LOOP DETECTOR环形线圈检测器LOOP DETECTOR环形线圈检测器 Vehicles Detector System (KDS-2001) 1. Produced in China 2. Introduction: when vehicle coming to gate, It can use underground with loop coil of change of frequency It also use one by one (1 loop coil into ground easily detected by...

LOOP DETECTOR环形线圈检测器
LOOP DETECTOR环形线圈检测器 Vehicles Detector System (KDS-2001) 1. Produced in China 2. Introduction: when vehicle coming to gate, It can use underground with loop coil of change of frequency It also use one by one (1 loop coil into ground easily detected by 1 loop detector. When detector completely set up once time. It is not affected by any change of temperature, humidity,and no circumstance.It has installed AUTOMATIC FREQUENCY CONTROL) It can easily control by automatic frequency itself 3. Specification 1)Supply power : AC 110V/220V, ?10%, 50/60HZ ,DC 12V/24V 2)Consuming power : normal 1.0W, operation 3.6W 3)Operating temperature : -20 -?50C, humidity 30%-85% 4)Size : 105mm(H) × 75mm(W) ×41mm(D) 5)Quality of material : aluminum, aluminum 6)Weight : 282g 4. Function 1) detection method : Pass detection mode( Frequency change mode) 2) detection range : All of vehicle 3) sensing range : LOOP COIL width over vehicle space distance 4) detection speed : 0Km-180Km/h 5) sensitivity: High sensitivity - Low sensitivity ( 8 Level) 6) Alignment : Automatic alignment system 7) timer function : 0-14 Second control the time by option 8) Reset function : Reset bottom when error occur (Automatic:30 SEC, Manual:Option) 9) Output singnal : No power relay ( short or long point of contact) 1 5. Exterior DIP S/W setting up 1) DIP S/W 1 : Auto Reset and sensitivity When Normal control have error, It can be automatically reset after 30 second 2) DIP S/W 2 : Frequency sensitivity control When they use 2 detector which can be adjust different types of method as High( 64) Low( 59) They are both avoid interference each other DIP S/W Function ON OFF 1 Auto Reset 30 Second OFF 2 Frequency LOW HIGH 3) DIP S/W 3,4,5 : sensor sensitivity control 1-8 level available for sensitivity control and recommend Setting 5 for general level Sensitivity DIP S/W 3 No 4 No 5 No 1 OFF OFF OFF 2 ON OFF OFF 3 OFF ON OFF 4 ON ON OFF 5 OFF OFF ON 6 ON OFF ON 7 OFF ON ON 8 ON ON 0N 4) DIP S/W 6,7,8 : time Setting When light signal use, it can be possible to setting ring sound 2 Time DIP S/W 6No 7No 8No 0 second OFF OFF OFF 2 second ON OFF OFF 4 second OFF ON OFF 6 second ON ON OFF 8 second OFF OFF ON 10second ON OFF ON 12second OFF ON ON 14second ON ON ON 6. Interial DIP S/W Setting up Chart -1 No Function ON OFF 1 2second Delay When vehicle sensing after 2second, When vehicle sensing Relay will be on positon Relay will be on right away 2 IN/OUT IN: Relay ON OUT: Relay ON setting 3 Clear time 30 Second Clear 8 second Clear / Counter function 4 None Not use 5 DIP S/W 1,2 ON : 2Ea will be use at the same time of Long Puls 3 Inside DIP S/W Opeation After2 Sec Short-Pulse Short-Pulse(2second and Process Play ) Loop sensing After 0.5 Sec Inside DIP S/W 1No ON action – chart-1(1) Short-Pulse Short-Pulse(Play) Process Loop Sensing After 0.5 Sec Inside DIP S/W 1No OFF Play - chart-1(1) OUT IN OUT IN Process ON(Entry) OFF(Exit) Inside DIP S/W 2No Play - Chart-1(2) Long-Pulse Long-Pulse Process Relay 1 Relay 2 Inside DIP S/W 1, 2No ON Plsy chart-1(5) - * simultaneously point of contact signal 7. CONNECTOR chart -2 4 connectorNo function 7 1 1, 7 Loop Coil 8 2 2, 8 Sin, GND 9 3 10 4 3, 9 Short Puls, Com 11 5 4, 10 Lnc, Snc 12 6 5, 11 Long Puls, Com 6, 12 AC220V IN Direction recognitioin 30 Second ON Loop 1 Loop 2 IN 8 Second OFF OUT Connector 3,9 connector 2,8 Detector 1 Detector2 connector 2,8 connector 3,9 Inside DIP S/W 3No chart-1(3) Time Clear connector connection chart-2 After step on 1loop coil sensing and then go to Loop 2, signal counter will be operated (inside Dip S/W 30 Sec.On occur /off occur 8 Sec).After pass time of Loop 2, Signal counter will be automatically cleared, After step on loop 2 it can come to single singal inside Dip S/W 3 Number counter reduction time setting ->sensor and input port can be possibly to count on maximun 3 times and after 4 times will be played relay motion(When Dip S/W 3 No off: per 8 second will be reduct 1 times. Dip S/W 3 number On : per 30 second will be reduct 1 times) 5
本文档为【LOOP DETECTOR环形线圈检测器】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_180829
暂无简介~
格式:doc
大小:105KB
软件:Word
页数:8
分类:工学
上传时间:2017-12-05
浏览量:21