首页 TYCO端子压着标准

TYCO端子压着标准

举报
开通vip

TYCO端子压着标准 GLOBAL APPLICATION TOOLING DIVISION Quality Guidelines Tyco Electronics Crimp Technology All figures are schematic depictions. In every case, relevant product and application specification take precedence. 1309130–1.5M–TP © 2002 Tyco Electronics AMP Gm...

TYCO端子压着标准
GLOBAL APPLICATION TOOLING DIVISION Quality Guidelines Tyco Electronics Crimp Technology All figures are schematic depictions. In every case, relevant product and application specification take precedence. 1309130–1.5M–TP © 2002 Tyco Electronics AMP GmbH Correct Incorrect F- CR IM P For double wire applications with different size wires always place wire with smallest outer diameter in the bottom. Insulation is securely held Crimp barrel closed Bellmouth must always be present Locking lances and terminal body not deformed Terminal bend Conductor Present Insulation Present Bellmouth Permissible Cut off tabs present Crimp barrel is closed, legs support each other Crimp barrel does not close. Legs too close to bottom of crimp. Insufficient deformation of strands, showing voids. Insufficient deformation, showing voids Flash at under side of crimp, due to over crimping Terminal feed incorrectly adjusted Anvil and crimper not aligned or worn Wire size to large Wire size to small Wire crimp without conductor Insulation must be securely held after bend test Crimp height too loose Crimp height too tight Asymmetric crimp Unacceptable formation excessive flash and/or cracks Sufficient gap between legs and bottom of crimp All strands are equally distributed and deformed Insulation is pierced and could damage conductor Insulation material is pierced Insulation is over crimped Insulation legs are not closed Insulation is not securely held Legs do not overlap Insulation is not securely held Insulation is securely held Legs overlap Insulation securely held Legs must pass each other OV ER LA P CR IM P Correct Insulation Diameter, Applicator and Terminal. Correct selection of wire, terminal and applicator Digital crimp height micrometer (0.001mm increments) according to DIN ISO 9001 part number 547203-1 Incorrect terminal/wire selection Incorrect crimp height adjustment Incorrect applicator adjustment Crimp height measurement Crimp heights and tolerances W RA P OV ER CR IM P Test Training Conductor Brush protruding into terminal body Bellmouth on wrong end Insulation inside the wire crimp Crimp height too tight Terminal twisted Terminal damaged Cut off tab deformed Cut off tab too long Crimp barrel distorted WIRE CRIMP WIRE CRIMP WIRE CRIMP INSULATION CRIMP INSULATION CRIMP INSULATION CRIMP 30° 30 ° Please contact our service hotline for current training schedule. Tel.: ++44 12 37 42 86 73 Fax: ++44 12 37 42 86 89 For crimp height tolerances for any given contact, please refer to the relevant application specification. Examples: Contact P/N Wire Range Tolerance Application Spec. MQS 962885 0,20 - 0,50 mm2 ± 0,03 mm 114-18025 962886 JPT 927775 0,50 - 1,00 mm2 ± 0,05 mm 114-18050 JPT 927773 1,50 - 2,50 mm2 ± 0,05 mm 114-18050
本文档为【TYCO端子压着标准】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_300563
暂无简介~
格式:pdf
大小:592KB
软件:PDF阅读器
页数:1
分类:生产制造
上传时间:2011-02-22
浏览量:131