortheCorporationanyliabilityexceptassetforthwithinthiswarrantydocument.1.6ClaimsClaimsrelatingtogoodsdeliveredmustbemadewithin14daysofreceiptofgoods.AfterfaultdeterminationbyKistler,settlementwillbemadeeitherbythecarrier,insurer,orKistler.Meanswillbethroughreplacement,repairorcredit.ImportantInformation2825A_002-195e-02.11Page112.ImportantInformationPleasepracticecommonsensesafetyrulesatalltimes.2.1ForyourSafetyPriortoanyinstallationandrepairworkorcablechanges,youmustdisconnectallpowersourcesfromtheinstru-ments.Observealllocalsafetyregulationsconcerningthehand-lingofline-poweredelectricalandelectronicequipment.Whenitmustbeassumedthatsafeoperationisnolongerpossible,thecomputer,chargeamplifier,etc.mustbetakenoutofoperationandsecuredagainstunintentionaluse.Wheneveropeningcoversorremovingparts,exceptwherethiscanbedonebyhand,usecautionwherepartsunderhazardousvoltageareexposed.2.2WarningAnybreakageofthegroundconductorinsideoroutsidetheinstruments,orlooseningofthegroundconductorconnectionmayrendertheinstrumentdangerous.Thepowerplugmustbeinsertedintoasocketwithagroundconnector.Theprotectionmustnotbenullifiedbyanextensionlinelackingaprotectivegroundconnector.Whenchangingthesignalconditionerfuses,onlythestandardtypewiththespecifiedamperageratingmustbeused.Useofrepairedfusesorshort-circuitingthefuseholderisexpresslyforbidden.2.3HowToUseThisManualThismanualwilltakeyouthroughtheinstallationandsetupoftheDynoWaresoftware,andacompletereferencetoallofthefeaturesofthissoftware.IfyouareeagertobeginoperationofDynoWarewerecommendsection5ofthismanualforaquickstartguide.Rememberthaton-linehelpisalwaysavailablebypressingtheF1keyfromanywhereinthesoftware.DynoWareType2825A…Page122825A_002-195e-02.113.DescriptionofDynoWare3.1GeneralDynoWareisageneral-purposedataacquisitionanddisplaysoftwarepackagesuitableforcuttingforceandgeneralsensor/dynamometerapplications.DynoWareletsyouquicklysetup,record,anddisplayreactionforcesandtorques.Althoughdevelopmentconcentratedonmeasurementofcuttingforcesinmechanicalmachining,themeasurementdataacquisitionandanalysisfunctionscanalsobeusedforothermeasurementtasks.Dependingonthedataacquisitioncard,upto28channelsareavailableformeasurementacquisition.ThesoftwaresupportsdataacquisitioncardsforthePCIbus,PCcardsfornotebooksandtheUSBdataacquisitionsystemforDynoWareType5697A.Fig.2:TheDynoWaresplashscreenappearsforafewsecondswhentheapplicationstartsAllcomponentshavebeenincludedwiththesystem(i.e.,software,cables,andA/Dcard).Atypicalpiezoelectricmeasuringchainconsistsofmanycomponents,eachspecifictotheuser’sapplication.Theseinclude:DynamometerChargeamplifierDataacquisitionsystemforDynoWare(ex.Type5697AwithintegralA/DcardfromMeasurementComputingInc)DynoWaresoftwareandmanualAllnecessarycablingDescriptionofDynoWare2825A_002-195e-02.11Page133.2SystemRequirementsRecommendedComputerSpecifications:MicrosoftWindows®NT4.0(SP4),2000,XPProfessional,Vista,Windows®7(32bitand64bitversions)PentiumPC,1GHzorhigherAtleast512MBofRAMGraphicscardwithatleast800x600pixelsand256colorsAtleast100MBoffreehard-diskspaceOnefreeslotfortheA/Dcard.PCIorPCMCIATypeIIbusversionorOneUSB2.0portforDAQ-SystemType5697AAdobeReaderforprintingoutmeasurementdataColorprinter(recommended)Windows®isaregisteredtrademarkofMicrosoftCorporation.Adobe®Acrobat®Reader®isaregisteredtrademarkofAdobe.DynoWareType2825A…Page142825A_002-195e-02.114.InstallationThischapterwillshowyouhowtoinstallthedataacquisitioncard,theDynoWaresoftware,configurethedataacquisitionhardware,aswellasconnectthecablefromtheA/Dcardtothesignalconditioner.4.1DynoWareSoftwareInstallationDynoWaresoftwareconsistsofoneCD-ROMmediadiskcontaininganautomaticinstallationprocedure.ToinstallDynoWareperformthefollowingprocedure:SomeantivirussoftwarepackagescanadverselyaffecttheDynoWareinstallationprocess.Temporarilydisableyourantivirussoftwarepriortoinstallation.1.InsertDynoWareDiskintoyourCD-ROMdrive.WithmanyCD-ROMsystemstheAutorunfunctionisactivatedandthesplashroutineopenstheinstallationwindowautomaticallyassoonastheCD-ROMisrecognized.Inthiscaseyoucangostraighttostep4.2.(IfyourCD-ROMissetuptoautoplayyoucanskipthisstep.)FromtheStartmenu,chooseRun,inthedialogbox,type"d\:kistlersetup"(withoutthequotes)substituteyourCD-ROMdriveletterfor"d"above,chooseOK.3.The"kistlersetup.exe"programpresentsgeneralinformationoninstallingDynoWare.Werecommendreadingthisinformationpriorcontinuation.Theop-tionspresentedareto"BrowseTechnicalNotes","BrowseDocumentation","ViewSystemRequire-ments"and"InstallDynoWareSoftware".4.WhenreadytoinstallDynoWare,selectthe"InstallDynoWareSoftware"option.5.Followtheonscreeninstructions.Fig.3:StartSetupprogramInstallation2825A_002-195e-02.11Page15AlternativemethodofinstallationAnotherwayofinstallingtheprogramifitisnotstartedautomaticallyistomanuallyclickthefile'kistlersetup.exe'intherootfolderoftheCD-ROM.Theinstallationwindowisopenedandyoucangostraighttostep4.Thefirstinstallationscreenwillpresentyouwithachoiceofthedefaultlanguage.YoucanswitchtheuserlanguageofDynoWareatanystageofoperation.ThenyouwillbepresentedtheLicenseAgreement.Confirmingacceptancedisplaysthereadmeanduserinformation,andthedestinationfolderforprogramsanddatacanbespecified.TheSetupTypedialogallowsyoutochoosebetweenCompleteandCustominstallation.Normally,SetupTypeshouldbesetto"Complete"TheSetupType"Complete"willinstalltheDynoWareapplication,theHASPRuntimeLicenseDrivers,thedriverofthedataacquisitionsystemandthedriveroftheUSBinterfacestotheconnectingboxType5697A.Wealwaysrecommendtoinstallthe"complete"versionofthissoftware.Pressing"Install"startstheactualinstallation.Followtheinstructions.Finally,toapplythedriversthePCmustberestarted.DynoWareType2825A…Page162825A_002-195e-02.114.2HASPKeyInstallationWithoutahardwarekeyor"dongle"DynoWareonlystartsinthedemonstrationmode.Thedongle(HASPkey,runtimelicense)isneededtoacquiredataandexploitthevariouspossibilitiesofferedbyDynoWare.Thisdongleistheonlywayoflegitimizingthesoftware.Installtheruntimelicenseasfollows:1.AfterinstallingDynoWareinsertthedongleinafreeUSBportonyourcomputer.Therelevantdriversareinstalledautomatically.IfyouareusingtheDAQ-SystemType5697Ayoucangostraighttosection4.3.3.Installation2825A_002-195e-02.11Page174.3InstallingDataAcquisitionCardThedataacquisitioncardshouldbeinstalledbysomeonewhoisfamiliarwithinstallinginternalcomputerperipherals.Ifyouareunsurehowtoopenyourpersonalcomputerorifyoursystemiswarrantedunderaservicecontract,pleasehaveaqualifiedtechnicianinstallthecard.TheinstallationCD-ROMcontainscardspecificInstallationTechnicalNotesforthevariousA/DcardsuppliedbyKistler.Seethesetechnicalnotesaswellastheinformationbelow.TheproceduretoinstallandconfigurethecardishighlydependentonthespecificcardpurchasedwithDynoWare.Makesuretodisconnectthepowersourcefromyourcomputerbeforeopeningit.ProtectthesystemandA/DcardfromstaticdischargebytouchingthecomputerchassistogroundyourselfpriortohandlingtheA/Dcard.4.3.1PCIM-DAS1602/16ThefollowingstepsarerecommendedforA/Dcardinstallation:MakeabsolutelysuretotakenoteofthetechnicalinformationinthefileK20.302-4ePCIM-DAS1602.pdfontheinstallationCDbeforeinsertingthePCIM-DAS1602/16card.1.Withthepoweroffandthepowercordunplugged,removethecomputerPCcovertogainaccesstothesystem'sexpansionslots.Avoidtouchinganycompo-nentsinsidethePC.2.TouchthemetalcomputerchassispriortohandlingtheA/Dcardtoavoidinducingstaticshocks.3.Settheon-boardswitchtoBIP(bipolar)(seeyourcardmanual).4.Settheon-boardswitchto8channels(differential).5.SelectanavailablePCIslot,andremovethebackplatemetalcoverswithascrewdriver.DynoWareType2825A…Page182825A_002-195e-02.116.CarefullyinserttheA/Dcardintotheslotmakingsurethatitseatscorrectlyintothecomputer.Replacetheslotcoverscrew,fasteningtheedgeofthecardtothechassisofthePC.7.WiththeA/Dcardproperlyinstalled,replacethecoverofthecomputerandtightenthescrews.8.Restartthecomputer.Thecardwillbeauto-detectedbytheplug-and-playoperatingsystem.Ifpromptedforthedriver,inserttheDynoWareCD-ROMcontainingtheCBI95.INFfile.9.Followtheinstructionsinsections4.4.1.4.3.2PC-CARD-DAS16/16ThefollowingstepsarerecommendedforA/Dcardinstallation:MakeabsolutelysuretotakenoteofthetechnicalinformationinthefileK20.302-6ePC-CARD-DAS16.pdfontheinstallationCDbeforeinsertingthiscard.1.EnsureDynoWareisfullyinstalled(see4.1).2.WiththepoweronandWindowsrunning,insertthePC-CARD-DAS16/16intoaPCMCIAtypeIIslot.3.Windowswillrecognizethisdeviceasanewdeviceandwillpromptyoutoenterthediskwiththemanufacturer'sdrivers.ThisistheCD-ROMwiththeDynoWareinstallationprogramandcontainingthefileCBI95.INF.Insertthediskintothedriveandcon-tinue.4.WindowswillloadthenecessaryPC-CARDdriversandconfigurethePC-CARD-DAS16/16.5.Followtheinstructionsinsection4.4.2Installation2825A_002-195e-02.11Page194.3.3Type5697ADAQ-SystemforDynoWare(USB2533)ThefollowingprocedureisrecommendedforinstallingtheA/Dcard:MakesuretotakenoteofthetechnicalinformationinthefileK20.302-11eType5697DAQ.pdfontheinstallationCDbeforeinsertingthiscard.1.EnsureDynoWareiscompletelyinstalled(seesection4.1).2.PowerupthedataacquisitionsystemwiththeswitchintheOFFposition.Theouterringoftheconnectormustbetightenedclockwisebeforehand.3.ConnecttheacquisitionsystemtothePCwiththeincludedUSBcable.4.InserttheUSBruntimelicensedongle(HASPkey)intothematchingslotinthedataacquisitionsystem.5.SwitchthedataacquisitionsystemforDynoWareon(ONposition)afterstartingtheWindowsoperatingsystem.6.Windowsdetectsthedeviceandinstallsitsdrivers.IfWindowsissearchingfordrivers,inserttheDynoWareinstallationCD-ROMthenfollowtheinstructions.7.WindowsloadstherequireddriversandconfiguresthemfortheDataAcquisitionSystemType5697A.8.Followtheinstructionsinsection4.4.3.Oldercardscanbeactivatedmanually.WhenevertheDAQ-SystemType5697Aisremovedfromthecomputerandreconnected,orswitchedoffandonagain,INSTACALmustbestartedtoallowloadingofthenecessarydrivers.DynoWareType2825A…Page202825A_002-195e-02.114.4A/DCardConfigurationThesoftwareconfigurationprocessinvolvestwosteps.InthefirstthecardanddataacquisitiondriversareconfiguredwithINSTACAL.Thisrequirescertainroutinesfromthemanufactureroftheacquisitioncard.InasecondstepthissetupmustbeexportedtoDynoWare.INSTACALcanbestartedundertheMeasurementComputinggroupofprograms.TheprogramconfiguresthedriverandA/Dcardsetupforyou.LookfortheMeasurementComputinggroupofprograms(Startmenu(All)Programs)andchoosetheInstacalicon.Fig.4:InstacalboardconfigurationprogramTheInstacalcardconfigurationprogramwillauto-maticallyidentifyandplug-and-playcapabledataacquisitioncards.Manuallyaddanynonplug-and-playcards.SelectingtheInstacalprogramCalibratemenuoptionwillreconfigurethecard'sfactorycalibratedparametersandaffecttheaccuracyofyourmeasurements.DoNotruntheCalibrationroutine.Instacalwillautomaticallyidentifyanyinstalledplug-and-playcards.Anynonplug-and-playcardwillhavetobemanuallyaddedbyselectingtheInstallmenuoptionandthenselectingthedesiredcardfromthelist.Instacalshouldberunanytimeacardisremovedfromacomputer(evenforPCMCIAcards).Fig.5:ConfigurationforthePCIM-DAS1602/16DynoWarewillusethecardconfiguredinInstacalasboardzero.Bydefault,the"DEMO-BOARD"isinstalledasboardzero.Removethe"DEMO-BOARD"andreconfigurethedesiredcardtobenumberzero(Seesection4.5).ThisappliestoalloftheA/Dcardslistedhere.Installation2825A_002-195e-02.11Page21Oncethecardisinstalleditwillneedtobeconfigured.RightclickonthecardandselectConfigure…ordoubleclickthecard.4.4.1PCIM-DAS1602/16SeetechnicalnoteK20.302-4ePCIM-DAS1602.pdfcontai-nedontheinstallationCD-ROMfordetailedinformation.Thefollowingparametersshouldbeset:ChannelsSelect8channels,differentialmode(note:Instacalsettingmustmatchhardwareswitchsetting).InputModeBipolar(note:Instacalsettingmustmatchhardwareswitchsetting).ClockSpeedSelect10MHz(note:Instacalsettingmustmatchhardwareswitchsetting).4.4.2PC-CARD-DAS16/16SeetechnicalnoteK20.302-6ePC-CARD-DAS16.pdfcon-tainedontheinstallationCD-ROMfordetailedinfor-mation.Thefollowingparametersshouldbeset:ChannelsSelect8-channeldifferentialmode(note:Instacalauto-maticallycontrolshardwaresetting).InputModeBipolar(note:Instacalautomaticallycontrolshardwaresetting).ClockSpeedSelect10MHz(note:Instacalautomaticallycontrolshard-waresetting).DynoWareType2825A…Page222825A_002-195e-02.114.4.3Type5697ADAQ-SystemforDynoWare(USB2533)SeetechnicalinformationK20.302-11eType5697DAQ.pdfontheinstallationCD-ROMformoredetailedinformation.Thefollowingvaluesmustbeset:ChannelsChoose64channels,single-endedmode(note:Instacalautomaticallycontrolsthehardwaresetup).Ifthecardisnotsetto64channelssingle-ended,thefollowingmessageisdisplayedwhenDynoWareisstartedup:DynoWareautomaticallyswitchesto64channelssingle-ended.4.5SetCardNumbertoZeroDynoWareoperatesusingtheInstacalcardconfiguredascardnumberzero.Bydefault,"DEMO-BOARD"isinstalledascardnumberzero.Rightclickthecardzero"DEMO-BOARD"andselecteitherDelete(toremoveitcompletely)orChangeBoard#toreconfigureitatadifferentcardnumber.ThenRightclickthedesiredcardandselectChangeBoard#toreconfigureitasBoardzero.YourcardisnowproperlyconfiguredtooperatewithDynoWare.TheA/Dbits,Availablechannels,AcquisitionmodeandMaximumChannelswillbeautomaticallysetreflectingthecardtypeselected.ThegaincanbeselectedinDynoWaretoyourspecifications.Thegainsettingchangesthescaleonthecarditself,sothelowerthescalemeansthebettertheresolution.However,italsomeansaloweroverallmeasurementforcerange,sotheusermustbecarefulnottochoosetoohighofagainsuchthatsaturationoccurs(i.e.,besuretheforcestobemeasureddonotexceedthemeasuringrangeofthesystem.Ifthisoccurs,choosealowergainsuchas10V).Installation2825A_002-195e-02.11Page234.6RunningDynoWareTorunDynoWare,opentheKistlerGroupintheProgramsextensionoftheStartMenuandclickontheDynoWareicon.Itispossibletochangetheprogramlanguage,seesection7.2.4.7ConnectingtheMeasurementSignalCable("AnalogInput")4.7.1PCIM-DAS1602/16andPC-Card-DAS16/16Thereisone(1)37-pincablethatconnectsthejunctionboxoramplifiertothedataacquisitioncard.Toproperlyconnectthecable:1.Shutdownthecomputerandturnoffthepowertothecomputerandtheamplifier.2.Connectthe37-pincablefromtheA/Dcardtothejunctionboxoramplifier.3.Besuretotightenanycable-fasteningscrewsbyhandtosecurethecableconnectionsandpreventslippage(donotovertighten).4.Turntheamplifierandcomputeron.Ifthecablesarenotlongenough,additionalcablescouldbeconnectedtotheoriginalonestoextendtheirlengths.Excessivelylongcablesarenotrecommendedbecauseinsulationmaynotbeadequatetopreventinterferenceandlossofsignal.DynoWareType2825A…Page242825A_002-195e-02.114.7.2Type5697ADAQ-SystemforDynoWareDAQ-System,Type5697A,withDynoWareallowsforacquisitionofupto28channelssimultaneously,byusingboth"AnalogInput"connections.Fig.6:ConnectionsonDAQ-SystemType5697AA15-polelow-resistancemeasurementsignalcableType1700A111A2ortype1700A113A2connectstheconnectingboxoftheDAQ-SystemforDynoWareType5697Atothechargeamplifierorsignalconditioner.Connectthecableasfollows:1.Switchtheconnectingboxandtheamplifierorsignalconditioneroff.2.Connectthe15-polecableType1700A111A2fromtheconnectingboxtotheconnectorboxortheamplifier.3.Tightenthescrewsontheconnectortosecuretheconnections(however,toavoiddamagingthethreaddonotovertighten).4.Switchamplifierandconnectingboxon.Installation2825A_002-195e-02.11Page254.8ConnectingRS-232CInterfaceCableARS-232CinterfacecableType1200A27orType1475A3(seesection9)isrequiredtocontrolthechargeamplifierorsignalconditioner.IftheA/DcardPCIM-DAS1602/16orPC-Card-DAS16/16isbeingusedthisconnectionismadedirectlytothePCornotebook,iftheDAQ-SystemType5679Aisbeingemployeditismadedirectlytotheconnectingbox.4.8.1ConnectingtoPC/NotebookIfthereisanRS-232CinterfaceonthePCornotebook,thecorrespondinginterfacecable(seesection9)isconnecteddirectlytothenotebook.NotebooksinparticularoftennolongerhaveanRS-232Cport,andthereforehavetobeusedwithaUSB-RS-232Cconverter.WerecommendalsopurchasingthisadapterfromKistler(Type2867).Whenusingsuchanadapteralsoensurethematchingsoftwareisinstalled.4.8.2ConnectingtoConnectingBoxType5697ATheconnectionbetweensignalconditionerorchargeamplifierandDAQconnectingboxisalsomadewithanRS-232Ccable.ThisisconnecteddirectlytotheRS-232CofChannel1ontheconnectingbox.DynoWareisnotcapableofcontrollingtwochargeamplifiersortwosignalconditionersviaDAQ-SystemType5697A.DuetothatitisnotrecommendedtousebothRS-232Cconnectorsinparallel.Toavoidcommunicatingcomplications,eithertheRS-232Cconnectorof"UnitA"orof"UnitB"shouldbeusedtoconnecttheamplifier.DynoWareType2825A…Page262825A_002-195e-02.11TheusedCOM-portsofthetwoserialinterfacesofDAQ-SystemType5697AcanbefoundintheDeviceManagerofWindows.ForthecaseshownbelowtheserialportofUnitAisonCOM7,theserialportofUnitBonCOM8.COMxhastobedefinedintheHardwaresettings(seechapter6.2.1)tocommunicatewithchargeamplifiersorsignalconditioners.Installation2825A_002-195e-02.11Page274.9UsingRemoteControlInterfaceonDAQ-SystemType5697AThemeasuringchaincanbetriggeredviathe'RemoteControl'interfaceontheDAQ-SystemType5697.Thisispossiblewith,forexample,theinductiveproximityswitchType2233BfromKistler.Thepinallocationistobefoundinsection8,thenecessaryDynoWaresetupinsection6.2.2.2.4.10ImportantIssuesRegardingPiezoelectricDynamometersPleasetakecaretofollowtheserulesapplyingtoinstal-lationandhandlingofdynamometersandconnections:Protectthesignalconditionerandcableconnectorendsfromdustandmoisture.Closeendcaps.Dynamometermountingsmustbelevelandproperlysecured.Usecautionconnectingandremovingthecables.Alsotakecaretonotsteponthecableconnectionstoavoidshearingoffthecable.4.11ChargeAmplifiersDynoWareautomaticallycontrolstherangeselection,filterselectionandoperate/resetfunctionsofseveraltypesofKistlerchargeamplifiers.Chargeamplifiersshouldbeallowedtowarmupsufficientlyformostaccuratemeasu-rements,with30minutesbeingaminimum.Unplugtheamplifierifitisnottobeusedforaverylongtime.DynoWareType2825A…Page282825A_002-195e-02.115.QuickStartThissectionwillhelpfamiliarizethenewuserwithDynoWare.Datacannotbeacquireduntilthehardwareisproperlyconfigured.ThissectionismeantasanoverviewtothefeaturesofDynoWarethatwillbeappliedtoacquiredtrialsandgraphsoncetheproperconfigurationshavebeenperformed.FormoreinformationonconfiguringDynoWare,refertosection6.2.Fig.7:RunningDynoWarefromtheStartmenuStartDynoWarebychoosing:Start(All)ProgramsKistlerDynoWareDynoWare.Thesplashscreenappearsbrieflyandshowscurrentapplicationversionandproducttypeinformation.Fig.8:DynoWare"SplashScreen"TheFilemenuallowsyoutoopenstoredtrials,print,save,export,manageconfigurationsandexittheprogram.Theprintsetupcanbecustomizedherealso.Feelfreetoopensomeofthesuppliedtrials(bydefault:C:\Kistler\DynoWare\Data)andmanipulatethemtohelpfamiliarizeyouwiththeprogram’scapabilities.QuickStart2825A_002-195e-02.11Page29TheAcquisitionmenuiswherehardwareisconfiguredandwheredataacquisitionisperformed.ChoosingAcquisitionHardwarewillbringuptheHardwareDialogBox(Fig.9)showingtheconfigurationsettings.ChoosingAcqui-sitionSetupallowstheusertoconfiguredataacquisitionspecificparameters(Fig.10).AcquisitionStartwillbegintheacquisitionprocess.Fig.9:HardwaresetupdialogboxFig.10:EditAcquisitionTheViewmenuallowstheusertoconfigureDynoWaregraphicpreferencesandtoeditthetrialdocumentation.SelectingViewSetup(section6.3.3)allowsconfigura-tionofthedefaultgraphsthatappearwhenafileisopenedoratrialisacquired.WithViewEditthecontentofanindividualgraphcanbechanged.DynoWareType2825A…Page302825A_002-195e-02.11Doubleclickingonaspecificfeatureofthegraph(title,legendoraxistitle)provideseditingcapability.Theviewcanbechangedatanytimewithoutadverselyaffectingthedatainanyway.Ausermayalsozoomthedisplayedarea,enable/disablegridlines,displayamovingcursor,andeditlabelsanddocumentationinformationfromtheViewmenu.Fig.11:ViewEditTheAnalysismenugivesoptionsforsmoothingorfilteringdata,statisticoptionsanddatamanipulation.TheToolsmenuprovidestwomethodsfordisplayingreal-timevoltagedata:OscilloscopeandVoltmeter.Thesetoolsaredesignedforsimpletroubleshootingofthesystem.TheothermenuthatappearswhenagraphisshownistheWindowmenu.TheWindowmenuusesstandardMicrosoftWindowscommandstoarrangeactivewindows.Reference2825A_002-195e-02.11Page316.ReferenceThissectiondescribesthemenususedinDynoWare.6.1File...Dependingonwhetherornotagraphisopenonthescreen,theFilemenuwillhaveadifferentappearance.Ifnographisopen,therewillonlybecommandstoOpen,Configuration,ExportandExitDynoWare.6.1.1Open…Thiswillbringupafileopendialogboxwherethedesiredtrialcanbeselectedforviewing.Thedefaultdirectoryisthedatadirectory,thoughthedialogboxcanbeeasilynavigatedusingstandardWindowstechniquestobrowseotherdrives,directories,andnetworkcomputers.Theextensionforthetrialsare"*.dwd".FilesstoredinDynoWare1.xformatwillautomaticallybeconvertedandloaded.Ifavalidconfigurationfileexists,theLoadConfigurationFilecheckboxwillbeavailableandtheusercanchoosetoloadtheconfigurationoptionsassociatedwiththefile(hardwaresetup,dataacquisition,andviewsetups).Ifaconfigurationwasnotstoredforthedatafile,thisoptionwillbedisabledandappeargrayedout.6.1.2SavemodifiedfileTheoperationsSmoothingon(seesection6.4.4),Filteringon(seesection6.4.6)andSignalDriftCompensation(seesection6.4.3)displaytemporarychangestoadataset.Theseoperationsdonotpermanentlyaffectthedatastoredinafile.Topermanentlyarchivethesechanges,selectSavemodifiedfilefromtheFilemenu.Thisoperationallowstheusertoapplyseveraldifferentfunctionstoadataset.Forinstance,datacanbecompen-satedfordrift;thechangessaveinthefile,andthenMeanvalueanalysiscanbedone.Normallythedriftcompen-sationandmeanvaluefunctionsaremutuallyexclusive(cannotbedoneatthesametime).DynoWareType2825A…Page322825A_002-195e-02.11Overwrittenchangescannotbeundoneandperma-nentlymodifythedatainthefile.Theoriginaldatafilewillbesavedas"*.bak.dwd".6.1.3Configuration...TheHardware,DataAcquisitionandViewsettingscanbeloadedorstoredtoafile.Thedefaultextensionforconfigurationfilesis"*.cfg".6.1.3.1Load…ToloadtheHardware,DataAcquisitionandViewsettingsfromaconfigurationfileselectConfigurationLoad.ThiswilloverwritetheexistingDynoWareconfigurationset-tings.AstandardWindowsfileopendialogbox(seeFig.12)willbepresentedtoselecttheappropriateconfigurationfiletoload.ToloadaconfigurationfileautomaticallywhenadatafileisopenedenabletheLoadconfigurationfileoptionintheFileOpendialogbox(Seechapter6.1.1).Fig.12:ConfigurationLoad6.1.3.2Save…TostoretheHardware,DataAcquisitionandViewsettingstoaconfigurationfileselectConfigurationSave.Astand-ardWindowsfilesavedialogboxwillbepresentedtoselecttheappropriateconfigurationfilenametosavethecurrentsettings.Thedefaultextensionofconfigurationfilesis"*.cfg".Configurationfilescanbesavedauto-maticallybycheckingtheSaveconfigurationoptionintheAcquisitionEditdialogbox.Reference2825A_002-195e-02.11Page336.1.4Export…FilesmaybeexportedtoASCIIdelimitedtextfilesbyselectingFileExport(e.g.forfurtherevaluationinMicrosoftEXCEL).TheExportDialogallowsfortheselectionofthecyclestoexport,andthechannelstoexport.AllmeasurementsareexportedwithEverysample.ThesettingEveryn-thsampleresultsinonlyeveryn-thmeasurementbeingexportedandtheintermediatemeasurementsbeinglost.ThesettingExportmeanvalueofgroup(ofnsamples)resultsinthemeanofnmeasurementsbeingexportedratherthanindividualmeasurements.Valuesfrom2to100canbeenteredforn.TheoptionExportpartialtimeintervalexportsdataofadefinedtimeframe.TheoriginalDynoWarefileisnotchangedbysuchdatareduction;itisjustthatfewerdatapointsareexported.ThissimplifiesimportationofExcelspreadsheets,whoserowcountislimitedto65000.Fig.13makesitpossibletoselectwhichchannelsandwhichmeasuringcyclesaretobeexported.Theusercanchoosethedatadelimiterorenteroneoftheirown.IfCommaischosenasaseparatortheextensionofthefileischangedto“*.csv”automatically.Thedestinationoftheexportfilecanbechosenbyselecting…inFig.13.ToexportdataconfirmsettingswithOK.Anewboxisdisplayedtoshowprogress.Anexampleofanexportedfileisshownbelow.UsetheSelectAll/UnselectAllonFig.13buttonstoselecttherequiredchannelsandmeasuringcyclesfaster.DynoWareType2825A…Page342825A_002-195e-02.11Fig.13:ExportdialogboxTip:UsingtabsasdelimitersallowstheexportfiletobeopeneddirectlyinMicrosoftExcel.DynoWareusestheAmericannumberformatwithaperiod"."asdecimalseparatorandcommasymbol","fordigitgrouping.IfthecountrysettingfornumbersonControlPanelissetotherwiseproblemscanarisewhentheexportfileisopenedinExcel,assomenumberswillbereadasdate.Reference2825A_002-195e-02.11Page35Exampleofanexportedfile:FILETYPE:Path:C:\DynoWare_Data\IPL-Tagung\Filename:5A-Fraesen_Aussen_2.dwdConfigID:5A-Fraesen_Aussen_2.cfgSetupID:0Manipulated:0Filename1:Filename2:Date:Monday,12September,2000Time:13:43:19Samplingrate[Hz]:3000Measuringtime[s]:90Delaytime[s]:0Cycletime[s]:0Cycles:1Samplesperchannel:270001Cycleinterval:0Channelenabled:11CycleNo:1Time[s]FzMz0-2.832032.44E-033.33E-04-3.11523-4.88E-036.66E-04-3.11523-2.44E-031.00E-03-3.11523-2.44E-031.33E-03-2.83203-2.44E-031.67E-03-2.54883-2.44E-03.........2.67E-03-2.54883-2.44E-036.1.5Print...Shortcut:Ctrl+PPrint…bringsupthePrintdialogbox(Fig.14)usingthedefaultprintsettings.Theuserselectstheviewstobeprintedbyclickingontheviewsinthelist.TheDocumenttitleappearsasthedefaultgraphtitlebuttheusercanchangethetitlehere.PressingtheSelectAllbuttonwillselectallopenviewstobeprinted.PrintAcquisitionandHardwareInformationenablestheprintingoftheAmplifierandAcquisitionconfigurationatthebottomoftheprintout,previewingtheprintoutonscreenpriortomakingahardcopy,andprintingtoafileforlaterviewing.SomeprintoutinformationwillbedisablediftheselectedviewcontainsMultiplecycledata.Fig.14:PrintdialogFileDataFileHeaderInformationFileHeaderInformationDynoWareType2825A…Page362825A_002-195e-02.11AfterselectingOK,thePrinterselectiondialogwillappearallowingtheusertochangetheprinterandselectthenumberofcopiestoprint.IfthePreviewoptionwascheckedtheprintpreviewscreenwillappear(seesection6.1.6).Fig.15:Printerselection6.1.6PrintPreview…ThePrintPreview…isidenticaltothePrintfunctionaboveexcepttheoutputappearsonthemonitor.Thisallowstheusertoseewhattheprintoutwilllooklikeonthepriortoprintingsothatanynecessarychangescanbemadebeforetheprintfunctioniscarriedout.Fromthisdialogboxyoucanzoominontheimageforacloserlook,createaprintfile,directlyemailaprintfileandexecutethehardcopyPrintfunction.Aprintfileisaspecial"*.ll"filethatcanbeviewedwithaspecialviewer.Thespecialviewer,LLViewer,isavailableontheinstallationCD-ROMintheLLViewersubdirectoryorintheinstallationdirectory–bydefaultC:\Kistler\Dynoware\.RuntheLLView.exeinstallationprogramandfollowtheonscreeninstructions.FilesdirectlyemailedwillneedtheLLViewertoviewtheemailcontents.Reference2825A_002-195e-02.11Page37Fig.16:PrintpreviewDynoWareType2825A…Page382825A_002-195e-02.116.1.7PrintSetup…PrintSetup…allowstheusertoconfiguretheprintingspecifications.Standardsetupfunctionsaretoselecttheprinter,papersizeandtray(ifapplicable),andthepaperorientation.APropertiesbuttonallowsfurthercustomizingofprintersettings.6.1.8CopytoClipboardThiswillcopytheactivewindowcontentstotheWindowsclipboard.Thegraphcanthenbepastedintoawordprocessingorspreadsheetapplicationasagraphic.6.1.9ExitExitclosesDynoWare.Sincechangestothedataarecontinuouslystoredinthefile,noextraquestionisneces-saryaboutsavingchanges.6.2AcquisitionTheAcquisitionmenuiswherealldataacquisitionandhardwareconfigurationisperformed.6.2.1Hardware…Shortcut:Alt+HFig.17:HardwareconfigurationReference2825A_002-195e-02.11Page39TheHardware…dialogboxallowstheusertocustomizespecificequipmentusedinthesystem.Thedialoghasseveraldifferenttabsdependentuponthespecificamplifierconfiguredinthesystem.Thereareuptofourmajoritemsthatcanbeconfigured:TheA/Dcard,theamplifierandthedynamometerplusforce&torquecalculationandcommunicationinterfacesettingsspecifictoanamplifier.6.2.1.1A/DCardTheA/DcardisautomaticallyselectedfromtheINSTACALboardconfigurationprogramfromMeasurementComputing(seesection4.4).ThistabshowstheconfiguredA/Dcard(boardinInstacal)andallowstheusertoedittheA/Dboardgainselection(A/DBoardFullScalemeasurementrangeinvolts).Fig.18:A/DcardsetupInformationdisplayedis:BoardDisplaystheA/DcardthatisconfiguredintheINSTACALprogram.FullScaleTheA/DBoardFullScaleinputdefinestheresolutionoftheA/Dcard:SmallFullScale=moreresolutionpervolt,Note:AllinputvoltagesignalstothecardmustbesmallerthanthedefinedFullScale.BurstModeNormally,thesamplingclockrunsat1/(samplerate*numberofchannels).Thisresultsinsomefixedlatencyinsamplingtimebetweenindividualchannels.Tominimizelatency,BurstModeallowseachchannelbanktobescanned/sampledatthefullrateofthecard.Example:Sampling2channels@50Hz,max.throughput100kHz.NonBurstModeChanneltoChannellatencytime=1/(50*2)=0,01s=10,0msBurstModeChanneltoChannellatencytime=1/(100000)=0,000001s=0,01msDynoWareType2825A…Page402825A_002-195e-02.11Whenburstmodeisenabled,thesystemcloselyapproximatesSimultaneousSampleandHold.IfthePC-CARD-DAS16/16isbeingused,DynoWaredisablestheburstmodefordatathroughputsgreaterthan33kHz,asthiscardcannotbeoperatedintheburstmodeatsuchhighrates.IftheDAQ-SystemType5697Aisbeingused,DynoWareautomaticallyenablestheburstmodewithoutanynecessityforadditionalsettings.DescriptionDescriptionoftheA/Dcardmanufacturer.Max.ThroughputDisplaysmaximumthroughputoftheA/Dcard.ResolutionDisplaysresolutionoftheA/Dcard.AnalogChannelsDisplaysthemaximumnumberoftheanalogchannelsavailable.DigitalChannelsDisplaysthemaximumnumberofthedigitalchannelsavailable.6.2.1.2ShowHardwareDialogbetweenAcquisitionCyclesIfenabled,thehardwaredialogwillappearpriortoacquiringdataforacycle.Thecheckboxenablesordisab-lesthisoption.Onlychangestotheamplifiersettings,andoperate/resetstateareallowedafterswitchingtothedataacquisitionmode.SelecttheAcquisitionHardwareoptiontore-enablethisoption,ortomakeextendedchangestotheconfiguration.6.2.1.3AmplifierSelectionTheusershouldfirstchoosetheamplifierselectionfromthebottomofthedialog,SupportedamplifiersaretheType5017/5019,Type5011/5015,Type5018,SignalConditionerType5223toRCDType9123…and9124…,SignalConditionerType5237forHS-RCDType9125A…,SignalConditionerType5238andAmplifiersType5070and5080.TheentryOthersoffersafreechoiceforotheramplifiers.Fig.19:AmplifierselectionReference2825A_002-195e-02.11Page416.2.1.4ConfigurationsusingAmplifierType5017/5019Selecting5019/5017intheamplifierselection(seesection6.2.1.3)willenablethemultichannel5017/5019tab,theRS-232CSetuptab,andtheMulticomponentMeasurementtab.6.2.1.4.1MultichannelAmplifierType5017/5019Themultichannelconfigurationtaballowsforcustomi-zationofType5017or5019multichannelchargeamplifier.Thereareseveralconfigurableparametersassociatedwiththisamplifier:ChannelChannelnumberdisplaysthespecificchannelnumberrangingfrom1upto8.LabelEnteranylabelforeachchannel.Thislabelwillappearongraphsandreports.MeasuringRangeEntertheMeasuringRange(Maximummeasurableamount)[M.U.]ofeachchannel(M.U.=MechanicalUnit).UnitEnterthedisplayunitsofeachchannel.ScaleTheScalesettingfortheamplifierisautomaticallydeterminedfromtheMeasuringRangeandthefullscaleoutputcapabilityoftheamplifier.Scale[M.U./V]=MeasuringRange[M.U.]/10,0VSensitivityEnterthesensitivityofasensor(seecalibrationsheet).FilterSelectthedesiredlow-passfilter(internalfilterinthesignalconditioner)tobeused.TimeConstantSelectthedesiredTimeConstant(internalhigh-passfilterinthesignalconditioner)tobeused.MeasureTransmitthecommandtoplacetheamplifierintothemeasure(operate)mode.ResetTransmitthecommandtoswitchtheamplifiertoresetmode.SendParametersTransmitthecommandtosettheappropriateperchannelconfigurationforSensitivity,Range,Filter,andTimeconstantsettings.Reset/OperateEnableautomaticcontrol(viaRS-232Cinterface)oftheOperate/Resetcommandsduringatypicalacquisitioncycle.Amplifierwillbeautomaticallysettooperateatthestartofacycle,andwillreturntoresetaftertheacquisitionhascompletedforanygivencycle.Insomecases,thisautomaticcontrolofReset/Operateisnotdesiredandtheselectionboxshouldremainunchecked.6.2.1.4.2RS-232CSetupTheRS-232CconfigurationmustbeproperlyconfiguredusingtheRS-232CSetupTabforType5017or5019tofunctionproperly.DynoWareType2825A…Page422825A_002-195e-02.11SerialPortSelectstheCOMportusedtocontrolthesignalconditioner.ThisistheportonthePCtowhichtheserialcableisconnected.BaudRateSelectsthedatatransmissionrateusedtocommunicatewiththesignalconditioner.Thissettingmustbeidenticaltothesettinginthesignalconditioner.Refertothesignalconditionermanualtodeterminethepropersetting.DataBitsSelectsthenumberofdatabitsusedinthedatacommunicationprotocol.Thissettingmustbeidenticaltothesettinginthesignalconditioner.Refertothesignalconditionermanualtodeterminethepropersetting.StopBitSelectsthenumberofstopbitsinthedatatransmissionprotocol.Thissettingmustbeidenticaltothesettinginthesignalconditioner.Refertothesignalconditionermanualtodeterminethepropersetting.ParitySelectstheparitycheckingusedduringcommunicationwiththesignalconditioner.Thissettingmustbeidenticaltothesettinginthesignalconditioner.Refertothesignalconditionermanualtodeterminethepropersetting.HandshakingSelectsthehandshakingmethodusedduringcommunica-tionwiththesignalconditioner.Thissettingmustbeidenticaltothesettinginthesignalconditioner.Refertothesignalconditionermanualtodeterminethepropersetting.TypicallythecommunicationisconfiguredforCOMx,9600baud,8databits,1stopbit,noparity,andnohandshaking.Seechapter4.8tofigureoutwhatCOM-portiscurrentlyused.6.2.1.4.3Force&TorqueCalculationWiththemultichannelAmplifierType5017andtheappropriatehardware,additionalsoftwarecalculationscanbeperformed.Thesecalculationscanprovideresultantforcesandtorquesforvarioustypesofdynamometers,inavarietyofapplications.Ifamultichannelcalculationisenabled,theusercannolongerenable/disablechannelsintheconfiguration(Section6.2.2.2).SelecttheMulticomponentModecalculationtypefromthelistpresentedcorrespondingtoyourspecifichardwaredynamometer.Reference2825A_002-195e-02.11Page436.2.1.4.3.1ModeOffForce&Momentcalculationsaredisabled.6.2.1.4.3.2Type1Thetype1dynamometermeasures4shearcomponentsand1verticalcomponent.FromtherawcomponentsFx,Fy,FzandMzarecalculated.Theusermustconfigurethea1,a2,b1,andb2distances.6.2.1.4.3.3Type1aThetype1adynamometermeasures4shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMzarecalculated.Theusermustconfigurethea1,a2,b1,andb2distances.6.2.1.4.3.4Type2Thetype2dynamometermeasures2shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,Myarecalculated.Theusermustconfigurethedistancesaandb.DynoWareType2825A…Page442825A_002-195e-02.116.2.1.4.3.5Type3Thetype3dynamometermeasures4shearcomponentsand2verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,Mzarecalculated.Theusermustconfigurethedistancesaandb.Thetype3dynamometerisforType9265C...only.6.2.1.4.3.6Type4Thetype4dynamometermeasures4shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,My,Mzarecalculated.Theusermustconfigurethedistancesaandb.6.2.1.4.3.7Type5Thetype5dynamometermeasures5shearcomponentsand3verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,My,Mzarecalculated.Theusermustconfigurethedistancesa,bandc.Reference2825A_002-195e-02.11Page45SensorDistancesEnterthedistancesbetweensensorsfromthedrawinggivenfortheappropriatedynamometertype.Alldistancesareenteredinmillimeters[mm].DynamometerTopViewThiswindowshowsadrawingdefiningthecoordinatesystem,andsensorlayoutfortheselecteddynamometer.Usethisasaguidewhenenteringsensordistances,configuringyoursystemandinterpretingdata.OutputWindowTheoutputwindowshowschannelallocationforacquiredandcalculatedchannels.Thisshouldbeusedasaguidewhenconfiguringgraphs.6.2.1.5ConfigurationsusingType5011/5015amplifiersSelectingType5011/5015intheamplifierselection(seesection6.2.1.3)willenabletheChargeAmplifierType5011/5015tab.6.2.1.5.1ChargeAmplifierType5011/5015Thefollowingparametersshouldbesetwhenusing5011/5015chargeamplifiersinDynoWare:CommunicationsSelectionTheusercanselecttheremotecontrolmode,eitherviaRS-232C(inwhichcaseonlychannel1canberemotelycontrolled)orviaIEEE-488(inwhichcaseallchannelscanberemotelycontrolled).IfRS-232Cischosen,aRS-232CSetuptabwillappeartoallowcustomconfigurationofthecommunicationparameters.IfIEEE-488ischosen,anIEEE-488(GPIB)Setuptabwillappeartoallowselectionofthecommunicationlibrary.ChannelChannelnumber.Channelsrangefrom1to8.LabelEnteranylabelforeachchannel.Thislabelwillappearongraphsandreports.MeasuringRangeEntertheMeasuringRange[M.U.]ofeachchannel(M.U.=MechanicalUnit).UnitEnterthedisplayunitsofeachchannel.ScaleTheScalesettingfortheamplifierisautomaticallydeterminedfromtheMeasuringRangeandthefullscaleoutputcapabilityoftheamplifier.Scale[M.U./V]=MeasuringRange[M.U.]/10,0[V]Output;(M.U.=MechanicalUnit)SensitivityEnterthesensitivityofasensor(seecalibrationsheet).FilterSelectthedesiredlow-passfilter(internalsignalfilterinthesignalconditioner)tobeused.TimeConstantSelectthedesiredhigh-passfilterTimeConstant(internalsignalfilterinthesignalconditioner)tobeused.IEEEAddressEntertheIEEE-488addressoftheselectedType5011/5015.Theselectedchanneladdressmustmatchtheaddressconfiguredinthe5011/5015.PleaserefertoType5011/5015usermanualforinformationonconfiguringtheDynoWareType2825A…Page462825A_002-195e-02.11IEEE-488address.Eachdevicemusthaveauniqueaddress.ThisappliesonlyifIEEEcommunicationmodeisselected.MeasureTransmitthecommandtoplacetheamplifierintothemeasure(operate)mode.ResetTransmitthecommandtoplacetheamplifierintoresetmode.SendParameterTransmitthecommandtosettheappropriateperchannelconfigurationforSensitivity,Range,Filter,andTimeconstantsettings.Reset/OperateEnabletheautomaticcontrol(viaRS-232CorIEEE-488interface)oftheOperate/Resetcommandsduringatypicalacquisitioncycle.Amplifierwillbeautomaticallysettooperateatthestartofacycle,andwillreturntoresetaftertheacquisitionhascompletedforanygivencycle.Insomecases,thisautomaticcontrolofReset/Operateisnotdesiredandtheselectionboxshouldremainunchecked.6.2.1.5.2RS-232CSetup(Seesection4.8or6.2.1.4.2)–ThistabwillonlyappearifRS-232Cinterfaceisselected.6.2.1.6SetupforChargeAmplifierType5018IfType5018ischosen(seesection6.2.1.3),theparametersforchargeamplifierType5018areapplied.6.2.1.6.1ChargeAmplifierType5018ThefollowingparametersmustbesetifchargeamplifierType5018isbeingused:ChannelDisplaysthespecificchannelnumberrangingfrom1to8.LabelEnteranylabelforeachchannel.Thislabelwillappearongraphsandreports.MeasuringRangeEntertheMeasuringRange(maximummeasurableamount)[M.U.]foreachchannel(M.U.=mechanicalunit).UnitEnterthemechanicaldisplayunitsofeachchannel.ScaleTheScalesettingfortheamplifierisautomaticallydeterminedfromtheMeasuringRangeandthefullscaleoutputcapabilityoftheamplifier:Scale[M.U./V]=MeasuringRange[M.U.]/10,0[V]Output.SensitivityEnterthesensitivityofthesensor(seecalibrationsheet)Reference2825A_002-195e-02.11Page47FilterSelecttherequiredlow-passfilter(internalfilterinthechargeamplifier).TimeconstantSelecttherequiredTimeConstantofthehigh-passfilter(internalhardwarefilterinthechargeamplifier).COMxEntertheCOMportoftherequiredType5018.Eachdevicemusthaveitsownaddress.Ontheselectedconnectortheserial(RS-232CorUSB)cablemustbeconnectedtothechargeamplifier.MeasureTransmitthecommandtoswitchtheamplifierintothemeasure(operate)mode.ResetTransmitthecommandtoswitchtheamplifierintotheResetmode.SendparametersTransmitthesettingsforSensitivity,Range,FilterandTimeConstantforeachchanneltothechargeamplifier.Reset/OperateEnableautomaticcontrol(viaRS-232CorUSBinterface)oftheOperate/Resetcommandsduringameasuringcycle.Theamplifierwillbeautomaticallysettooperateatthestartofacycle,andtoresetafteranygivencyclehasbeenacquired.Thisautomaticcontroloptionmustbedisabledinthoseparticularcasesinwhichitisnotrequired.6.2.1.6.2RS-232CSetupSeesection4.8or6.2.1.4.26.2.1.6.3USBSetupThechargeamplifierType5018canalsobecontrolledviaUSBinsteadofRS-232C.Thefollowingsettingsmustbemade:ConnecttheType5018tothePCwiththeincludedUSBcable.Installthedrivers(fromtheCDincludedwiththeType5018)ifthishasnotalreadybeendone.ChooseCOMxport.ThechosenCOMportmustbethesameasthattowhichthechargeamplifierisconnected.PleasetakealookattheWindowsdevicemanager(seechapter6.2.1.4.2).6.2.1.7ConfigurationsusingOtherAmplifiersSelectingOthersintheamplifierselection(seesection6.2.1.3)willenabletheOthertab.DynoWareType2825A…Page482825A_002-195e-02.116.2.1.7.1OthersTheotheradaptertaballowsforgenericamplifierconfiguration.Inthissetupnospecificequipmentiscont-rolled.ThedataprovidedallowsDynoWaretoconvertdatafrommeasuredvoltagestorealmechanicalunits.Theinformationconfiguredinthistabis:ChannelChannelnumberusedforconfigureddevicesandcon-nections.LabelEnteranylabelforeachchannel.Labelswillappearongraphsandreports.MeasuringRangeEnterthemeasuringRangeofeachchannel(ifnotactivated,usedoubleclickorF4).Youcaneitherenteranoverallmeasuringrange,oranindividualrangeandsensitivity.MeasuringRange[M.U.]=SensorRange[pC]dividedbySensitivity[pC/M.U.](M.U.=MechanicalUnit).UnitEntertheunitofeachchannel.TheconfiguredunitswillappearongraphsandreportsFSEnterthefullscale(FS)ofeachchannel.Range1Entertherangeoftheadapterforeachchannel(activatewithdoubleclickorF4).SensitivityEnterthesensitivityofasensor(activatewithdoubleclickorF4).6.2.1.8ConfigurationsUsingRotatingCuttingDynamometerType9123/9124withSignalConditionerType5223SelectingRCDType9123/9124withSignalConditionerType5223intheamplifierselection(seesection6.2.1.3)willenabletheRCD5223tab,theRS-232CSetuptab,andtheRCDCalculationstab.6.2.1.8.1RCD5223Therotatingcuttingdynamometerrequirestheconfigu-rationofthefollowingparameters:ChannelChannelnumber.Channelsrangefrom1to6.LabelAssignlabelsforeachchannel.Theselabelsappearingraphsandreports.MeasuringRangeThemeasuringrangeisautomaticallyassignedbasedontheScaleandSensitivitysettings.MeasuringRange[M.U.]=FullScaleOutput[mV]dividedbySensitivity[mV/M.U.];(M.U.=MechanicalUnit).UnitAssignunitstoeachchannel.Theselabelsappearingraphsandreports.FullScaleOutput(FSO)Assignthefullscalesettingfortheamplifierin[mV].SensitivityEnterthesensitivityofasensorin[mV/M.U].Twosensitivities(coarse/finerange)forforcesFx,FyandFzarespecifiedonthecalibrationsheet.EvenfoursensitivitiesarespecifiedforthetorqueMz.Reference2825A_002-195e-02.11Page49RangeSelectionSelectthedesiredmeasurementrange.RangeIisacoarserange,RangeIIisafinerange.ZoomChannelSelectthechanneltoappearasthezoomoutputchannel.YoucanselectFx,FzorMz.Theoutputsignalofchannel5(zoomedchannel→seemanualofrotatingDynamometer)ofthesignalconditioneramplifiesthesignalbyfactor10.Thesamesensitivityhastobeenteredforbothoriginalchannelandzoomedchanneltoamplifybyfactor10.MeasureTransmitthecommandtoplacetheamplifierintothemeasure(operate)mode.ResetTransmitthecommandtoplacetheamplifierintoresetmode.SendParametersTransmitthecommandtosettheappropriateperchannelconfigurationforSensitivityandRangesettings,andthezoomchannelselection.Reset/OperateEnabletheautomaticcontrol(viaRS-232Cinterface)oftheOperate/Resetcommandsduringatypicalacquisitioncycle.Amplifierwillbeautomaticallysettooperateatthestartofacycle,andwillreturntoresetaftertheacquisitionhascompletedforanygivencycle.Insomecases,thisautomaticcontrolofReset/Operateisnotdesiredandtheselectionboxshouldremainunchecked.6.2.1.8.2RS-232CSetup(seesection4.8or6.2.1.4.2)6.2.1.8.3RCDCalculationsWithType5223...additionalsoftwarecalculationscanbeperformed.Thesecalculationscanprovideradialandtangentialforcesoractiveforceinavarietyofapplications.IfaRCDcalculationisenabled,theusercannolongeren-able/disablechannelsintheChannelsconfiguration(seesection6.2.2.2).6.2.1.8.3.1OffRCDCalculationsaredisabledDynoWareType2825A…Page502825A_002-195e-02.116.2.1.8.3.2Type1Thetype1RCDCalculationcomputestheactiveforceFa.ThetooldiameterDdoesnothavetobeenteredforthiscalculation.6.2.1.8.3.3Type2Thetype2RCDCalculationcomputestheFr(RadialForce)andFt(tangentialforce)cuttingforceparameters.TheusermustconfiguretooldiameterD.ToolDiameterEnterthetooldiameterfortheappropriatetoolundertest.Alldistancesareenteredinmillimeters"mm".ToolViewThiswindowshowsadrawingdefiningthecoordinatesystem,andtoolmeasurementlayoutfortheselecteddynamometer.OutputWindowTheoutputwindowshowschannelallocationforacquiredandcalculatedchannels.Thisshouldbeusedasaguidewhenconfiguringgraphs.Reference2825A_002-195e-02.11Page516.2.1.9ConfigurationsUsingRotatingCuttingDynamometerType9125withSignalConditionerType5237SelectingRCDType9125withSignalConditionerType5237intheamplifierselection(seesection6.2.1.3)willenableRCDType5237tab,andtheRS-232CSetuptab.6.2.1.9.1RCDType5237ToconfigureType5237highspeedrotatingcuttingdynamometer,configurethefollowing:ChannelChannelnumber.Channelsrangefrom1to2.LabelAssignlabelsforeachchannel.Theselabelsappearingraphsandreports.MeasuringRangeThemeasuringrangeisautomaticallyassignedbasedontheScaleandSensitivitysettings.MeasuringRange[M.U.]=FullScaleOutput[mV]dividedbySensitivity[mV/M.U.];(M.U.=MechanicalUnit)UnitAssignunitstoeachchannel.Theselabelsappearingraphsandreports.SensitivitiesRangeI,RangeIIandRangeIII–enterthesensitivityofasensorin[mV/M.U.]foreachofthecalibratedranges(seecalibrationsheet).RangeSelectionSelectthedesiredmeasurementrangefromthepull-downchoicebox.RangeIisacoarserange,rangeIIIisafinerange.MeasureTransmitthecommandtoplacetheamplifierintothemeasure(operate)mode.ResetTransmitthecommandtoplacetheamplifierintoresetmode.SendParametersTransmitthecommandtosettheappropriateperchannelconfigurationfortheRangesettings.Operate/ResetEnabletheautomaticcontrol(viaRS-232Cinterface)oftheOperate/Resetcommandsduringatypicalacquisitioncycle.Amplifierwillbeautomaticallysettooperateatthestartofacycle,andwillreturntoresetaftertheacquisitionhascompletedforanygivencycle.Insomecases,thisautomaticcontrolofReset/Operateisnotdesiredandtheselectionboxshouldremainunchecked.6.2.1.9.2RS-232CSetup(seesection4.8or6.2.1.4.2)DynoWareType2825A…Page522825A_002-195e-02.116.2.1.10ConfigurationsusingMultichannelAmplifierType5070SelectingType5070intheamplifierselection(seesection6.2.1.3)willenabletheMultichannelAmplifierType5070tab,theRS-232CSetuptab,andtheForce&MomentCalculationtab.6.2.1.10.1MultichannelAmplifierType5070TheMultichannelconfigurationtaballowsforcustomi-zationofType5070MultichannelAmplifier.Thereareseveralconfigurableparametersassociatedwiththisamplifier:5070versionSelectsType5070version,4-channel,8-channelor8-channelsummation.Theversionaffectsthebehavioroftheremainingoptions.ChannelChannelnumberdisplaysthespecificchannelnumberrangingfrom1to8(channels1to4for4-channeltype).LabelEnteranylabelforeachchannel.Thislabelwillappearongraphsandreports.SensitivityEnterthesensitivityofasensor(seecalibrationsheet).Unit(Sensitivity)Enterthesensitivityunitsofasensor(seecalibrationsheet).MeasuringRangeEntertheMeasuringRange(Maximummeasurableamount)ofeachchannel.Unit(MeasuringRange)EntertheMeasuringRangeUnit/DisplayUnitofeachchannel.FilterSelectthedesiredlow-passfilter(internalfilterinthesignalconditioner)tobeused.TimeConstantSelectthedesiredTimeConstant(internalhigh-passfilterinthesignalconditioner)tobeused.MeasureTransmitthecommandtoswitchtheamplifierintothemeasuremode(operatemode).ResetTransmitthecommandtoswitchtheamplifierintoresetmode.SendParametersTransmitthecommandtosettheappropriateperchannelconfigurationforSensitivity,Range,Filter,andTimeconstantsettings.MeasureModeSettoOnStartAcquisitionforautomaticcontrol(viaRS-232Cinterface)ofthemeasuremode(Operate/Reset)duringatypicalacquisitioncycle.Amplifierwillbeautoma-ticallysettooperateatthestartofacycle,andwillreturntoresetaftertheacquisitionhascompletedforanygivencycle.Insomecases,thisautomaticcontrolofReset/OperateisnotdesiredandtheselectionboxshouldbesettoManual(5070).SensorDistances(AvailableforType50708ChannelSummingonly)Enterthedynamometerdimensions'a'and'b'inmm.Seesection6.2.1.10.3formoreinformation.Reference2825A_002-195e-02.11Page53CorrectionFactors(AvailableforType50708ChannelSummingonly)EnterthedynamometermomentcorrectionfactorskMx,kMyandkMzfromthedynamometercalibrationsheet.Thesecorrectionfactorsarespecifiedonlyifthedynamometerwascalibratedwithacustomcalibration.6.2.1.10.2RS-232CSetupTheRS-232CconfigurationmustbeproperlyconfiguredusingtheRS-232CSetupTabforType5070tofunctionproperly.SerialPortSelectstheCOMportusedtocontrolthesignalconditioner.ThisistheportonthePCtowhichtheserialcableisconnected(seesection4.8).BaudRateSelectsthedatatransmissionrateusedtocommunicatewiththesignalconditioner.Thissettingmustbeidenticaltothesettinginthesignalconditioner.Refertothesignalconditionermanualtodeterminethepropersetting.DataBitsFixedat8databitsforType5070amplifier.StopBitFixedat1stopbitforType5070amplifier.ParityFixedatOFFdatabitsforType5070amplifier.HandshakingFixedatNoneforType5070amplifier.6.2.1.10.3Force&MomentCalculationWiththeType5070versionsetto8-channelandtheappropriateequipment,additionalsoftwarecalculationscanbeperformed.Thesecalculationscanprovideresultantforcesandtorquesforvarioustypesofdynamometers,inavarietyofapplications.Ifamultichannelcalculationisenabled,theusercannolongerenable/disablechannelsintheconfiguration(Section6.2.2.2).SelecttheMulticomponentModecalculationtypefromthelistpresentedcorrespondingtoyourspecifichardwaredynamometer.The8-channelversionofthechargeamplifierType5070withhardwaresummationcalculatestheresultantforcesandtorquesinrealtime.However,onlythetype4dynamometerissupportedinthiscase(seesection6.2.1.10.3.6).6.2.1.10.3.1ModeOffForceandMomentcalculationdisabled.DynoWareType2825A…Page542825A_002-195e-02.116.2.1.10.3.2Type1OptionnotallowedwithType5070amplifier.6.2.1.10.3.3Type1aThetype1adynamometermeasures4shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMzarecalculated.Theusermustconfigurethedistancesa1,a2,b1,andb2.ThisisonlyavailableforType50708-channel.6.2.1.10.3.4Type2OptionnotallowedwithType5070amplifier.6.2.1.10.3.5Type3Thetype3dynamometermeasures4shearcomponentsand2verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,Mzarecalculated.Theusermustconfigurethedistancesaandb.Thetype3dynamometerisforthedynamometer'MiniDyn'Type9256...only.Reference2825A_002-195e-02.11Page556.2.1.10.3.6Type4Thetype4dynamometermeasures4shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,My,Mzarecalculated.Theusermustconfi-gurethedistancesaandb.Thisoptionisavailablefor8-channeland8-channelsumming.6.2.1.10.3.7Type5Thetype5dynamometermeasures5shearcomponentsand3verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,My,Mzarecalculated.Theusermustconfigurethedistancesa,bandc.Thisisonlyavailablefor8-channel.SensorDistancesEnterthedistancesbetweensensorsfromthedrawingorthedatasheetofamplifierType5070givenfortheappropriatedynamometertype.Alldistancesareenteredinmillimeters[mm].DynamometerViewThiswindowshowsadrawingdefiningthecoordinatesystem,andsensorlayoutfortheselecteddynamometer.Usethisasaguidewhenenteringsensordistances,configuringyoursystem,andinterpretingdata.OutputWindowTheoutputwindowshowschannelallocationforacquiredandcalculatedchannels.Thisshouldbeusedasaguidewhenconfiguringgraphs.DynoWareType2825A…Page562825A_002-195e-02.116.2.1.11SetupforMultichannelChargeAmplifierType5080IftheType5080ischosen(seesection6.2.1.3),theparametersforthismultichannelamplifierareapplied,withothertabsfortheserialinterfaceandmulticomponentmeasurement.6.2.1.11.1MultichannelAmplifierType5080Themultichannelsetuptaballowstheuser-definedsettingsforthechargeamplifierType5080.Thefollowingparameterscanbeset:5080VersionChoosestheversionormodeofthechangeamplifierType5080,1-channel,2-channel,…8-channeland8-channelsumming(withhardwaresummation).ChannelChannelnumberdisplaysthespecificchannelnumberfrom1to8.LabelEnteranylabelforeachchannel.ThislabelwillappearongraphsandreportsModeThesoftwareidentifiesdifferentmodules(Type5067)usedintheamplifierType5080.ThemodecanonlybechangedifaDual-Modemodule(Charge,Voltage,Piezotron)isused.SensitivityEnterthesensitivityofthesensor(seecalibrationsheet)Unit(Sensitivity)Entertheunitforthesensorsensitivity(seecalibrationsheet).MeasuringRangeEntertheMeasuringRange(maximummeasurableamount)[M.U.]ofeachchannel(M.U.=mechanicalunit).Unit(MeasuringRange)EntertheunitfortheMeasuringRange.CurrentIfaDual-ModemoduleissettoPiezotrontheoutputcurrenthastobedefined.Thecurrentrangesfrom1…15mA.FilterChoosetherequiredlow-passfilter(internalfilterinthechargeamplifier).TimeConstantChoosetherequiredTimeConstantofthehigh-passfilter(internalhardwarefilterinthechargeamplifier).MeasureTransmitthecommandtoswitchtheamplifierintotheMeasure(Operate)mode.ResetTransmitthecommandtoresettheamplifierintotheMeasuremode.SendParametersTransmitthesettingsforSensitivity,Range,FilterandTimeConstantforeachchanneltothechargeamplifier.MeasureModeEnableautomaticcontrol(viaRS-232Cinterface)oftheMeasure/Resetcommandsduringameasuringcycle.TheamplifierisautomaticallysettoMeasureatthestartofacycle,andreturnedtoresetafteranygivencyclehasbeenacquired.Thisautomaticcontroloptionmustbedisabledinthosecasesinwhichitisnotrequired.Reference2825A_002-195e-02.11Page57SensorDistances(AvailableforType50808-channelSummingonly)Enterthedynamometerdimensions'a'and'b'in[mm]intheappropriatefields.CorrectionFactors(AvailableforType50808-channelSummingonly)Enterthedynamometertorquecorrectionfactors'kMx','kMy'and'kMz'fromthedynamometercalibrationsheet.Thesecorrectionfactorsarespecifiedonlyifthedynamometerwascalibratedwithaspecialcalibration.6.2.1.11.2RS-232CSetupTheRS-232CinterfacemustbecarefullyconfiguredusingtheRS-232CSetuptabforType5080tooperateproperly.SerialPortSelectstheCOMport.Theserialcabletothechargeamplifiermustbeconnectedtothechosenconnector(seesection4.8).BaudRateSetthedatatransmissionrateusedtocommunicatewiththechargeamplifier.Thissettingmustbeidenticaltothatofthechargeamplifier.Refertothechargeamplifiermanualtodeterminethecorrectsetting.DataBitsFixedat8databitsforType5080amplifier.StopBitFixedat1databitforType5080amplifier.ParityFixedatNoneforType5080amplifier.HandshakingFixedatNoneforType5080amplifier.6.2.1.11.3USBSetupThechargeamplifierType5080canalsobecontrolledviaUSBinsteadofRS-232C,butonlyiftheDAQ-SystemType5697isnotbeingused.Thefollowingsettingsmustbemade:ConnecttheType5080withtheincludedUSBcabletothePC.Installthedrivers(fromtheCDincludedwiththeType5080)ifthishasnotalreadybeendone.Chooseserial(COM)port.ThismustbethesameastheCOMporttowhichthechargeamplifierisconnected.PleasetakealookattheWindowsdevicemanager.DynoWareType2825A…Page582825A_002-195e-02.116.2.1.11.4Force&TorqueCalculationWithatleastthe6-channelversionofthechargeamplifierType5080andsuitabledynamometers,resultantforcesandtorquescanbecalculatedfordifferenttypesofdynamometerinavarietyofapplications.Ifmultichannelcalculationisenabled,theusercannolongerenable/disableindividualchannelsintheconfiguration(section6.2.2.2).ChoosetherequiredMulticomponentModefromdisplayedlistcorrespondingtoyourdynamometerandtheapplication.The8-channelversionofthechargeamplifierType5080withhardwaresummationcalculatestheresultantforcesandtorquesinrealtime.However,onlythetype4dynamometerissupportedinthiscase(seesection6.2.1.11.4.6).6.2.1.11.4.1OffModeMulticomponentmeasurementsdisabled.6.2.1.11.4.2Type1ThistypeisnotsupportedbytheType5080chargeamplifier.6.2.1.11.4.3Type1aThetype1adynamometermeasures4shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMzarecalculated.Theusermustconfigurethedistancesa1,a2,b1andb2.Thisisonlyavailableinthe8-channelmode.6.2.1.11.4.4Type2ThistypeisnotsupportedbytheType5080chargeamplifier.Reference2825A_002-195e-02.11Page596.2.1.11.4.5Type3Thetype3dynamometermeasures4shearcomponentsand2verticalcomponents.FromtherawcomponentsFx,Fy,Fz,MxandMzarecalculated.Theusermustconfiguretheaandbdistances.Thistypeisonlyusedwhenthe'MiniDyn'Type9256…dynamometerisbeingemployed.6.2.1.11.4.6Type4Thetype4dynamometermeasures4shearcomponentsand4verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,My,Mzarecalculated.Theusermustconfigurethedistancesaandb.Thisoptionisavailableinthe8-channeland8-channelsummingmode.6.2.1.11.4.7Type5Thetype5dynamometermeasures5shearcomponentsand3verticalcomponents.FromtherawcomponentsFx,Fy,FzandMx,My,Mzarecalculated.Theusermustconfigurethedistancesa,bandc.Thisoptionisonlyavailableinthe8-channelmode.DynoWareType2825A…Page602825A_002-195e-02.11SensorDistancesEnterthedistancesbetweensensorsfromthedrawingsortheamplifierType5080datasheetforthetypeofdynamometerbeingused.Alldistancesareinmillimeters[mm].DynamometerViewThiswindowshowsadiagramdefiningthecoordinatesystemandsensorlayoutforthechosendynamometer.Usethisasaguidewhenenteringsensordistances,configuringyoursystemandinterpretingdata.OutputWindowTheoutputwindowshowschannelallocationforacquiredandcalculatedchannels.Thisshouldbeusedasaguidewhenconfiguringgraphs.6.2.2Edit…Shortcut:Alt+ESelectingAcquisitionEditallowsconfigurationofthedataacquisitionprocessforDynoWare.TheParameterstabprovidesconfigurationofthebasicsamplingandstoragecriteria.TheChannelstabprovidesselectionofthetriggermethodandthechannelsavailable.TheDataManipulationtaballowsforusercustomizeddatacalculationstobeperformedonacquireddata.Fig.20:EditacquisitionparametersReference2825A_002-195e-02.11Page616.2.2.1ParameterTheParameterstaballowsforconfigurationofthefollowing:MeasuringTimeDefinitionoftheactualdurationofacquisitionmeasuredinseconds.SampleRateTheSampleratedefinesthenumberofmeasurementspersecondandperchannel.Thehigherthesamplerate,thebetteristheresolutionofthemeasuringsignal.Becauseofthehugeamountofdataahighsamplerateisautomaticallyequivalenttoslowdataprocessingandgraphicsrendering.Fordetailedanalysis,however,2000Hzorhighermightbenecessary.Highsamplingratesandlongacquisitiondurationcancreatelargefiles.Ensurethatthereisenoughdiskspaceavailablewhenusingcontinuousmonitoring.CyclesThisdefinesthenumberofmeasuringcycles(machinecycles)tobeacquired.ContinuousIfcheckedthenumberofcyclesisunknown.Theacqui-sitionhastobestoppedmanually.TriggerDelayTimeThedelaytimebetweenthetriggersignalandmeasure-mentstart.Thiscaneffecttheresultsofdatacollectionifusedwiththepretriggerfunctionality.SaveDynoWarefileEnablesavingtheacquisitiondataintoafile.DisplaydataEnabledisplayingacquireddataonthescreen.ExportaftereachcycleIfenabled,aseparatetextfilecanbeautomaticallyexportedaftereachdatacycle.TheConfigurebuttonallowsforconfigurationofthecontentsoftheexportedfile.ShowrealtimeupdatesIfShowrealtimeupdatesduringacquisitionisenabledthegraphwillbeperiodicallyupdatedduringtheacquisitionprocess.Insomecases(suchasveryhighacquisitionrateandhighchannelcounts)enablingrealtimeupdatesmayresultinerrorsduringthedataacquisitionprocessandshouldbedisabled.InformationDisplaysinformationaboutthenumberofChannelsusedformeasurement,thenumberofSamples/Channel,andtheapproximatememorystoragesizeneededforoneDynoWareType2825A…Page622825A_002-195e-02.11cycle.Thisdependsonthenumberofchannels,thesamplingtime,andthesamplingrate.FileThenameofthefile.Thefileextensionis'*.dwd'.Browse…Browseenablesvisualselectionofadirectory(folder)andafilename,usetheBrowsefunctiontofindandoverwriteanexistingfileortobrowseforafolder.DirectoryDisplaystheselecteddirectoryorfolderonadiskwherethefilewillbestored.SaveconfigurationEnablethechecktosavetheconfigurationwhenstartingmeasurement.DynoWareusesthesamefilenameasforthedatafile,butwiththeextension'*.cfg'forconfigurationfiles.SeeSection6.1.3.2ConfigurationSave…formoreinformationaboutconfigurations.6.2.2.2ChannelsTheChannelstabisconfiguredwiththefollowingoptionsinthetableandtriggersections:ChannelDisplaysthenumberofthechannel.On(Enable)Activates/DeactivatesachannelifMulticomponentMea-surementmodeisnotactivated.TriggerActivateachannelasa'triggerchannel'incaseofanalogtriggermode.LabelEnteranylabelforthechannel(e.g.drillingmoment).Trigger:OnakeyMeasurementisstartedbypressingtheEnterkey.Trigger:Digital(Types5070,5080,5238–NPN)MeasurementisstartedbyapulseatthedigitalinputofthechargeamplifierType5070orType5080orsignalconditionerType5238(e.g.withinductiveproximityswitchType2233B).Trigger:DAQMeasurementisstartedbyanexternaltriggersignalintothedataacquisitioncard(e.g.startmachine).ThissignalcanbefedintoeithertherelevantinputforcableTypes1500A7or1500B15ortheconnectingboxoftheDAQ-SystemType5697A.Trigger:AnalogMeasurementisstartedifthedefinedchannelhasreachedacertainlevel.Rising/FallingStartoftheTriggeratrisingorfallingedge.%/AbsoluteTheanalogtriggerthresholdisdefinedasapercentageoranabsolutevalue.ThresholdSpecifiesinM.U.(mechanicalunits)orvoltstheanalogtriggerthreshold.Reference2825A_002-195e-02.11Page63PretriggerWhenenabled,theresultanttrialwillcontainthespecifiedpretriggerpercentageofdatapriortothetriggercondition.Ifthetrialis10secondslongand50%pretriggerisspecified,theresultingtrialwillcontain5secondsofdatapriortothetriggerand5secondsofdataafterthetrigger.Thisisachievedbyfillingapretriggerbuffer,thencontinuouslywaitingforthetriggersignal.Pretriggercanrangefrom1…99%.Fig.21:Editacquisitionchannels&trigger6.2.2.3DataManipulationFig.22:Editacquisition,datamanipulationonlineDynoWareType2825A…Page642825A_002-195e-02.11Dataforanyspecifiedchannelcanbemodifiedwithstandardmathematicalfunctionsimmediatelyafterthedataisacquired.Thesourcechannelsandoperationtobeperformedmustbespecifiedaswellasthedestinationofthecalculation.Thedestinationchanneldataispermanentlydestroyed.Usethedatamanipulationfunctionswithextremecaution.On(Enable)Activatethefunctionforthedatamanipulation.1.BaseFirstchannelforthedatamanipulation.2.BaseSecondchannelforthedatamanipulation.Hereyoumayalsoenterconstantvalues.Note:ConfirmnumericalentrieswithRETURN.OperationThemathematicaloperationtobeperformed.Thefollowingfunctionsareavailable:Addition,Subtraction,Multiplication,Division,loga,lnb,exp(e)c,exp(10)d,sqre,sqrtf.ResultChanneltoplacetheresult.AddAddanewfunction.RemoveRemovetheselectedfunction.6.2.3Start...Shortcut:Alt+STobeginthedataacquisitionprocess,selecttheAcquisitionStartmenuchoice.Ifthespecifiedstoragefilealreadyexists(asspecifiedinsection6.2.2.1AcquisitionParameter)apromptwillappeartooverwritetheexistingfile.Ifyouchoosetooverwritethefile,allexistingdatainthefilewillbelost.abase10logarithmbnaturallogarithmcnaturalexponentialdbase10exponentialesquarefsquarerootReference2825A_002-195e-02.11Page65Fig.23:OverwritefilepromptFirst,ifenabled,theDocumentationdialog(seeSection6.3.4.1)willappear.Herenotesaboutthegivencyclecanbeaddedorchangedtodocumentthetrialcycle.Next,ifShowHardwaredialogbetweenAcquisitionCyclesisenabled(seeSection6.2.1.2ShowHardwareDialogbetweenAcquisitionCycles),theHardwarecon-figurationdialogwillappearallowingchangestotheamplifierconfiguration.Finally,themaindataacquisitiondialogboxwillappearshowingthecurrentcyclenumber.Ifanalogordigitaltriggeringisrequired,thesystemwillgointothewaitfortriggerstate.IfKeytriggeringisenabledpressingtheGobuttonortheEnterkeywillstartacquisition.Onceatriggerhasoccurred,orGohasbeenselected,theprogressbarwillupdatetoindicateacquisitionstatus.Toabortacquisition(orstopacontinuouscycleacqui-sition),presstheStopbutton.Acquireddataissaved.Fig.24:BeginacquisitionpromptThedataacquisitionprocessmaytakeseveralsecondstoabortbeforethenextacquisitionintervalcanbegin.DynoWareType2825A…Page662825A_002-195e-02.116.3View...TheViewmenuprovidesforcompletecontrolofthegraphicaloutputofDynoWare.Graphtypesanddatacon-tentcanbeselectedforindividualviewsandforconfigura-tionofadefaultviewset.6.3.1New…Withaspecificwindowopen,selectingNew…willcreateanewduplicatewindowwiththeidenticalconfigurationasthecurrentactivewindow.Thisnewviewcannowbeconfiguredindividually.6.3.2Edit…Shortcut:Alt+VTheViewEditconfigurationprovidesforcontrolofthecurrentwindowsgraphtypeandcontaineditems.Theusercanalsocustomizethecolorsofaspecificgraphitemfromthisdialogbox,andsetviewdependence(linktootheropenviewsofthisfile).Fig.25:ViewEditSelectedCyclesandChannelsarecheckmarked.Clickonanitemtohighlightorselectit.Clickonahighlighteditemtounselectit.Therearethreetypesofgraphics:y(t),y(x),andnumerical.Inordertoselectorchangethex-axisinay(x)graph,clickonthey-xicon.ThefollowingdescribesadditionalitemsintheViewEditdialog:FileDisplaysthenameofthefile.On(Enable)Activateachannel.Reference2825A_002-195e-02.11Page67CycleSelectsthecyclestobedisplayedintheview.Iftwoandmorecyclesareselected,theywillbesuperimposed(seesection6.3.2.1)ChannelSelectthechannelstobedisplayed.ColorShowsthecolorselectionforeachchannel.Colorcanbechanged.vs.Y2Selectingvs.Y2allowsgraphingvs.twoverticalaxisscales.Onescalingwillappearontheleftofthegraph,thesecondscalewillappearontherightofthegraph.Thelegendwillindicatethecorrespondingaxisthatappliestoeachline.vs.Y2appliestotimebasedgraphsy(t)only.Selectall/UnselectallSelects/Unselectsallcyclesorchannelstoview.ViewdependenceLinkstwoormorewindows.Changinginonewindowfromonecycletothenextwillupdatetheotherwindowsaccordingly.6.3.2.1SuperimpositionofviewsItispossibletosuperimposesignalsiftwoormorecyclesareacquiredinonefile.AllcyclesthathavetobesuperimposedhavetobeactivatedintheViewEditdialog.DynoWareType2825A…Page682825A_002-195e-02.116.3.3Setup…Fig.26:ViewSetupWithViewSetupyoucanconfigurethewindowsanddefaultgraphsthatwillappearwhenafileisopenedorwhendataisacquired.AusercanconfigureseveraldefaultwindowsbyrepeatedlypressingtheAddbuttonandfollowingtheonscreenwizardforcreatinganewviewwindow.Toremoveanexistingview,highlighttheviewintheDataViewswindowandselecttheRemovebutton.Tofindmoreinformationaboutaview,highlightitintheDataViewswindowandpresstheDetailsbutton.Ausercanchangecolorsandchooseasecondverticalaxis(vs.Y2)inthisdialog.SettingschoseninthisdialogwillbedisplayedonscreenwhentheoptionShowrealtimeupdatesduringacquisitionisenabled(seesection6.2.2.1).6.3.4DocumentationShortcut:Alt+DEachindividualcyclecanhaveadditionaldocumentationassociatedwithit.Therearetwotabsinthedocumentationdialog,CommentsandFile,Date,Time.6.3.4.1CommentsTheComments(Fig.27:Documentation)taballowsuserenteredtextdatatobeassociatedwitheachcycle.Thechangesareupdatedimmediatelyinthefile.Reference2825A_002-195e-02.11Page69Fig.27:DocumentationDocumenttitleAllowsforcustomizationofthegraphtitlesRemarksGeneraltextcommentscanbeenteredintheremarkssectionMaterialInCuttingForceDocumentationmode,theusercansupplyamaterialtypecommentToolInCuttingForceDocumentationmode,theusercanenterspecificinformationaboutthecuttingtoolundertest.CuttingForceParametersvc=cuttingvelocity[m/min]f=feed[mm/rev]ap=depthofcut[mm]n=speed[rpm]vf=feedvelocity[mm/min]ae=cutterengagement[mm]DocumentationModeSpecifytodocumentspecificcuttingforceparameters,ortodocumentthefileusinggeneralcomments.ShowDocumentationBetweenacquisitioncyclesenabletheautomaticdisplayofthedocumentationdialogboximmediatelypriortoacquiringacycle.6.3.4.2File,Date,TimeTheFile,Date,Timetabdocumentsthetemporalandstoragedataassociatedwiththeoriginalacquisition.FolderThedirectorywherethefilewasinitiallycreatedFileTheinitialnameofthefileDateTheoriginaldateoftheacquisitionTimeTheoriginaltimeoftheacquisitionDynoWareType2825A…Page702825A_002-195e-02.116.3.5EditLabelsTheusercaneditthechannellabelsorunitlabelsofspecificchannelsatanytimeusingtheViewEditLabelsselection.Thechannellabelorunitenteredforanyonespecificchannelwillbeappliedtoallofthestoredcycleswithinthefile.Thechangesareupdatedimmediatelyinthefile.Fig.28:EditLabels6.3.6ResetFonttoDefaultThefont,color,sizeandstylecanbechangedbydouble-clickingthewordtobealteredinthebox.Toresetthechosensettingstothedefaults,selectResetFonttoDefaultfromtheViewmenu.6.3.7ResetColortoDefaultThechosencolorsofthesignalscanberesettothedefaultsettings.ChooseResetColortoDefaultfromtheViewmenu.6.3.8ZoomTheZoomfunctionprovidesforchangingthex-axisandy-axisscalingparametersforanactivegraph.Theusercanmanuallyzoombyenteringtheaxisminimumandmaximumvaluesorgraphicallyzoomusingtherightmousebutton.6.3.8.1ManualZoomBydefaultallgraphsarescaledtobestfittheminimumandmaximumvaluesofthecontainedgraphs.SelectingViewZoompresentsadialogboxwhichcanbeusedtosetthex-axisminimumandmaximumvaluesandthey-axisminimumandmaximumvalues.Thedialogboxwillremainactive(buttonApply)sothattheusercanswitchtootherReference2825A_002-195e-02.11Page71openwindowsandchangethezoomsettings.NewsettingswillbeactivatedwhentheOKbuttonisselected.TheZoomOffbuttonwillrestorethegraphtotheoriginalautoscaledvalues.AzoomedgraphwillhavethewordZoomOnintheupperleftcornerofthewindow.Fig.29:Manualzoom6.3.8.2GraphicalZoomItispossibletozoombyclickingtherightmousebuttonanddraggingtocreateaWindowoverthedesiredzoomareaofagraph.Whentherightmousebuttonisreleased,thegraphwillberedrawnwiththenewcoordinates.6.3.9ZoomOutZoomOutwillrestorethegraphtotheoriginalautoscaledvalues.Also,bydoubleclickingtherightmousebutton,thegraphwillreturntotheoriginalcoordinatescaling.ZoomOutisdeactivatedifthegraphiscurrentlynotzoomed.6.3.10LockScalingTheLockScalingfunctionallowssuccessivemeasurementstoberepresentedontheforceandtimeaxistothesamescaleindependentlyofthemeasuredmaximumandminimum.6.3.11UnlockScalingTheUnlockScalingallowstheLockScalingfunctiontobedisabledagain.DynoWareType2825A…Page722825A_002-195e-02.116.3.12Horiz.GridSelectingViewHoriz.Gridfromthemainmenu,orselectingtheicononthetoolbarwillredrawtheactivegraphwithhorizontalgridlinesenabled.Selectingtheoptionagainwilldisablethehorizontalgridlines.6.3.13Vert.GridSelectingViewVert.Gridfromthemainmenu,orselectingtheicononthetoolbarwillredrawtheactivegraphwithverticalgridlinesenabled.Selectingtheoptionagainwilldisabletheverticalgridlines.6.3.14ToolbarSelectingViewToolbarwilltogglethevisiblestateofthesystemtoolbar.Thefunctionaldescriptionsare:FileOpenHardwareEditAcquisitionCycleDocumentationSetupViewStartAcquisitionExportDataNewViewEditViewCursorMeanValue(Stats)DriftCompensationHorizontalGridsVerticalGridsLockScalingUnlockScalingZoomOutVoltmeterOscilloscopeCascadeViewsTileVerticalTileHorizontalHelpReference2825A_002-195e-02.11Page736.3.15StatusBarThestatusbarcanbeenabled/disabledfromtheViewStatusBarmenuselection.ThestatusbarrunsalongtheloweredgeoftheDynoWarescreen.Itisseparatedintotwosections.Theleftsideofthestatusbaroffersinformationonatopicselectedwhenthemouseismovedoveramenubarortoolbaritem.TherightsectionofthestatusbarshowsthestatusoftheCapsLockkey,theNumlockkey,andtheScrolllockkey.Fig.30:StatusBar6.4Analysis...6.4.1MeanValueByselectingAnalysisMeanvaluefromthemainmenuorbyclickingtheicononthetoolbarstatisticaldatacanbedisplayedonanactivey(t)timebasedgraph.Fig.31:MeananalysisThestatisticaldatawillappearonthebottomofthegraph.Statisticaldatawillinclude:Mean(average)value,DynoWareType2825A…Page742825A_002-195e-02.11Maximumvalue,MinimumValueandIntegralbetweentwouseridentifiedpoints.Fig.32:SamplestatisticaldataAdashedverticalbarwillfirstappearonthegraphalongwiththecursor.Thisverticallinewilltrackthemousemovementtosetthestartingpointfortheanalysis.Movetothedesiredstartingpositionthenleftclickthemouse.Next,adashedverticalbarwillappearonthegraphalongwiththecursor.Thisverticallinewilltrackthemousemovementtosettheendingpointfortheanalysis.Movetothedesiredendingpositionthenleftclickthemouse.Tochangeeitherthestartingpositionorendingpositionandupdatethestatisticaldata:1.)Movethemouseoverthedashedverticalcursorline.Thecursorwillchangeto2.)Clicktheleftmousebuttonanddragthelinetoanewposition(cursorwillchangetowhendragging)3.)Releasethemouse,thestatisticaldatawillbeupdated.TheMeanvalueanalysiscanbedisabledandthegraphrestoredtonormalbyreselectingthemenuchoice,orthetoolbaricon.ItisalsopossibletoquitwithESC.6.4.2CursorToolFortheanalysisofdataitishelpfultodisplaythex-andy-coordinates.PressingthetoolbariconorselectingAnalysisCursortoolfromthemenuwillenablethecursortool.Adashedverticalbarwillfirstappearonthegraphalongwiththecursor.Next,adashedverticalbarwillappearonthegraphalongwiththecursor.Tochangeeitherthestartingpositionorendingpositionandupdatethecursortooldata:1.)Movethemouseoverthedashedverticalcursorline.Thecursorwillchangeto2.)Clicktheleftmousebuttonanddragthelinetoanewposition(cursorwillchangetowhendragging)3.)Releasethemouse,thestatisticaldatawillbeupdated.Thecursorwindowcanbemovedanywhereonthedesktopbyleftclickingthemouseonthetoolbar,anddraggingtoanewlocation.Whenactivated,thecursortoolwillapplytoalltimebasegraphsy(t).Reference2825A_002-195e-02.11Page75Thecursortoolwilldisplayt1(timeatcursor1),t2(timeatcursor2),dt(t2–t1),1/dt(ins-1),1/dt(inmin-1),Y(t1),Y(t2),anddY.Fig.33:Cursortool6.4.3SignalDriftCompensationByselectingAnalysisSignalDriftCompensationfromthemainmenuorbyclickingtheicononthetoolbar,datacanbeadjustedtoremovetheeffectoflong-termthermaldriftandoffset.Thisisaccomplishedbycomputingastraightlinebetweenastartingandendingpoint,thensubtractingthislinefromtheselectedportionofthedataset.Alldatasetsonthecurrenttimeseriesgraphwillbecompensated.Thisfunctionisespeciallydesignedforresolvingtheproblemsofdriftinpiezoelectricmeasurementsystems.IntheOperatemode,thesignaldriftsawaywithaconstantslopeifthetemperaturedoesnotchangeduringthemeasurement.However,thedirection(ifnegativeorpositive)isunpredictable.Inshortmeasurementsorinmeasurementswithhighforcesthisdriftisusuallynegligible.Afterverylongmeasurementshoweverthisdriftisclearlyvisible.Measurementisstartedbeforeapplyingtheforceandcontinuesuntilthereisnolongeranyforceappliedtothetool,thedriftisvisibleasthesignalthatdoesnotfallbacktothezeroline.DynoWareType2825A…Page762825A_002-195e-02.11Theselectionofthestartingandendingpointsarecriticaltotheaccuracyofthecompensation.DriftCompensationonwillappearintheupperleftcornerthegraphtoidentifythedatasetasmodified.Whenselectingdriftcompensation:Adashedverticalbarwillfirstappearonthegraphalongwiththecursor.Thisverticallinewilltrackthemousemovementtosetthestartingpointforthecompensation.Movetothedesiredstartingpositionthenleftclickthemouse.Next,adashedverticalbarwillappearonthegraphalongwiththecursor.Thisverticallinewilltrackthemousemovementtosettheendingpointforthecompensation.Movetothedesiredendingpositionthenleftclickthemouse.Thefirstverticallineshouldbeplacedrightbeforetherisingedgeoftheforcecurve–wherethesignalstillliesonthezeroline.Thesecondlinehastobeplacedwherethereisnolongeranyforceapplied,i.e.wherethemeasuredsignalshouldlieagainonthezeroline.Fig.34:OriginalSignalReference2825A_002-195e-02.11Page77Fig.35:DriftcompensationappliedTochangeeitherthestartingpositionorendingpositionandupdatethecompensation:1.)Movethemouseoverthedashedverticalcursorline.Thecursorwillchangeto2.)Clicktheleftmousebuttonanddragthelinetoanewposition(cursorwillchangetowhendragging)3.)Releasethemouse,thedatasetwillbeupdatedandthegraphredrawn.Thechangeisonlytemporaryandcanbedisabledbyreselectingthemenuchoice,orthetoolbaricon.SelectFile→SaveModifiedFile(seeSection6.1.2)topermanentlyapplythechangestothedataset.6.4.4Smoothingon…Smoothingisusedto‘smooth’adataset.Smoothingisaformofdigitalfiltering.Thesmoothingoptionsare:1)MovingMean,2)MovingMedian.Eachisdiscussedinthefollowingparagraphs.SelectthechannelstoapplythesmoothingoptionfromthelistpresentedorpresstheAllChannelsbuttontoselectallavailablechannels.Thewords'SmoothingOn'willappearintheupperleftcornerofthegraphtoidentifythedatasetasmodified.DynoWareType2825A…Page782825A_002-195e-02.116.4.4.1MovingMeanAmovingmeanfilterisusedtosmoothanentiredatasetwhennoparticularfrequenciesaretobefilteredout.Thistypeoffiltergeneratesamovingaveragedatasetfromtheoriginalone,basedonauser-specifiedWindowsize.Thewindowsizespecifieshowmanyvaluestotheleftandrightofthecurrentvalueareaveraged.Thewindowsizemustbeanoddnumber,becausethecurrentvaluemustfallintheexactcenterofthewindow,withanevennumberofpointstotheleftandrightofit(ifyouenteranevennumber,thecalculationismadewiththenexthighernumber).Theaverageofallvaluesinthewindowiscalculated,andthisnumberisusedtoreplacethecurrentvalue.Thelargerthewindowsize,themoretheresultingdatasetissmoothed.TheFigurebelowillustratesboththemovingmeanandthemovingmedianfilters.Atthebeginningandtheendwhenthewindowsizewouldexceedthesampledvalues,thewindowsizeisreduced,startingandendingwithawindowsizeofCEIL(WindowSize/2).Fig.36:MovingMeanandMovingMedianfiltersReference2825A_002-195e-02.11Page796.4.4.2MovingMedianTheMovingMedianfilterissimilartotheMovingMeaninorderthatitalsousesamovingwindow.However,thismethodsortsthevalueswithinthewindowandreplacesthecurrentvaluewiththemedianvalue(i.e.,themiddlevalueinthesorteddatawindow).Themovingmediantypefilterisgoodforremovingsharpspikesinthedata.Thechangeisonlytemporaryandcanbedisabledbyreselectingthemenuchoice,orthetoolbaricon.SelectFile→SaveModifiedFile(seeSection6.1.2)topermanentlyapplythechangestothedataset.Kistlermeasurementequipmentisverysensitive.Some-timeswhatappearstobenoisecanbe"real"measuredphenomena.Careshouldbeexercisedinfilteringsoasnottoremoveimportantdata.Belowisanexampleofa"noisy"dataset.Fig.37:Originaldataset(nosmoothing)DynoWareType2825A…Page802825A_002-195e-02.11Fig.38:Smoothingon,movingmean(windowsize=20)6.4.5SmoothingoffSelectingAnalysisSmoothingOffwilldisableanyfilterscurrentlyappliedtothedataset.Acheckmarkonthemenuwillindicateifsmoothingiscurrentlyonoroff.6.4.6Filteringon…Filteringisusedtomodifyadatasetusingspecificfrequencycontentrequirements.Thetypeoffiltertousedependsuponthetypeofmodificationrequired.TheButterworthfilteringoptionsare:1)LowPass,2)HighPass,3)BandPass,and4)BandStop.Eachisdiscussedinthefollowingparagraphs.SelectthechannelstoapplythefiltertofromthelistpresentorpresstheSelectAllbuttontoselectallavailablechannels.Thewords'FilteringOn'willappearintheupperleftcornerofthegraphtoidentifythedatasetasmodified.Reference2825A_002-195e-02.11Page81Fig.39:Filteredsignal6.4.6.1LowPassForaLowPassfilter,theedgefrequencyisthefrequencyabovewhichallfrequenciesareattenuatedtosomedegree,andbelowwhichallfrequenciespassunfiltered.Essentially,alllowfrequenciesareallowedtopass,andallhighfrequenciesareremoved.Thespecifiedcutofffrequencyisthe–3db(halfpower)attenuationpointofann-thorderButterworthfilter.6.4.6.2HighPassForaHighPassfilter,theedgefrequencyisthefrequencybelowwhichallfrequenciesareattenuatedtosomedegree,andabovewhichallfrequenciespassunfiltered.Essentially,allhighfrequenciesareallowedtopass,andalllowfrequenciesareremoved.Thespecifiedcutofffrequencyisthe–3db(halfpower)attenuationpointofann-thorderButterworthfilter.6.4.6.3BandPassForaBandPassfilter,thelowercutofffrequencyanduppercutofffrequencydefinetherangeinwhichisfrequenciesareallowedtopass.Outsidetherange,thefrequenciesareattenuatedtosomedegree.Thespecifiedcutofffrequenciesarethe–3db(halfpower)attenuationpointsofann-thorderButterworthfilter.DynoWareType2825A…Page822825A_002-195e-02.116.4.6.4BandStopForaBandStopfilter,thelowercutofffrequencyanduppercutofffrequencydefinetherangeinwhichisfrequenciesareattenuatedtosomedegreed.Outsidetherange,thefrequenciesareallowedtopass.Thespecifiedcutofffrequenciesarethe-3db(halfpower)attenuationpointsofann-thorderButterworthfilter.6.4.6.5FilterSetup6.4.6.5.1EdgeFrequenciesThelowerandupperedgefrequenciesdefinethe-3dbcutofffrequenciesforthevariousButterworthfilterstypes.6.4.6.5.2FilterOrderThefilterorderspecifiesthenumberoftapsonthefilter.Ahigherfilterorderrequiresmorecomputationpowerbutprovidessharperfilteringcharacteristics.Thechangeisonlytemporaryandcanbedisabledbyreselectingthemenuchoice,orthetoolbaricon.SelectFile→SaveModifiedFile(seeSection6.1.2)topermanentlyapplythechangestothedataset.6.4.7FilteringoffSelectingAnalysisFilteringOffwilldisableanyfilterscurrentlyappliedtothedataset.Acheckmarkonthemenuwillindicateifsmoothingiscurrentlyonoroff.Reference2825A_002-195e-02.11Page836.4.8DataManipulationOffline…Thisfunctionallowsyoutousebasicmathematicalfunctionstochangedataalreadyacquiredforeachchannel.Thesourcechannels,operationanddestinationchannelofthecalculationmustbespecified.Theoutputchannelisoverwrittenwiththemanipulateddata!OnActivate/deactivatecalculationfunction.1.BaseFirstmeasurandtobeprocessed.2.BaseSecondmeasurandtobeprocessed.Thiscanalsobeusedtoenterconstants.ItisimportanttoconcludethenumericalentrywithRETURN.OperationMathematicaloperation.Thefollowingoperationsareavailable:addition,subtraction,multiplication,division,logg,lnh,exp(e)i,exp(10)j,sqrkandsqrtl.ResultChannelforoutputtingresultAddAddsanotherfunction.RemoveRemovesthechosencalculationfunction.Ifdataismanipulatedinthiswaythefollowingpromptisdisplayed:Confirmingcreatesa"*.bak.dwd"fileinthefolderinwhichthemeasurementdataissaved.Thisfilecontainstheunchangeddata,whereasthefilewiththesamenamebutwithoutthe".bak"extensioncontainsthechangeddata.gCommonlogarithmhNaturallogarithmiPowerofe(naturalexponential)jPowerof10kSquarelSquarerootDynoWareType2825A…Page842825A_002-195e-02.116.4.8.1ApplytoallcyclesinfileIfseveralcycleshavebeenacquiredbeforehand,thedatamanipulationcanbeappliedtoallcyclesofthisfile.6.5Tools...6.5.1Voltmeter…TheVoltmeterisatroubleshootingtoolthatnumericallydisplaysthevoltagesattheinputstotheA/Dcard.SelectingVoltmeterfromtheToolmenustartsthemeter.AnyamplifiersconfiguredforMeasureModeOnStartAcquisitionareswitchedtotheOperatemodeautomaticallywhenthevoltmeterisstarted,andarereturnedtoresetwhenthetoolisexited.Tostoptheacquisition,presstheStopbutton.TorestartanacquisitionpressRun.Fig.40:VoltmeterToolThegridshowsthechannelsconfiguredinthesystem,theiractivestate,andtheconfiguredlabel.Toenable/disableachannelusetheOncolumncheckbox.ThevoltagedatacanbeselectedtoappearinVolts[V]orMillivolts[mV].TheVoltmetercanberunatthesametimeastheOscilloscopefunction,butotherdataacquisitionfunctionsaredisabledwhiletheVoltmeterisactive.Reference2825A_002-195e-02.11Page856.5.2Oscilloscope…TheOscilloscopeisatroubleshootingtoolthatgraphicallydisplaysthevoltagesattheinputstotheA/Dcard.SelectingOscilloscopefromtheToolmenustartsthescope.AnyamplifiersconfiguredforMeasureModeOnStartAcquisitionareswitchedtotheOperatemodeauto-maticallyatthestartoftheoscilloscope,andarereturnedtoresetwhenthetoolisexited.Tostoptheacquisition,presstheStopbutton.TorestartdataacquisitionpressRun.Fig.41:OscilloscopetoolThegridshowsthechannelsconfiguredinthesystem,theiractivestate,andtheconfiguredlabel.Toenable/disableachannelusetheOncolumncheckbox.ThechannelcolorisdisplayedintheOncolumn.ThevoltagescaleandtimescalecanbeselectedfromtheVolt/Div.andSec./Div.Boxes.TheOscilloscopecanberunatthesametimeastheVoltmeterfunction,butotherdataacquisitionfunctionsaredisabledwhiletheOscilloscopeisactive.DynoWareType2825A…Page862825A_002-195e-02.116.6Options...6.6.1UserModeTheUserModeallowsthesoftwareoperationtoberestricted.ThedefaultusermodeisSupervisor.6.6.1.1SupervisorNooperationrestrictionsaremadeintheSupervisormode.Torestrictaccesstosoftwareanddeviceconfigurations,selecttheOperatormode.Thedefaultpasswordis"DynoWare"(capital'D'and'W',lowercaseforotherletters!).6.6.1.2OperatorNofunctionalsettingscanbemadeinthismode(Changestodevicesconfigurations,etc.canonlybemadeinthesupervisormode).ToswitchfromUsermodetooperatormodeapasswordisrequired.6.6.1.3ChangePasswordFig.42:ChangingpasswordTochangetheOperator/SupervisormodepasswordselecttheOptionsUserModeChangePasswordmenuchoice.Youwillneedtoentertheoldpassword,andenterthenewpasswordtwiceidenticallyforthenewpasswordtobeaccepted.Passwordsarecasesensitive.Thedefaultpasswordis"DynoWare"(capital'D'and'W',lowercaseforotherletters!).Reference2825A_002-195e-02.11Page876.7Window...Whenagraphisopen,theWindowmenuappearsinthemenubar.TheWindowmenuisforcontrollingthepositionofthegraphs,andisusefulwhenmanydifferentgraphsareopenonthescreen.6.7.1CascadeArrangeallopengraphsstaggeredandoverlappingeachother.6.7.2TileHorizontalArrangeallopengraphstobenon-overlappingtiledhorizontally.6.7.3TileVerticalArrangeallopengraphstobenon-overlappingtiledvertically.6.7.4ArrangeIconsArrangesallminimizedgraphsiconsinthelowerleftcorneroftheapplication.6.7.5CloseAllClosesallopengraphsandfiles.6.7.6<openwindowslist>Showsalistofallopengraphs.Selectaniteminthelisttoactiveaspecificgraph.DynoWareType2825A…Page882825A_002-195e-02.116.8Help...6.8.1HelpTopicsTheDynoWarehelpmenuisavailablebyselectingHelpTopicsfromtheHelpmenu,orbypressingF1atanytime.DynoWareusesstandardHTMLhelpformatthroughthedefault-configuredbrowser(seesection1.1formorein-formation).6.8.2SelectLanguageDynoWareofferstwolanguages(GermanandEnglish).Anychangeismadewhentheprogramisstartedforthefirsttime.6.8.3AboutDynoWareTheAboutDynoWareboxprovidesinformationabouttherunningversionoftheapplication,andtheproducttypenumber.Bepreparedtoprovidethisinformationwhenrequestingtechnicalsupport.Appendix2825A_002-195e-02.11Page897.Appendix7.1GraphsManipulatingdatausinggraphsissimpleandquickwithDynoWare.Whenatrialisopenedoneormoregraphsappearusingthedefaultconfiguration(seeSection6.3.3Setup…).Thegraphscanbeeditedforcontent,display,andtitles.141516171819202122230400.00800.001200.001600.002000.002400.002800.00-80.00-60.00-40.00-20.00020.0040.0060.0080.00100.00Time[s]BohrenLehrwerkstattCycleNo.:1ZoomonSmoothingon>>>Fx[N]:Y2Fy[N]:Y2Fz[N]:Y1DriftCompensationonY1Y2Fig.43:Typicaltimebasedy(t)graphGraphinformationArea:Zoom,Smoothing,Filtering,andDriftCompensationZoomselection=rightclickanddragZoomout=doublerightclickSecondy-AxisLegend,showslabel,units,andaxisCyclemoveforward,cyclemovebackwardbuttons.MainTitle(doubleclicktoedit)CurrentcyclenumberVerticaldashedbarsfordriftcompensation,cursor,ormeanvaluecalculations.GraphicaldataDynoWareType2825A…Page902825A_002-195e-02.117.2LanguageSelectionAllofthesupportedlanguagesaredisplayedinaboxbypressingCtrl+Alt+S.Youcanchooseadifferentlanguage,whichwillbeloadedthenexttimetheprogramisstarted.7.3ShortcutKeySummaryKeyCommandF1HelpAlt+DViewDocumentationAlt+EAcquisitionEditAlt+HAcquisitionHardwareAlt+SAcquisitionStartCtrl+Alt+SSelectLanguageCtrl+PPrintReportCtrl+LReportLayout(notdocumented)Ctrl+TABCyclethroughOpenWindows(forwards)Ctrl+SHIFT+TABCyclethroughOpenWindows(backwards)RightMouseDragongraphZoomInongraphRightMouseDoubleClickongraphZoomOut(ifpreviouslyzoomedin)Appendix2825A_002-195e-02.11Page917.4ModifyingtheReportLogoIfyouwanttomodifythereportprint-outtohaveyourcompanylogo,performthefollowingsteps:Replacethefileprnlogo.bmp,(bydefault:C:\Programs\Kistler\DynoWare).Namethefileofyourlogoprnlogo.Notes:1.Theimagefileextensiondoesnotneedtobeentered.DynoWarewillsearchfor"bmp","wmf","pcx","tif"and"jpg"imageextensionsautomatically(andsupportsthesetypesofimages).2.Therecommendedimagesizeis362(width)by67(height)pixels.Imageswillbescaledtofitandcenteredinthelogoareaofthereport.3.Don’tdeletetheoriginalprnlogo.bmpfilebutrenameit.7.5ExampleFilesFilenameDescriptionmessdat.dwdDrillingsteelmessdat1.dwdmessdat3.dwdGeneralforceapplicationswept_sine.dwd1channel,sine,startingwithlowandendingwithhighfrequency(sweptsine),forfilterexperimentsThisdataissavedinthefollowingdefaultfolder:C:\Kistler\DynoWare\DataDynoWareType2825A…Page922825A_002-195e-02.118.TechnicalDataofDAQ-SystemsType5697A8.1GeneralDataDimensionsmm208x70x249Weightkg2,15Operatingtemperaturerange°C0…50Min./max.temperature°C–10/608.2PowerSupplyElectricalisolation(max.40V)betweeninputandsupplyvoltageInputvoltagerangeVDC10…36PowerconsumptionVA58.3A/DConversionNumberofchannels28mResolution(eachchannel)bits16Inputvoltageranges(software-selectable)V0,1/0,2/0,51/2/5/10InputvoltageV20Samplingrate(software-selectable)Maxwith1channelMaxwith3channelsMaxwith8channelsMaxwith14channelskS/skS/skS/skS/skS/s1000100033312571Error(conversion)%<0,1Zeroerrorinrange1V/2Vinrange5V/10VmVmV12Inputnoiseinrange<1Vinrange>1VmVRMSmVRMS24mDynoWareType2825AandDynoWareUpdateType2825EcurrentlyonlycontroloperationofonemultichannelchargeamplifieronDAQ-SystemType5697.DAQ-SystemType5697iscapabletoacquire28channelsmaximum.TechnicalDataofDAQ-SystemsType5697A2825A_002-195e-02.11Page938.4ConnectionsUSB2.0(high-speed)USBin(uplink,tothePC)USBout(downlink,unused)TypeB,femaleA,female8.5RemoteControl(Digitalinputand12Vsupply)RemoteMeasureandTriggerwith10kpullupto+5VConnectortypeD-sub9fInputlevelHigh(/TriggerInput,/MeasureInput)LowVDCVDC>1,5<1MaximuminputvoltageVDC30SupplyVDC+12DynoWareType2825A…Page942825A_002-195e-02.119.MeasuringChainUsedFig.44:CableconceptforDynoWareType2825A…withA/DacquisitioncardTypes2855A4and2855A5MeasuringChainUsed2825A_002-195e-02.11Page95Fig.45:CabelconceptforDynoWareType2825A…withDAQ-SystemType5697AFig.46:InterfacecablesDynoWareType2825A…Page962825A_002-195e-02.1110.Index11700A111A2.................................................2455011..............................................................455015..............................................................455017..............................................................415018..............................................................465019..............................................................415070..............................................................525080..............................................................565223..............................................................485237..............................................................515697(USB2533)............................................19AA/DCardConfiguration................................20A/DCardNumber.........................................22About............................................................88Acquisition.....................................................38AmplifierSelection.........................................40AnalogInput..................................................23Analysis.........................................................73ASCIIFile.......................................................33BBackupFile....................................................32BandPassFilter..............................................81BandStopFilter.............................................82BurstMode....................................................39CCalculationsRCD...........................................49Channels........................................................62Chargeamplifiers...........................................27Clipboard,Copyto........................................38Comments.....................................................68ComputerManagement................................26Configuration................................................32ConfigurationA/DCard................................20Connectingcables..........................................23ContinuousCycles.........................................61CSVFile.........................................................33CursorTool....................................................74CuttingForceDocumentation........................69Cycle..............................................................61DDAQSystemType5697................................19DataAcquisitionCard....................................17DataManipulation.........................................63DataManipulationoffline..............................83Demo-Board..................................................22DeviceManager.............................................26DifferentialMode...........................................21Documentation..............................................68Dongle...........................................................16DualModeModule........................................56EEdgeFrequency..............................................82Edit................................................................60EditLabels......................................................70EditView........................................................66Examplefiles..................................................91Exit.................................................................38Export............................................................33ExportCycle...................................................61ExporttoExcel...............................................33FFilemenu.......................................................31FilterOrder....................................................82FilterSetup.....................................................82Filtering..........................................................80GGraph.............................................................89Grid................................................................72HHardware.......................................................38HASPKey.......................................................16Help.................................................7,8,11,88HighPassFilter...............................................81IIEEE-488........................................................45Instacal...........................................................20Installation.....................................................14InstallationofA/Dcard..................................17InstallationSoftware......................................14LLabels.............................................................70Languageselection........................................90LanguageSelection........................................88Licenseagreement...........................................9LLViewer.......................................................362825A_002-195e-02.11Page97LoadConfiguration........................................32LockScaling....................................................71Logo...............................................................91LowPassFilter................................................81MM.U..........................................................41,56MeanValue....................................................73MeasuringChain............................................94MovingMean.................................................78MovingMedian..............................................79Multicomponentmeasurement.................42,53Multicomponentmeasurement.......................58OOpenFile........................................................31Operator........................................................86Oscilloscope...................................................85Otheramplifiers..............................................47PParameter.......................................................61Password........................................................86PC-CARD-DAS16/16.....................................18PCIM-DAS1602/16........................................17Piezotron........................................................56Pretrigger.......................................................63Print...............................................................35Printpreview..................................................36PrintSetup......................................................38QQuickstart......................................................28RRCDType9123/9124..................................48RCDType9125..............................................51RealtimeScreening.........................................61RealtimeUpdate.............................................61RemoteControl........................................27,93ResetColor.....................................................70ResetFont......................................................70RS-232Cinterfacecable.................................25SSafety.............................................................11SaveConfiguration........................................32Savemodifiedfile..........................................31SelectionofAmplifier.....................................40SetupView....................................................68Shortcutkey..................................................90ShowHardwareDialog..................................40SignalCable...................................................23SignalDriftCompensation.............................75Single-EndedMode.......................................22Smoothing.....................................................77Softwareinstallation......................................14Start...............................................................64StatusBar......................................................73Superimposeview..........................................67Supervisor......................................................86Support............................................................8Systemrequirements......................................13TTechnicalDataType5697A...........................92Toolbar..........................................................72Tools..............................................................84Trigger...........................................................62TriggerDelayTime........................................61UUnlockScaling...............................................71USBDongle...................................................16USBSetup5018.............................................47USBSetup5080.............................................57USB-RS232CConverter................................25Usermode.....................................................86VView..............................................................66Viewedit.......................................................66ViewSetup....................................................68Voltmeter......................................................84WWarranty.........................................................9Window.........................................................87ZZoom.............................................................70
本文档为【Kistler测力仪软件DynoWare使用说明书】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
机构认证用户
壹笑先生
致力于服务广大学子、教师、社考人员等一份学习的资料!
格式:pdf
大小:993KB
软件:PDF阅读器
页数:0
分类:互联网
上传时间:2020-09-30
浏览量:175