软横跨支柱容量验算
1 各悬挂点负载
(1)解除悬挂的单位自重
站线:承力索GJ—70,Tcmax=1500kg; 接触线TCG—100,Tjm=1000kg。 正线:承力索GJ—70,Tjm=1500kg; 接触线TCG—100,Tjm=1000kg。
g,0.89kg/mg,0.615kg/mg,0.05kg/m,, jcd
q,q,q,q,1.555kg/m正线与站线相等: 0jcd
(2)软横跨承担的纵向悬挂的垂直负载
G,G,G,G,G,G,G,1.555*65,101.1kg 正线与站线相等:53,,468(3)各节点重量
判定节点类型,从A到B分别为:1,10,5,5,10,5,5,10,2
1'' G,G,J,*(5*3*3),11.3,22.5,33.8kg58102
'''G,G,G,J,7.29kg 3465
'G,0.5J,J,0.5*65.6,7.29,40.09kg ,85
'G,J,0.5J,11.3,32.8,44.1kg ,108
(4)横向承力索,上、下部定位索分摊到各悬挂点的垂直负载
5,75,7 P,(g,2*g)*,(0.615,2*0.411)*,8.622kg5hd22
5,5.35,5.3 P,(g,2*g)*,(0.615,2*0.411)*,7.4kg3hd22P,P,7.4kg ,3
5,55,5P,P,P,(g,2*g)*,(0.615,2*0.411)*,7.185kg ,46hd22
5,3.35,3.3 P,(g,2*g)*,(0.615,2*0.411)*,5.96kg8hd22(5)各悬挂点总垂直负载
'Q,G,G,P,2*101.1,33.8,8.622,244.82kg 5555
'Q,G,G,P,101.1,7.29,7.4,115.79g 3333
'Q,G,G,P,101.1,40.09,7.4,148.59kg ,,,,
'Q,G,G,P,2*101.1,44.1,7.185,253.485kg ,,,,
'Q,G,G,P,101.1,7.29,7.185,115.58kg 4444
'Q,G,G,P,101.1,7.29,7.185,115.58kg 6666
'Q,G,G,P,2*101.1,33.8,5.96,241.96kg 8888
2确定水平张力T
(1) 由,M,0得: B
*,*,*,*,*,*,*QXQXQXQXQXQXQX5533,,,,446688,FA 5,5,5,5,5,5.3
244.82*7,115.79*12,148.59*17.3,253.485*22.3,115.58*27.3,115.58*32.3,241.96*37.3,30.3
,899.02kg
F,,Q,F,244.82,115.79,148.59,253.485,115.58,115.58,241.96,899.02,336.79kgBiA
F,Q,Q,0QF,Q,0(2)判定最低点:,,故最低点为节点。 B536B5
f,H,H,C,S,100,15,8.91,0.8,0.94,0.1,4.25m(3) maxsmin1
对最低点取力矩:
M,F*(7,5),Q*7,336.79*12,244.82*7,2327.74kg,m maxB5
M2327.74maxT,,,547.7kg故水平张力 f4.25max
T,T3求上、下部定位索的张力 XS(1) 线索风负载:
,6,62P,0.615,10K,,,d,l,0.615,10,1.25,0.85,25,11,65,29.185kg/m c
11.8,12.8,6,62P,0.615,10K,,,d,l,0.615,10,1.25,0.85,25,(),65,32.63kg/mj2
(2)接触线“之”字力:
a0.4P,4T,,4*1000*,24.615kg j之l65
,,P,T,sin6,1500sin6,156.79kg(3)下锚力: CMC
,,P,T,sin6,1000sin6,104.53kg JMJ
T,100,7*29.185,156.79,461.09kg S
T,100,7*32.63,7*24.615,104.53,605.25kg X
200(4)支柱的风负载,预选 G15
200由支柱类型可知,支柱顺线路方向顶宽c=0.4m,支柱顺线路方向底宽d=0.8m,故支G15
2柱受风面积S为:S=1/2*(0.4+0.8)*15=9m
2,32,3P,0.615KFV,10,0.615*1.4*9*25*10,484.31kg支柱受风力: 0
MmaxT,,2327.74/5.525,421.31kg hFmax
故作用于支柱上的总弯矩为:
1,,,, MTHTHTHPHRhSSXX风2
,421.31*14.935,461.09*8.91,605.25*7.35,0.5*484.31*15
,18.481(t,m)
200G故选择型的钢柱满足要求。 15