首页 宝典gsm基站子系统

宝典gsm基站子系统

举报
开通vip

宝典gsm基站子系统宝典gsm基站子系统 GSM基站子系统 维护参考手册 Revision,History Date Version Issued,By Approved,By Changes 10/20/00 1.0 Rainer,Qu original 目,,,,,,,,,,录 1 GSM基站子系统维护参考流程………………3 2 GSM基站室内部分维护参考流程……………10 3 GSM基站室外部分维护参考流程……………12 附录A,,INCELL,GCLK,calibration,guideline,……………...

宝典gsm基站子系统
宝典gsm基站子系统 GSM基站子系统 维护参考手册 Revision,History Date Version Issued,By Approved,By Changes 10/20/00 1.0 Rainer,Qu original 目,,,,,,,,,,录 1 GSM基站子系统维护参考流程………………3 2 GSM基站室内部分维护参考流程……………10 3 GSM基站室外部分维护参考流程……………12 附录A,,INCELL,GCLK,calibration,guideline,……………,,14 附录 B,,MCELL,GCLK,calibration,guideline…………………17 附录C,,仪器、仪表矫正 标准 excel标准偏差excel标准偏差函数exl标准差函数国标检验抽样标准表免费下载红头文件格式标准下载 …………………………………21 附录D,,除锈、防锈标准………………………………………22 附录E,,接地、避雷标准………………………………………24 附录F,,馈线防水胶带缠绕标准………………………………29 附录G,,馈线接头制做注意事项………………………………31 附录H,,天馈系统馈线走线标准………………………………33 附录I,,天线维护质量标准……………………………………36 附录J,天线尾线的质量标准…………………………………40 附录K,桅杆的质量标准………………………………………42 附录L,,走线架质量标准………………………………………44 1( GSM基站子系统维护参考流程 1.1,,正式调测前的准备工作 第一项 正式调测前的准备工作 执行, 未执 行, 要求 切记严格按照流程进行操作,一旦发生漏、误操作,可能导致后面的全部努力付之东流。另外对于在准备过程发现的问题及时进行处理和记录。 对于TCU)SCU和DRCU设备的准备工作 1. 显示基站站号和所有载频的状态 MMI-RAM>disp_site MMI-RAM>state,#,dri,*,*,,,,,,,,,‘‘#’’对应站号 2. 锁住所有载频 MMI-RAM>lock,#,dri,$,$,,,,,,,,,,‘‘#’’对应站号,’’$,$’’对应载 频号 3. 在BTS中清除所有载频的调测值 MMI-RAM>clear_cal_d,#,dri,$,$,,‘‘#’’对应站号,’’$,$’’对应载频 号 4. 对所有载频做硬件复位 操5. 对所有载频在CINDY软件上点击“Prepare,RCU”按扭进入调测状态,如不能正 常进入调测状态的,则进行重复操作,最后确定是载频故障的,进行相应更换。 作 对于TCUB设备的准备工作 流1. 显示基站站号和所有载频的状态 MMI-RAM>disp_site 程 MMI-RAM>state,#,dri,*,*,,,,,,,,,‘‘#’’对应站号 2. 锁住所有载频 MMI-RAM>lock,#,dri,$,$,,,,,,,,,,‘‘#’’对应站号,’’$,$’’对应载 频号 3. 在BTS中清除所有载频的调测值 MMI-RAM>clear_cal_d,#,dri,$,$,,‘‘#’’对应站号,’’$,$’’对应载频 号 4. 对所有载频指定时钟0(用9-25,WAY,RSS线接至TCUB,TTY口,然后键入以下 命令) MMI-RAM>tcu_clock,0 5. 对所有载频在CINDY4软件上点击“Carrier,Setup”按扭进入调测状态,如不 能正常进入调测状态的,则进行重复操作,最后确定是载频故障的,进行相应更换。 记录 请按表格1.1记录。 表格1.1 设备名称及位置 故障信息 处理情况 1.2,,DRI接收电平补偿值调整 第二项 DRI接收电平补偿值调整 执行, 未执行, 要求 按照流程要求,逐个完成每个载频的接收电平补偿值调整,对于调整过程中反应出来的 载频、射频器件问题,及时进行处理并记录,同时对调测结果进行记录。 操作 操作流程如下: 1. 连接信号源至基站架顶天线连接端口,设置信号源输出电平值为,65.2dBm+测试RF线流程 损耗 2. 运用CINDY软件(TCUB用CINDY4)的接收补偿调整模块,对每个载频进行调测。 3. 如果接收补偿值有80值出现,必须重调。 记录 调测值请按表格2.1记录,调测中遇到的问题及处理情况请按表格2.2记录。 表格2.1 RXA RXB CELL DRI MAX MIN STEP MAX MIN STEP 0,0 0,1 0,2 CELL1 0,3 0,4 0,5 0,6 0,7 1,0 1,1 1,2 1,3 CELL2 1,4 1,5 1,6 1,7 2,0 2,1 2,2 2,3 CELL3 2,4 2,5 2,6 2,7 表格2.2 设备名称及位置 故障信息 处理情况 1.3,,载频架顶发射功率调整 第三项 载频架顶发射功率调整 执行, 未执行, 要求 按照载频架顶功率值一级HC为15W,两级HC为10W的要求调整每个载频的发射功 率,如有问题(功率不能调整致要求值)必须马上处理并记录。 操作 操作流程如下: 1. 连接功率计至架顶相应射频通道。 流程 2. 运用CINDY(TCUB用CINDY4)的功率调整模块,对每个载频的发射功率进行调整。 3. 对于功率不能调整致要求值的载频,进行更换或处理相关射频通道,直到调至要求值。 记录 调整结果请按表格3.1记录,故障处理情况请按表格3.2记录。 表格3.1 CELL DRI 输出功率 偏移值 CELL1 0,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 1,0 1,1 1,2 1,3 CELL2 1,4 1,5 1,6 1,7 2,0 2,1 2,2 2,3 CELL3 2,4 2,5 2,6 2,7 表格3.2 设备名称 故障信息 处理情况 1.4天馈线驻波比测试 第四项 天馈线驻波比测试 执行, 未执行, 要求 测试每个天馈线的驻波比值,对测试值大于1.4的天馈线进行处理,记录测试结果和处理结果。 操作 具体流程如下(可结合第三项一起操作): 1. 连接功率计至架顶相应大馈线上。 及 2. 连接计算机至大馈线对应之载频上。 流程 3. 运用CINDY(TCUB用CINDY4)的驻波比测试模块,测试大馈线的驻波比。 4. 对达不到要求的天馈线进行处理。 记录 测试结果请按表格4.1记录,故障处理情况请按表格4.2记录。 表格4.1 天线编号 正向功率 反向功率 驻波比 1-1-1 1-1-2 1-2-3 1-2-4 2-1-1 2-1-2 2-2-3 2-2-4 3-1-1 3-1-2 3-2-3 3-2-4 表格4.2 设备名称 故障信息 处理情况 1.5时钟校准 第五项 时钟校准 执行, 未执行, 要求 按照操作流程对基站时钟板进行校准,对校准未能达到要求的时钟板进行处理并记 录。INCELL校准要求为16.384MHz+0.8Hz,MCELL校准要求校准增益为 0~1.5之间。对于达不到要求的时钟及时更换并要求在10~30天内再次前往校准, 操作步骤严格按照本流程第五项之规定。 操作 INCELL校准流程:(见附件A 流程 《INCELL,GCLK,calibration,guideline》) Mcell校准流程:(见附件B《MCELL,GCLK,calibration,guideline》) 记录 校准情况请按表格5.1记录,如果本次校准结果正常,则只需记录“本次校准记录” 项,否则必须按第五项之要求填写“第N次处理记录”。 表格5.1 设备类型本次校准上次校准本次校准本次校准结果评 (请打勾设备位置 时间 时间 前值 值 价 选择) INCELL0,0 (主) 本次校准 0,1 记录 MCELL,(备) 第(,,) 次处理记 录 第(,,) 次处理记 录 第(,,) 次处理记 录 第(,,) 次处理记 录 1.6遗留问题记录 第六项 遗留问题记录 执行, 未执行, 要求 对巡检过程中反应出的问题进行总结,对遗留问题必须说明原因,同时制定解决 方案 气瓶 现场处置方案 .pdf气瓶 现场处置方案 .doc见习基地管理方案.doc关于群访事件的化解方案建筑工地扬尘治理专项方案下载 和 预定解决时间。 操作 流程 记录 请按照表格6.1记录。 表格6.1 序号 遗留问题描述 遗留原因 解决方案及解决时间 2.,GSM基站室内部分维护参考流程 序项目 要求及周期 执行情况 说号 请打 明 1. 环境卫生巡检 [壹次/2月] 执行 未执行 1.1. 机房保洁要求 [壹次/2月] 执行 未执行 如遇不明情 况,请与管1.1.1. 要求各种设备外壁、机房内各面 完全实施 好 一般 差 理人员联系无尘、无渍 后再实施。 1.1.2. 要求机房内无杂物,机房外无与 完全实施 好 一般 差 本机房相关物品。 1.1.3. 空调过滤网清洗,或更换 完全实施 好 一般 差 1.2. 环境检查 [壹次/2月] 执行 未执行 未执行 1.2.1. 检查机房各面是否完好,如有裂 记录并预处理 正常 略次 严重 如果情况严 缝、坑洞情况必须指出 重必须及时 处理,同时1.2.2. 检查机房是否有漏水现象、痕迹 记录并预处理 正常 略次 严重 如果局方有1.2.3. 检查门窗是否有破损现象 记录并预处理 正常 略次 严重 需求,必须1.2.4. 检查空调下水管是否畅通 记录并预处理 正常 略次 严重 配合局方施1.2.5. 检查机房内外联系点,门窗除 记录并预处理 正常 略次 严重 工人员进行外,是否具备防水、防火、防盗处理 功能。,联系点指:馈线进线 孔、电源线&接地线进线孔、空因维护人员忘调内外机联系孔, 记关闭窗门而1.2.6. 人员撤离前所有门窗是否关闭 确保 关 未关 造成基站设备 损坏或丢窃现 象,后果由他 负全责 1.3. 必备辅助设备检查 [壹次/2月] 执行 未执行 1.3.1. 检查照明设备是否完好齐备 记录并预处理 是 否 1.3.2. 检查壁电能否供电 记录并预处理 是 否 1.3.3. 检查消防设备是否配备 记录数量和有效期 是 否 1.3.4. 检查卫生设备是否配备 记录种类、数量 是 否 1.3.5. 检查梯子是否配备 记录数量 是 否 2. 蓄电池巡检 周期见分项 执行 未执行 必须配合局 方进行电池2.1. 蓄电池单体次序标识,作为蓄电 [壹次/2月] 标识 未标识 组全部或部池单体测试、维护的唯一标准。 分更换 对于未标识的蓄电池单体,必须检查并补充 进行标识。标识原则从左到右, 至上而下。 2.2. 蓄电池外观检查 [壹次/2月] 执行 未执行 2.2.1. 有无单体破损 记录 好 差 2.2.2. 有无漏液现象 记录并预处理 好 差 2.2.3. 连接件是否完好 记录 好 差 2.2.4. 接口有无松动现象 记录并处理 好 差 2.2.5. 盖板是否无损 记录 好 差 2.2.6. 整体安装是否牢靠 记录并处理 好 差 2.3. 电池连接点温度测量 [壹次/2月] 执行 未执行 2.4. 蓄电池电导值测试。 [贰次/年] 执行 未执行 2.4.1. 完成附表作业,同时对于测试结 完全实施 正常 略次 严重 果不和格的电池单体必须 报告 软件系统测试报告下载sgs报告如何下载关于路面塌陷情况报告535n,sgs报告怎么下载竣工报告下载 指 出 3. 电源、空调设备低级维护 [壹次/2月] 执行 未执行 3.1. 三相进 电电压测量 实施并预处理 正常 异常 3.2. 模块电源架是否有告警现象 记录 无 有 3.2.1. 检查模块是否有退出服务或告警 记录并更换故障件 无 有 问题 3.3. 检查交流配电盒、直流配电架各 实施并查明原因及正常 异常 连接点的温度 处理 3.4. 检查是否有无关设备连接至机房 实施并查明原因 无 有 交流配电箱或直流配电架 3.5. 空调是否正常运作,检查有无告 记录 正常 异常 警现象 3.6. 检查空调断电自启动是否正常 实施并记录 正常 异常 4. 室内接地情况检查 [壹次/2月] 执行 未执行 雷雨季加强 4.1. 检查各类设 备俱已正确接地 记录并整改 是 否 4.2. 接地地阻测量 记录并查明原因 正常 异常 3.,GSM基站室外部分维护参考流程 序项目及内容 要求及周期 执行情况 说明 号 请打 1 天馈线部分检查 [壹次/2月] 执行 未执行 雷雨季节加强 1.1 天线安装是否牢固可靠 检查并预加固处理 是 否 及时调整同扇1.2 天线俯角检查,要求同扇区天线俯角误 测量并记录、调整 检查 未检查 区倾角不一致天线 差小于1 及时调整同扇1.3 天线方向角检查,要求同扇区天线朝向 检查并记录、调整 检查 未检查 区不平衡天线 误差小于5 1.4 检查并记录天线型号、工作频段、安装 检查并记录 检查 未检查 平台、高度 一1.5 清洁天线 完全实施 好 差 般 1.6 检查天线外观有否损坏及漏水现象 检查并记录 是 否 配合更换处理 及时处理连接1.7 检查天线、尾巴线、大馈线三者之间连 检查并处理 是 否 点牢固性、密封性不佳问题 接点是否牢靠及密封 未标或错标,1.8 天馈线标识及检查 标识及检查 正确 不正确 重新标识 1.9 通过检查馈线两端标号来计算大馈线长 检查并记录 检查 未检查 度 配合进行更换1.10 检查大馈线外形有否磨损、变形、老检查并记录 无 有 处理 化、扭曲现象 及时处理未捆1.11 尾巴线是否固定捆绑在桅杆或悬壁上 检查并处理 是 否 绑或捆绑不佳情况 1.12 大馈线固定是否达到要求( 1米1个馈检查并记录 是 否 线夹) 1.13 大馈线三点接地是否达到要求 检查并记录 是 否 1.14 大馈线入室处是否达到密封的要求 检查并记录 是 否 1.15 大馈线入室处是否具备回水湾 检查并记录 是 否 2 铁塔/桅杆检查 [壹次/2月] 执行 未执行 雷雨季节加强 2.1 避雷系统是否符合要求 检查并记录 是 否 2.2 爬梯或用于固定馈线的角度是否牢固可 检查并预处理 是 否 靠 2.3 铁塔 /桅杆是否牢固可靠 检查并预加固处理 是 否 2.4 铁塔 /桅杆是否符合室外防腐防锈要求 检查并记录 是 否 3 防雷接地检查 [壹次/2月] 执行 未执行 雷雨季节加强 3.1 接地线和接地排是否具备防水、防绣处检查并预处理 是 否 理 3.2 测试接地地阻测试达到要求 检查并 分析 定性数据统计分析pdf销售业绩分析模板建筑结构震害分析销售进度分析表京东商城竞争战略分析 原因 是 否 4 其他 [壹次/2月] 执行 未执行 一4.1 环境卫生保持整洁 完全实施 好 差 般 4.2 楼顶下水道是否畅通 完全实施 是 否 附录A,,INCELL,GCLK,calibration,guideline 1 Calibrating,the,GCLK 1.1 Introduction Follow,this,procedure,to,calibrate,the,GCLK,in,the,field.,The,GCLK,must,be,calibrated,whe n,more,than,one,frame,slip,per,hour,is,observed,or,when,the,GCLK,is,phase,locked,to,the, E1/T1,serial,data,stream,and,the,system,requests,calibration., 1.2 Test,equipment The,following,test,equipment,is,required:, , An,IBM-compatible,personal,computer,(PC)., , A,9-,to,25-way,cable., , A,Rubidium,standard., , Universal,counter,-,Hewlett,Packard,Model,HP5385A,or,equivalent., , Screened,coaxial,cable,-,BNC,to,2,mm,multicontact,AG,connector., , New,calibration,sticker(s)., , A,non-ferrous,tuning,tool., 1.3 Commands The,following,commands,must,be,used,to,calibrate,the,GCLK:, Command, Function, disp_equipment, Displays,the,active,equipment,at,a,specified,site., state, Displays,the,status,of,specified,devices,or,functions., chg_element,phase_lock_gcTurns,the,phase,lock,function,on,or,off,,where,,is,0,f lk,,, or,off,and,1,for,on,,and,,is,the,site,id., disp_element,phase_lock_gShows,the,status,of,the,phase,lock,function,,is,t clk,, he,site,id., clear_gclk_avgs,,, 1.4 Procedure Before,attempting,this,procedure,record,the,board,serial,number,,date,of,last,calibration,and,present,frequency,on,the,calibration,record,shown,at,the,end,of,this,section,,and,remove,the,old,calibration,stickers,from,the,GCLK,front,panels., Proceed,as,follows:, 1. Connect,the,serial,A,port,on,the,PC,to,a,GPROC,TTY,port,using,the,9-,to,25- way,cable., 2. At,the,PC,start,the,terminal,emulator,program., 3. Connect,the,output,from,the,10,MHz,standard,to,the,reference,input,of,the,frequenc y,counter,,select,external,standard., 4. Set,the,frequency,gate,time,to,10,second,and,set,the,display,to,give,10,significant,d igits., 5. Check,to,see,if,phase,lock,is,on,,at,the,CUST,MMI,prompt,type:, disp_element,phase_lock_gclk, is:, Where:, 0,to,40,or,"bsc", , This,gives,the,status,of,phase,lock,at,the,site,,0,is,shown,for,phase,lock,off,and,1,is, shown,for,phase,lock,on. 1. If,phase,lock,is,on,,at,the,CUST,MMI,prompt,type:, chg_element,phase_lock_gclk,0, is:, Where:, 0,to,40,or,"bsc", , This,turns,off,the,phase,lock,to,the,selected,site. 1. At,the,CUST,MMI,prompt,type:, disp,equip This,gives,the,device,id,of,the,GCLKs. 1. At,the,CUST,MMI,prompt,type:, stateGCLK This,displays,the,status,for,the,GCLK. 1. At,the,CUST,MMI,prompt,type:, clear_gclk_avgs,, is:, Where:, 0,to,40,or,"bsc", , , 0,or,1, This,clears,the,LTA,values,for,the,specified,GCLK. 1. Connect,the,frequency,counter,to,the,front,panel,16.384,MHz,connection,of,the,GCL K., 2. Connect,the,cable,to,the,input,port,of,the,frequency,counter,and,the,jack,plug,end, to,the,front,panel,of,the,GCLK,16.384,MHz,output,and,ground,respectively., 3. Using,a,non- ferrous,tuning,tool,,adjust,the,potentiometer,labelled,FREQ,ADJUST,on,the,GCLK,t o,16.384,MHz.,The,GSM,specified,tolerance,is,+/- ,0.8,Hz,,although,it,is,desirable,(and,should,be,possible),to,adjust,the,frequency,mo re,accurately,than,this.,This,reads,as,16.384,000,00,on,the,frequency,counter.,Adjust ing,the,potentiometer,clockwise,increases,the,frequency,and,anticlockwise,decrea ses,the,frequency., 4. Repeat,step,7,to,step,12,if,the,other,GCLK,is,to,be,calibrated., 5. If,phase,locking,of,the,GCLK(S),at,the,site,is,required,type:, chg_element,phase_lock_gclk,1, This,turns,the,phase,lock,on,for,the,specified,site. 1. Place,a,new,calibration,sticker,,indicating,the,date,of,calibration,,over,the,potentio meter,labelled,FREQ,ADJUST,on,each,calibrated,GCLK., 1.5 GCLK,calibration,record,form The,GCLK,calibration,record,form,is,shown,below:, 附录B,,MCELL,GCLK,calibration,guideline 1 Calibrating,the,MCUF,(GCLK) 1.1 Introduction This,procedure,explains,how,to,calibrate,the,Oven,Controlled,Crystal,Oscillator,(OCXO),in,the,GCLK,on,the,MCUF,in,the,Horizonmacro,product,at,a,BSS,site., 1.2 When,to,calibrate,the,GCLK This,calibration,procedure,is,to,be,used,on,the,following,occasions:, , When,more,than,one,frame,slip,per,hour,is,observed,at,the,OMC, , Whenever,calibration,is,required.,(Display,the,active,alarms,for,a,site,,if,calibration ,is,required,,there,will,be,an,alarm,stating,this.), 1.3 Test,equipment,required The,test,equipment,required,to,carry,out,the,GCLK,calibration,is,as,follows:, , An,IBM,compatible,personal,computer,(PC)., , A,9,to,9,way,TTY,cable., , Caesium,or,Rubidium,clock,standard,with,1,or,10,MHz,output,frequency., , Universal,counter,with,external,reference,,for,example,,the,Hewlett,Packard,mode l,HP5385A,or,equivalent., 1.4 Setting,up,for,calibration To,prepare,the,MCUF,(gclk),for,calibration,,carry,out,the,following,steps:, 1. Connect,the,serial,A,port,of,the,PC,to,the,MCU,TTY,port,using,the,9,to,9,way,TTY,ca ble., 2. Start,the,terminal,emulator,program., 3. Connect,the,output,from,the,10,MHz,standard,to,the,reference,input,of,the,frequenc y,counter,,select,external,standard., 4. Set,the,frequency,gate,time,to,10,seconds,and,the,display,to,10,significant,digits., 5. Connect,the,test,cable,extracting,the,8,kHz,output,signal,from,the,front,of,the,MCUF ,to,the,input,of,the,counter., Pin,1,-,Ground,(top,pin) Pin,3,-,8,kHz,signal,(bottom,pin) Figure,1-1,illustrates,how,the,equipment,is,to,be,connected,to,the,unit,under,calibration., Figure,1-1 ,GCLK,calibration,-,test,connections 1.5 Test,Procedure 1. At,the,MMI-RAM,1015,prompt,type:, gclk_cal_mode The,gclk_cal_mode,command,is,used,to,tell,the,sync,function,and,MCUF,software,that,a,calibration,is,to,be,performed., The,system,will,prompt,for,the,following,verification,when,the,command,i s,executed:, Site,,starting,GCLK,CALIBRATION,MODE.,If,this,i s,a,single,MCU,site,,the,site,will,be,down,until,calibration,is,co mplete. Are,you,sure,(y=yes,,n=no)?,y If,the,user,replies,with,anything,other,than,y,,the,command,is,aborted.,If,the,user,r eplies,y,,the,MCUF,will,begin,calibration,mode. 1. The,user,will,then,be,prompted,with,the,following:, Frequency,Counter,Connected,,Enter,y,when,ready,,or,a,to,abort,tes t,y If,the,user,replies,with,anything,other,than,y,,the,command,is,aborted,,and,the,cal ibration,mode,exited. 1. Adjust,the,OCXO,control,voltage,using,the,+/- ,and,0,to,3,keys,until,the,measured,frequency,is,exactly,8000,000000,Hz., The,values,entered,here,,change,the,frequency,by,varying,degrees.,For,example,,+0,will,i ncrease,the,output,by,a,small,amount., +1,will,increase,the,frequency,by,approximately,10,times. +2,will,increase,the,frequency,by,approximately,100,times. +3,will,increase,the,frequency,by,approximately,1000,times. The,above,values,are,not,exact,as,every,OCXO,has,a,different,gain,,this,method,gives,suffi cient,control,to,pull-in,the,frequency,within,a,short,time., 1. A,typical,sequence,of,numbers,may,look,as,follows:, Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>-3,(7.99999898) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>+3,(8.00000020) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>-0,(8.00000019 -,8.00000020) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>-2,(8.00000004) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>+2,(8.00000020) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>-1,(8.00000018) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>-2,(8.00000002 -8.00000003), Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>-1, (8.000000--) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>+0,(8.000000-) Enter,a,to,abort.,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>+0,(8.00000000) 1. Save,the,results,by,typing,s,that,is:, Enter,a,to,abort,,s,to,save,,+(0..3),to,inc,,-(0..3),to,dec,>s, CAL,OFFSET,is,23654,DAC,bits. After,calibration,,the,MCUF,applies,a,set,of,voltages,to,the,DAC,that,feeds,the,OCXO,,this,requires,the,user,to,input,the,corresponding,output,frequency.,This,is,because,the,OCXO,frequency,V,voltage,characteristic,is,not,linear,,and,by,taking,readings,across,a,range,of,DAC,voltages,,the,MCU,can,make,adjustments,for,non-linearity., 1. To,calibrate,the,OCXO,,gain,,enter,the,measured,frequency,value,from,the,counter ,after,the,value,has,settled,in,response,to,the,MMI,prompts., When,taking,frequency,measurements,,ensure,that,a,full,gate,period,elapses,from,the,time,the,new,value,is,set,to,reading,the,counter.,This,wait,may,be,up,to,seconds,depending,on,the,counter., A,typical,sequence,of,frequency,measurements,may,be,presented,as,follows:, Dac,set,to,1.0,volts,,Enter,Freq,Value,or,a,to,abort,>,7999.99853 Dac,set,to,2.0,volts,,Enter,Freq,Value,or,a,to,abort,>,7999.99915 Dac,set,to,3.0,volts,,Enter,Freq,Value,or,a,to,abort,>,7999.99969 Dac,set,to,4.0,volts,,Enter,Freq,Value,or,a,to,abort,>,8000.00020 Dac,set,to,5.0,volts,,Enter,Freq,Value,or,a,to,abort,>,8000.00070 Dac,set,to,6.0,volts,,Enter,Freq,Value,or,a,to,abort,>,8000.00122 Dac,set,to,7.0,volts,,Enter,Freq,Value,or,a,to,abort,>,8000.00176 Calibration,Gain,3.865560e-01 SYNC> 1. On,completion,the,user,should,ensure,that,the,Calibration,Gain,is,between,0,and,1. 5.,Values,other,than,this,may,indicate,a,poor,OCXO,,or,an,error,in,performing,the,p rocedure.,The,most,common,error,is,in,reading,the,counter,when,locating,the,deci mal,point,by,eye., 2. If,the,Calibration,Gain,value,is,not,in,the,range,,calibration,should,be,performed,a gain,as,a,double,check.,If,it,fails,a,second,time,with,the,same,or,similar,value,,the, OCXO,,may,be,operating,outside,of,the,Motorola,specification.,If,this,occurs,,the,M CU,is,deemed,faulty,and,should,be,replaced.,Otherwise,the,calibration,procedure,i s,complete., 附录C,,仪器、仪表矫正标准 根据日常维护的有关规定,我们对基站维护的相关仪器仪表的性能标准和使用标准作了相应的要求,在日常维护中要根据要求配置仪表并熟练掌握仪表的使用方法。 一、 仪器仪表型号要求。 类型 用途 性能要求 可选型号 信号发生载频接收校准 支持1800MHz HP系列 仪 功率要求低,驻波比检查要求BRID 功率计 发信功率调整及驻波比检查 高,支持1800MHz,选用天馈分AP-16 析仪加功率选件 MIDTRONICS 电导测试,福州福光电蓄电池电导值测试 仪 子有限公司代 理, 地阻仪 机房内外地阻值测试 GOX系列 FLUKE,PM668频率计 时钟调整 12位显示,带铷钟 5R 红外测温REYTEK系列 电路连接点温度测试 仪 建议XM2 二、 关于仪器仪表的校准要求。 所有仪表要求每年进行一次仪表校准工作,要对矫正进行横向比较,以确认校准结果。 三、 关于仪器仪表的使用情况检查。 为确保维护工作优质高效的完成,要求维护技术人员熟练掌握各仪表的使用方法,应该不定期考核各技术人员的仪表使用技能,一旦发现有不能胜任者,要暂时取消其维护资格,直到再次考核通过为止。 附录D,,除锈、防锈标准 1、 目的 根据天线普查中发现的部件生锈问题进行维护处理 2、 采用的标准 2(1(浙江省移动通信总公司杭州分公司前期工程施 ,,,,,, 工规范 2(2(摩托罗拉公司杭州基站工程(室外部分)前期 ,,,,,, 督导技术要求 3、 适用范围 适用杭州GSM基站维护 4、 走线架等固定金属物的除锈、防锈 4(1(清除表面锈斑 ,,,,, ,4(1(1(用钢刷清除表面锈层 ,,,,,, ,4(1(2(用去锈剂清洗表面锈痕 ,,,,,,, ,4(1(3(用汽油清洗前一步骤部位(有明火或其它危 ,,,,,,,,,,,,,,,,险设施处不能用此方法) ,,,,, ,4(1(4(用干净的棉布擦干 ,,,4(2(防锈,用防锈漆处理表面 ,,,,,,,,,,,,,,4(2(1(仔细地用毛刷将防锈漆均匀地涂在保护部位 ,,,,,,,,,,,,,,4(2(2(不能留有暴露在空气中的金属部分 5、 接地线的除锈、防锈 5(1(清除表面氧化层和锈斑 ,,,,, 5(1(1(先将螺钉分离开 ,,,,, 5(1(2(用打磨机将接触部分打磨去锈 ,,,,, 5(1(3(用去锈剂去锈 ,,,,,,, 5(1(4(用汽油清洗(有明火或危险使用的地方不能 ,,,,,,,,,,,,,,,,用此方法) ,,,,,,, 5(1(5(用干棉布擦干净 ,,,,,, 5(1(6(涂上导电胶 ,,,,,, 5(1(7(再安装固定 ,,,,,,, 5(1(8(表面涂银粉漆 6、 需要的工具及材料 6(1(钢刷 6(2(打磨机 6(3(防锈漆 6(4(汽油 6(5(干棉布 6(6(导电胶 6(7(银粉漆 6(8(除锈剂 7、 锈痕严重的部件则要部分更换。 8、 本建议为维护基站的技术依据之一。 附录E,,接地、避雷标准 1. 目的 1.1.提高接地避雷的质量。 ,,,1.2.,防止雷击对GSM设备的损失。 2. 适用范围 ,,,,,适用GSM基站天馈系统的维护。 3. 的标准和引用的技术 3.1.GB50057-94防雷 设计 领导形象设计圆作业设计ao工艺污水处理厂设计附属工程施工组织设计清扫机器人结构设计 规范。 ,,,3.2.低压用户电气安全技术(上海科技出版社)。 ,,,,,3.3.移动通信设台组网(人民邮电出版社)。 ,,,,,3.4.杭州G网基站工程操作规范2.0版 4. 遭雷击概率不大,但结果致命。 5. 接地系统的质量往往成为雷击事故发生的关键。 雷电侵入波是沿着低压线路或沿空金属管道 ,,,,,进入室内,室内接地必须与室外接地分开。 ,,,,,5.2.,接地体尽量用较短的引线,避免产生接触电压。 ,,,,,,,,5.2.1.长引线需加接地环。 6. 联合接地(又称三合一接地) 联合接地是指避雷针的接地装置,天馈线的接地装 置,,,,,,,,,,,,,,,,,,, ,,,,,室内接地装置可连接在一起。 ,,,,,6.2.,避雷针的接地引线是不能与天馈线的引线直接相连的。 6.3. 在全部满足下列条件下,接地连接引线可以变通,联结 ,,,,,在一起。 ,,,,,,,,6.3.1.避雷接地的地阻远小于馈线管的直流电阻。 ,,,,,,,,6.3.2.这样连接可以使接地路由最短。 6.4. GSM基站设备的接地不能与供电电源的接 ,,,,,,,,,,地连在一起。 6.5. 在楼顶的桅杆或塔的避雷地线接入楼顶建 ,,,,,筑物的接地网。 6.6. 被避雷保护物的接地引线应与避雷接地引线 ,,,,,,,,,,,,分开。接入地网时,与避雷接地的连接线之 ,,,,,,,,,,,,间的距离满足如下: ,,,,,,,,,,,,Sd?0.1he,,,,, ,,,,,,,,,,,,he是指天线的有效高度; ,,,,,,,,,,,,Sd,表示由两接地连接之间距离。 6.7. 机房屋顶若没有避雷带,机房周围最好埋设一闭合接地 ,,,,,,,,,,环,使机房的地电位均衡分布和缩短接地引线。,,,,,,,, 6.8. 埋设在地下的接地体与不接地网的其它金属构件(如水, ,,,,,,,,,,管、暖气管道、有金属的电缆之间)应保持的安全距离: ,,,,,,,,, ,S?0.3Rch,,,,m ,,,,,,,,,, ,Rch—冲击接地电阻? ,,,,,,,,,,,,,,,注:S值小于3m时取3m。 6.8.1. 如果不能保持安全距离,金属构件应与地网作可 靠连接。 ,,,,,6.9.,单独接地,可延长避雷器的使用寿命。 ,,,,,6.10.带有避雷针的桅杆上不能悬挂天线(见 ,,,,,,,,,,GB50057-94第3、5、6条)。 7. 避雷针应热镀锌或涂漆。 8. 馈线的接地必须连接到防雷电感应接地装置上。 9. 避雷针保护的区域范围: ,,,,,,避雷针高度 保护 角?,,,,,m 防雷 ,,20 ,,30 ,,45 ,,60 滚球半径,m ,? ,,2,0 ,,25 ,,* ,,* ,,* ,? ,,30 ,,35 ,,* ,,* ,,* ,? ,,45 ,,45 ,,35 ,,25 ,,* ,? ,,60 ,,55 ,,45 ,,35 ,,25 , ,,*在这些情况下要采用避雷网 10. 雷击时,接地引线在拐弯处,会产生很强的电磁推力。 11. 避雷针与(被保护天线)应保持一定空间距离,以免避雷针上落 雷时造成对天线的反击: ,,,,,,,,,,,,,,,,Sk?0.3Rch+0.1h ,,,,,,,,,,,,,,,,Rch为冲击接地电阻,h为天线的有效高度。 ,,,,,,,,,,,,,,,,空间距离小于5m时取值5m。 12. 避雷针与避雷接地引线的接触长度不短于其直径的10倍。 13. 每根桅杆接地应就近接至楼顶避雷带。 14. 落地塔时,其铁塔地网与机房地网之间,应每隔3- ,,,,,,5m相应焊接连通一次,连接点不小于两点,其他网 ,,,,,,面积应延伸到塔基四角1(5m以远的范围,网格尺 ,,,,,,寸应不大于3*3米,其周边为封闭式。 ,,15.,7/8馈线第一接地铜排位置在沿主馈线走线方向距 ,,,,桅杆1m处。 ,,16.,馈线的接地 ,,,,,,16(1(避免在拐弯处。 ,,,,,,16(2(顺走线方向。 ,,,,,,16(3(7/8馈线一般要求三点接地(最好做在垂直 ,,,,,,,,,,,,,部分),首尾两点,中间一点。如果两点间 ,,,,,,,,,,,,,超过60m,必须增加接地点;如果小于20m, ,,,,,,,,,,,,,允许两点接地;如果小于10m,允许一点接地。 ,,,,,,16(4(接地排和接地线连接处要事先清除油漆。 ,,,,,,16(5(接地线与防雷接地铜排连接处要使用铜鼻 ,,,,,,,,,,,,,子,并用螺栓固定连接,同时防氧化处理。 ,,,,,,16(6(接地线的馈线端要高于接地排端,走线朝下。 ,,,,,,16(7(接地线与馈线的连接处一定要用防水胶和防 ,,,,,,,,,,,,,水胶布密封防水处理。 ,,,,,,16(8(馈线水平走线,接地线必须有回水弯,可以 ,,,,,,,,,,,,,适当考虑美观,减少弯度。馈线垂直走线,, ,,,,,,,,,,,,,接地线可以不要回水弯。 ,,,,,,16(9(接地线不得从封洞孔内穿过。 ,,17(接地铜牌的材料建议采用紫铜。 ,,18(固定在接地铜牌上的接地线铜镙一定要有两处固定。 ,,,,,,接地铜牌与走线架接触的长度要不少于两倍接地铜 ,,,,,,排的宽度。 ,,19(接地电阻山区必须小于5Ω,平原小于1Ω。 ,,,,,,19(1(楼顶铁塔避雷和建筑物钢筋分别就近焊接 ,,20(本标准为维护天线系统的基本依据之一。 ,,21(名词解释: ,,,,,,21(1(接地装置:接地体和接地线的总合。 ,,,,,,,21(2(防雷装置:接闪器、引下线、接地装置、 ,,,,,,,,,,,,,,过电压保护器及其它连接导体的总合。 ,,,,,,,21(3(雷电感应:雷电放电时,在附近导体上产 ,,,,,,,,,,,,,,生的静电感应和电磁感应,它可能使金属部 ,,,,,,,,,,,,,,件之间产生火花。 ,,,,,,,21(4(电磁感应:由于雷电迅速变化在其周围空 ,,,,,,,,,,,,,,间产生瞬变的强电磁场,使附近导体上感 ,,,,,,,,,,,,,,应出很高的电动势。 ,,,,,,,21(5(雷电波侵入:由于雷电对架空线路或金属 ,,,,,,,,,,,,,,管道的作用,雷电波可能沿着这些管线侵 ,,,,,,,,,,,,,,入屋内,危及人身安全或损坏设备。 ,,,22(本标准的修改权属天线督导/检查质量组。, ,,,,,,,,附表: ,,,,,,,,,,,,我国主要城市雷暴日统计表 ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 地 北京 成都 昆明 贵阳 上海 南宁 湛江 广州 海口 区 名 称 雷 . 36.736.9. 62.8. 48.9. 32.2. 88.6. 95.6. 87.6. 113.8 暴 . 日 d/a 附录F,,馈线防水胶带缠绕标准 4. 目的, ,,有效地防止接头及馈线接地处进水。 4. 适用范围 4. 适用采用胶带防水办法的天馈线施工。 4. 采用的规范 ANDREW天馈线的技术标准。 MOTOROLA,,GSM天馈技术规范。 5.,接头防水 接头防水分3个大层次。 第一层次:接头紧固后用胶带将接头金属全 ,,,,,,,,部包裹一至二层。 第二层次:用烂泥胶将胶带部分紧密包裹,两边超过接头部分至少10厘米,来回两次。 ,,,5.4.,第三层次:用宽胶带紧密缠绕 ,,,,,,,,5.4.1.,缠绕来回5-7层,建议采用7,层。 ,,,,,,,,5.4.2.,胶带每边至少长出烂泥胶10,厘米。 ,,,,,,,,5.4.3.,最外层胶带必须要从下向上包裹。 6. 馈线接地防水 ,,,6.1.,馈线的接地防水分3个层次。 ,,,6.2.,第一层次:先剪几块烂泥胶。 ,,,,,,,6.2.1.,先在接地引线接馈线端顶头包裹一层均匀的烂泥胶。 ,,,,,,,6.2.2.,与上相对应的馈线处也包裹一层烂泥胶。 ,,,,,,,6.2.3.,紧压接地引线,使两处的烂泥胶融合在一起。 ,,,,,,,6.2.4.,在接地引线有金属凸处先包裹一层烂泥胶。 6.3. 第二层次:整个部位连续包裹两层烂泥胶,超出两端10厘 米。 ,,,6.4.,第三层次:用宽胶带紧密缠绕。 ,,,,,,,6.4.1.,缠绕来回5-7层,建议采用7,层。 ,,,,,,,6.4.2.,胶带每边至少长出烂泥胶10,厘米。 ,,,,,,,6.4.3.,最外层胶带必须要从下向上包裹。 7. 包裹好的防水部位不靠近尖锐金属体。 8. 使用烂泥胶、胶带不能在低于-18?以下进行。 9. 本标准为维护MOTOROLA天馈系统的依据之一。 附录G,,馈线接头制做注意事项 1. 目的 ,,,,减少馈线驻波,提高系统运行质量。 2. 采用的标准 2(1(MOTOROLA公司相关规定。 2(2(ANDREW接头制做说明。 6. ,适用范围 ,,,,适用天线维护工程师。 4. ,制做前期准备 4(1(认真阅读每个接头的制做说明。 4(2(按说明上要求准备各种工具,最好使用制做接 ,,,,,,,,,,,头的专用工具。 4(3(严格按说明要求步骤逐步检查。 6. ,要注意事项 5(1(安装接头前必须将接头部分馈线顺直约1米,, ,以保证接头与馈线导体结合紧密。 5(2(锯截馈线时必须将锯截处向下倾斜,以免锯屑 ,滑入导管内。 5(3(锯截等刀具必须保持在最佳工作状况,一般做 ,,,,,,,,,,,,,,,,,,,2-3个接头要更换刀具。 5(4(每次锯截馈线都必须清除截口处毛刺,以防损 伤接头和导致接触不良。 ,,,,,,,,,,,,5(4(1(例如: ,,,,,,,,HUNER+SUHNER-CH9100避雷器接头,内导 ,,,,,,,,管伸出截口平面6mm,外导管喇叭口与接头 接 ,,,,,,,,触须平滑、紧密,紧固时要保持接头前端不 ,,,,,,,,动,旋转后半部紧固。 , ,,5(4(2(例如: ,,,,,,,,ANDREW-L45Z接头,注意紧固时分两次。第 ,,,,,,,,一次紧固后须拧开接头将喇叭口毛刺清除 后, ,,,,,,,,放可进行最终紧固。 ,5(5(紧固工具最好用力矩扳手紧固,力矩大小每次 , ,都要满足说明上的要求。 6. 接头的防水要严格按要求进行 ,6(1(若用胶带防水,按胶带防水的步骤进行。 ,6(2(若用冷缩管,则按该产品的要求进行。 附录H,,天馈系统馈线走线标准 1. 目的 ,,,,,,提高馈线走线质量,减少馈线对天馈系统的不利因素。 2. 采用的标准 ,,,,,,HONGBO维护执行规范。 3. 适用范围 ,,,适用天线维护工程师。 4. 馈线走线原则 4(1(馈线走线必须整齐有序。 4(2(馈线走线必须简洁,尽量避免拐弯。 4(3(馈线的接地必须可靠。 4(4(馈线入室必须有回水弯。 4(5(馈线接地必须有严格的防水措施。 5. 馈线的接地 5(1(馈线的接地一般是3点接地。 5(1(1(首尾两点,中间一点。 5(1(2(如果馈线总长超过60米,必须增加接地点; ,,,,,,如果小于20米,允许两点接地;如果小于 ,,,,,,10米,允许一点接地。 5(1(3(馈线的第一接地点的位置应在沿主馈线走 ,,,,,,线方向,距桅杆或抱杆1米处,最后接地 点的位置在馈线入室前端的走线架上 5(1(4(馈线接地点不要选在馈线弯曲变形压力较 ,,,,,,大的地方,例如弯曲点不应选为接地点。 5(1(5(接地线尽可能不弯曲,顺馈线走线。 5(1(6(接地线的馈线端要高于接地排端。 5(1(7(接地线与接地排的接触要有两点。 5(1(8(接地线不得从封洞孔内穿过。 5(1(9(接地处的接地电阻必须满足要求。 5(2(馈线接地的防水 5(2(1(馈线接地与馈线连接处一定要用防水胶和 防水胶布密封防水或用其他可靠的防水 5(2(2(馈线水平走线,接地线要有回水弯;馈线 ,,,,,,垂直走线,可以不要回水弯。 6. 馈线的固定 6(1(馈线必须有连续固定。 6(1(1(馈线要用专用馈线卡固定。 6(1(2(两固定点之间的距离不大于0.8米 6(1(3(馈线的馈线卡必须固定在牢固、合格的走 线架上。 6(1(4(馈线的馈线卡必须整齐,同一组馈线卡尽 ,,,,,,量一致;不同组的馈线卡的间距应该一致。 7. 走线的要求 7(1(馈线走线需要弯曲,其弯曲半径应满足下面要求: 7(1(1(馈线最小曲率半径 ,,,,,,, ,,最小曲率半,,最小曲率 馈线种径 半径 类 ,,(重复弯,,(单次弯 曲) 曲) ,,1/2" ,,,,200mm ,,,,100mm ,,7/8" ,,,,360mm ,,,,120mm ,15/8" ,,,,800mm ,,,,400mm 7(2(馈线拐弯,其弯曲角度不小于90度,最好大于120度。7(3(馈线拐弯后,要立即固定。 7(4(馈线拐弯要舒缓、流畅。 7(5(馈线施工吊线时,必须有专用施工工具吊线。 7(6(馈线施工时不能直接在地面上拖动。 7(7(馈线应防止被金属或坚硬物碰撞,以免发生变 ,,,,,,,,,,,形或损坏表面橡胶。 8. 馈线的回水弯 8(1(馈线入室必须有回水弯。 8(1(1(回水弯的底部与入室端口的水平高度要低 ,,,,,,于10厘米。 8(1(2(回水弯的弧度要流畅。 8(2(同组馈线的回水弯要互相固定。 8(3(馈线入室必须要有密封圈防水。 8(4(馈线入室后必须有较好的固定。 9. 馈线首尾必须悬挂与天线对应的天线标牌。 10. 本标准为维护MOTOROLA,GSM天馈系统依据之一。 附录I,,天线维护质量标准 1. 目的 规范天线维护系统运行质量。 2. 适用范围 天线维护工程师。 3. 采用的标准 HONGBO维护执行规范。 4. 施工必须有设计图纸 5. 方位角: 5(1(正北为零度,顺时针方向为正,不取负值,用 ,,,,,,,,,,,指南针测量。 5(2(根据实际情况划为3个扇区,根据当地的频点 ,规划设计制订。 6. 附仰角: 6(1(电调俯角:Deltec天线专有参数,用专用工具 ,测量,精确到小数后1位。(对于未装控制线 ,的老站用螺杆进行调试) 6(2(机械俯角:指天线的轴向与竖直方向之间的夹角。 6(3(合计俯角:电调俯角(包括内置角度)与机械俯 ,,,,,,,,,,,角之和,也就是天线的俯仰角。 6(4(天线安装俯角在天线网络规划指定的角度内,, ,,,,,,精度为?0.5度;ALLGON天线按要求自然调 ,整到3度。 7. 天线的最小隔离度:与该天线垂直方向最近的天线的距离。 7(1(测量时,用卷尺或测绳。 7(2(特殊情况可以用目测,精确到米,但必须注 ,明是“目测”。 7(3(天线间的最小垂直距离为1.1米。 8. 天线水平隔离度:与该天线水平方向最近的天线的距离。 8(1(测量时,用卷尺或测绳。 8(2(特殊情况,可以用目测,精确到米,但必须注 ,明是“目测”。 8(3(定向天线间的最小水平距离为3米,全向天线 ,间的最小水平距离为4米。 8(4(分集接收天线水平间距取决于天线高度,近似, ,公式为:d?0.11*,he ,,,,,,d是指天线之间的距离 ,,,,,,he是指天线的有效高度 9. 天线安装相对高度 楼高与铁塔或平台高度总和,若有相同小区的天线处 于不同高度要在报告中注明。 9(1(天线安装在天线网络规划指定高度内,准确度 ,,,,,,,,,,,为?2米。 10. 天线组装必须按其说明书严格执行。 11. 天线安装牢固:可用手摇晃测试其安装强度。对 附件用扳手逐一校准,完成后再用手摇晃无松动方可。 12. 天线是否有明显弯曲: ,,,检测天线平面是否有变形,督导时注意天线调整俯角时, ,,,必须先将上、下两组紧固螺钉旋松,尤其应当注意ALLGON ,,,天线。用水平仪取天线上、中、下三站测量确认。 13. 天线接地: Deltec天线特有,用于天线调整控制线的接地。 14. 天线的避雷: 应严格按天馈系统的避雷标准执行。 15. 天线极性与馈线标号的对应关系。 ,,,15(1(将一个扇区1、3号馈线接于垂直极化或+45 ,,极化端口。 15(2(将2、4号馈线接于水平极化或-45极化端口。 15(3(天线的挂牌标志对应关系如下: ,,a—b—c ,,其中:a指扇区;b指天线顺序;c指天线 ,,的极化方向。这些都与相应的馈线对应。 16. 电调天线的特殊工艺要求 16(1(控制线必须安装避雷器,每个避雷器必须 ,,有独立的接地,用绿色(线径2mm)的接地线。 16(2(避雷器的安装尽量靠近窗口,接地引线尽 ,,可能短。 16(3(避雷器的接地引线要每0.5米有一个扎带固定。 17. 天线的位置要求 17(1(天线要求离开导体距离大于0.6米,全向 ,,天线的距离要大一些。 17(2(靠近全向天线的圆柱形导体最好用微波吸 ,,收材料包裹。 18. 天线接头的防水 天线接头与尾线接头要接触紧密,防水用防水胶带包裹, 包裹方法按标准执行。 19. 天线的性能要求 19(1(安装的天线要有合格证。 19(2(安装的天线要能提供完整的参数。 19(2(1(驻波:天线输入端口的驻波。 19(2(2(方向图:同一型号的方向图。 19(2(3(要有明确的极化特性。 19(2(4(要提供频带响应,即天线的工作频率带宽口。 19(3(安装测试其驻波是否满足要求定向天线驻 ,,波应小于1.3,全向天线驻波应小于1.4。 附录J,天线尾线的质量标准 1. 目的 规范对尾线维护。 2.,适用范围: ,所有基站天线尾线维护。 3. 采用的规范标准: 3(1(采用杭州GSM网基础工程操作规范。 3(2(采用浙江省GSM基础施工规范。 3(3(Andrew和MITSUBISHI馈线技术要求。 4. 尾线的物理特性: 4(1(尾线的阻抗50Ω。 4(2(尾线的长度建议不大于2m,塔上不大于3m。 4(3(尾线必须是专用的室外线。 4(4(尾线的最小弯曲半径为0.2m。 5. 尾线的防水: ,尾线短,而且有两处接头,因此尾线防水至关重要。 ,5(1(尾线的防水至少有三层。 5(2(尾线防水胶带最外层必须是宽胶带。 5(3(尾线防水胶带的绕法按标准缠绕。 6. 尾线的固定: 6(1(尾线至少有两点固定。 ,6(2(尾线注意绑扎与桅杆或悬臂固定绑扎: ,,,,,,,,,,,a:3m桅杆用扎带绑扎;b:6m桅杆如有固定 ,,,角铁,则用馈线夹固定;6m桅杆如无固定 ,,,角铁,则用桅杆卡固定。 6(3(尾线固定建议不要直接与铁体相接触(防止 ,,,桅杆或角铁上的毛刺损坏尾线)。 6(4(尾线要留有一点的多余尾线,以方便维护。 6(5(尾线在与天线底部3个工作波长内距离要整 ,,,,,,,齐,与天线底部呈垂直状态。 ,,,,,,,6(5(1(全向天线犹为重要。 7. 尾线的驻波: ,尾线与馈线处的接头驻波应小于1.3。 8. 本标准为维护天馈系统的基本依据。 附录K,桅杆的质量标准 1.目的: ,,明确桅杆的施工质量要求。 2. 适用范围: ,,适用楼顶桅杆的建设。 3. 采用的标准: ,,杭州G网基站工程操作规范2.0。 4. 桅杆必须有牢固的接地,直接接入地网或直接就近接入接地 环,接地点不小于两处。 5. 高度超过3m的必须有专门加固拉线或三角架。 5(1(加固拉线或三角架必须与天线距离有3-5个工作波长。 ,,,,,5(2(天线正前方不能有拉线或角架。 ,,,,,5(3(桅杆底部要用水泥绕铸。 6. 高度超过3m的桅杆必须有维护用的爬梯。 7. 桅杆垂直度小于1/1500m,扭曲度小于1/1500m。 8. 镀锌层大件,86微米,小件,65微米。电镀应采用热镀。 9. 表面用防锈漆覆盖。 10. 桅杆必须坚固,并有牢固可靠的固定。桅杆上每米应有一定 ,,,,,馈线的角铁。 11. 桅杆顶部若有避雷针,则应直接就近接入地网。 12. 高于3-6米的桅杆,底于3米部分建议用80mm钢管,高于3 米部分用50mm钢管。钢管的管壁厚度,应满足相应的国家标 准。 13(,标准为天馈维护质量依据之一。 ,,, ,,, 附录L,,走线架质量标准 ,,1.,目的: 延长走线架使用寿命,确保走线架的固定作用。 2. 适用范围: ,,此标准为合理条件下的走线架,不同的场合经用户 ,,工程师的同意可做变通。 3. 相关规范: ,,天馈线施工技术要求,ANDREW和MITSUBISHI ,,馈线技术要求。 4. 走线架的宽度要求: 4(1(走线架的宽度: ,,,,,,,,a:仅G网:垂直60cm ,,,,,,,,水平40cm ,,,,,,,,b:共站:,,垂直100cm ,水平80cm ,,4(2(从桅杆到主走架的部分走线架宽度 ,,,,,,,,a:仅G网30cm; ,,,,,,,,b:共站40cm。 5. 走线架的支撑高度: 5(1(走线架在水平方向延伸时,架高必须?30cm。 5(2(走线架在有斜坡或垂直下行时,其支撑高度 ,,,,,,,,?20cm。 ,,5(3(走线架支撑间距不大于2m,垂直走线间距 ,,,,,,,,不大于1.6m。 ,,,,,5(4(垂直走线架应保证每米承受力不小于300kg。 ,, 5(5(垂直走线架离进线窗不小于50cm。如图所示:, 6.,从天线尾线始到进入机房内后,整个馈线必须要有 ,,,连续的走线架。 7.,走线架横档: 7(1(走线架水平或斜坡走向时,横档间距?80cm。 7(2(走线架横档宽度不小于4cm,厚度不低于4mm。 7(3(走线架横档若是焊接,则焊点必须有足够宽 ,,,,,,度的接触。 7(4(走线架若用镙钉固定,则镙钉直径不小于 ,,,,,,8mm;固定时,必须有垫片及弹簧垫片。 ,,,,,,,,,,,,,,7(5.,走线架在拐弯时,建议距内拐弯0.3m和0.6m ,,,,,,处两根带孔的用镙钉固定的横档备用(在正 ,,,,,,常的横档之外)。 ,,,7(6(走线架在入室前至少要留有一处活动横档。 8.,走线架接地: ,,,走线架必须接入地网中,最好有两点以上接地。 9. 走线架入室: ,,,9(1(走线架在入室时,要有低于馈线窗1.5-2m,, ,,,的施工爬梯。 ,,,9(2(60厘米宽的走线可不需另外的施工爬梯。 ,,,9(3(走线架走向要对准馈线窗。 10.走线架架设时,尽量避免连续拐弯,拐点数量尽量在 3点左右。,,,,,,,,,,,,,,,,,,,,,, 10(1走线架拐弯时尽可能角度较大(?100度)。 11.走线架的材料应用标准4*4(cm)或5*5(cm)角钢。 12.防水处理: ,,,,,12(1(整个走线架的材料在施工前必须进行防锈 ,,,,,,,,,,,,处理(热镀、镀锌)。 ,,,,,12(2(所有固定用的零件,必须表面镀锌(热镀), ,,,,,,,,,,,,或其它可靠的防锈处理。 ,,,,,12(3(走线架焊接的地方必须有完好的防锈。 ,,,,,12(4(尽量避免对已进行过防锈处理过的走线架 ,,,,,,,,,,,,进行破坏性处理。 ,,,,,12(5(镀锌层大件大于86微米,小件大于65微米。 13.走线架施工完后,建议再用防锈漆处理。 14.走线架设计时,要考虑到走线的方便,尽量减少使 ,,,馈线拐弯的次数。 15.走线架设计时要考虑到整齐、简洁。 16.接地铜排。 ,,,,,16(1(铜排宽?3cm。 ,,,,,16(2(铜排厚度?3mm。 ,,,,,16(3(长度应与走线架同宽。 ,,,,,,,,,,,,规格为:a:共站1000cm、80cm。 ,,,,,,,,,,,,b:仅G网60cm、40cm、30cm。 ,,,,,16(4(銅排的接避雷线孔各数为:, ,,,,,,,,,,,,100,cm,8孔; ,,,,,,,,,,,,80,cm,8孔; ,,,,,,,,,,,,60,cm,4孔; ,,,,,,,,,,,,40,cm,4孔; ,,,,,,,,,,,,30,cm,2孔。 ,,,,,16(5(与走线架接触点的长度必须不小于其宽度的2倍。 17.本标准为维护天馈系统依据之一。
本文档为【宝典gsm基站子系统】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_296227
暂无简介~
格式:doc
大小:186KB
软件:Word
页数:0
分类:互联网
上传时间:2017-12-21
浏览量:22