Sheet1
Test items MIL-STD-810G Confirm conditions Sample
Dimension MIL-STD-810G军标测试试验要求
High Temperature 501.5
Procedure I - Storage. Procedure I - Storage.
Seven 24-hour cycles,Total 168hours.
Humidity no need control
Basic hot--Table 501.5-II. Induced Conditions 126mm*77.26mm*9.8mm 1.只要求做高温储存,7个24-hours循环
2.温度为30~63℃循环温度,24 hours 一个循环,详见Table 501.5-II. Induced Conditions
501.5
Procedure II - Operation. Procedure II - Operation
Three 24-hour cycles,Total 72hours
Humidity no need control
Basic hot--Table 501.5-II. Ambient Air Conditions 1.只要求做高温工作,3个24-hours循环
2.温度为30~43℃循环,24 hours 一个循环,详见Table 501.5-II. Ambient Air Conditions
Low Temperature 502.5
Procedure I - Storage. Procedure I - Storage.
a.Nonhazardous or non-safety-related (non-life-support type) materiel:4hours
Basic cold (C1)-Table 502.5-I. Induced Environment 1.只要求做低温存储,4h
2.恒定温度-33℃
502.5
Procedure II - Operation. Procedure II - Operation.
a.Nonhazardous or non-safety-related (non-life-support type) materiel:4hours
Basic cold (C1)-Table 502.5-I. Ambient Air 1.只要求做低温工作,4h
2.恒定温度-21℃
Temperature Shock 503.5
Procedure I-B Procedure I-B Single cycle shock from constant extreme temperature.
Figure 503.5-2.-- transfer rate 1minute max.
1cycle ,30min for Low and 30min for High
Low temperature: -33 ℃
High temperature:63℃ 1.Thermal shock 曲线如下:
Rain 506.5
Procedure I - Rain and Blowing Rain. Procedure I - Rain and Blowing Rain.
1.Handset temperature 10°C Higher than water
2.Exposure duration:30 minutes. 试验需要满足的条件及参数如下:
1.recommend a minimum rate of rainfall rate:1.7 mm/min
2.Handset temperature 10°C Higher than water
3.droplets diameter from 0.5mm to 4.5mm
4.the drops approach terminal velocity :about 9m/s
5.horizontal wind velocities equal to and exceeding 18 m/s.
6.Exposure duration:30 minutes.
7.Test Facility:Figure 506.5-1
Humidity 507.5
Procedure II Aggravated Cycle Procedure II Aggravated Cycle
30℃~60℃ 95%RH,10days
Figure 507.5-7 and Table 507.5-IX 1.温度范围30℃~60℃ ,相对湿度95±4%
2.24-hour 一个cycle,曲线如下:
Sand and Dust 510.5
Procedure I - Blowing Dust Procedure I - Blowing Dust.(< 150 μm).
Dust composition.:140 mesh Silica Flour(100 percent less than 150μm, 50 percent of 20 ±5 μm.)
6 hours at standard ambient temperature, and an additional 6 hours at the high temperature(Basic hot 43℃)
same as IP6X 1.Relative humidity (RH) :at 30 percent or less
Air velocity:1.5 ±1 m/s to 8.9 ± 1.3 m/s
Dust concentrations.:10.6 ±7 g/m3
Dust composition:140 mesh Silica Flour(100 percent less than 150μm, 50 percent of 20 ±5 μm.)
6 hours at standard ambient temperature(23℃), and 6 hours at the high storage or operating temperature.(43℃)
Immersion 512.5
Procedure I -Immersion Procedure I -Immersion
Depth of complete immersion:1±0.1m(measured from the uppermost surface of the test item to the surface of the water)
Duration of immersion:30 minute
10°C above the water temperature(normal water temperature,Standard Ambient) 样品温度需高于水温10℃
Vibration 514.6
Procedure I - General vibration.
Category 4 - Truck/Trailer - Secured Cargo. Procedure I - General vibration.
Category 4 - Truck/Trailer - Secured Cargo.
1. Truck transportation over US highways
---refer to Figure 514.6C-1 and Table 514.6C-II.
2.Exposure durations. 60 minutes per axis 军标要求及实验参数
1.使用
标准
excel标准偏差excel标准偏差函数exl标准差函数国标检验抽样标准表免费下载红头文件格式标准下载
实验室振动激励器(振动台)、滑台、夹具
2.试验参数:10-500Hz, 1.04Grms vertical, 0.204Grms transverse, and 0.704 longitudinal axis, 60min per axis
3.具体振动曲线及参数设置参见Figure 514.6C-1 and Table 514.6C-II.
514.6
Procedure I - General vibration.
Category 8 - Aircraft-propeller. Procedure I - General vibration.
Category 8 - Aircraft - propeller.
Exposure durations: one hour per axis 军标要求及实验参数
1.使用标准实验室振动激励器(振动台)、滑台、夹具
2.具体振动曲线及参数设置参见:Figure 514.6C-7 and Table 514.6C-IX.
Shock 516.6
Procedure III - Fragility. Procedure III - Fragility.
1.Trapezoidal shock pulse
2.Drop height (h):76cm
3.maximum acceleration level (Am):15g's.
4.one shock per axis
Please refer to Figure 516.6-11 机械冲击
Sheet2
Sheet3