首页 监理手册

监理手册

举报
开通vip

监理手册全套监理手册全套监理手册PAGEPAGE45全套监理手册PAGE监理手册陵县永安工程建设监理优异文库目录一动工前的准备工作二地基基础工程动工2.1土方开挖·································································012.2基土钎探·································································012.3验槽············...

监理手册
全套监理手册全套监理手册PAGEPAGE45全套监理手册PAGE监理手册陵县永安工程建设监理优异文库目录一动工前的准备工作二地基基础工程动工2.1土方开挖·································································012.2基土钎探·································································012.3验槽·····································································022.4地基办理·································································022.5垫层·····································································032.6钢筋工程·································································042.7模板工程··································································072.8混凝土基础································································082.9砖基础····································································112.10防潮层···································································112.11回填土···································································12三主体工程3.1砌砖工程·································································133.2混凝土多孔砖工程··························································133.3钢筋工程·································································143.4模板工程·································································143.5砼工程···································································153.6预置空心楼板工程·························································16四装饰装饰4.1抹灰工程·································································184.2地暖工程·································································194.3外墙保温工程·····························································204.4室内防水工程······························································224.5铝塑门窗安装······························································234.6面砖镶贴··································································244.7内、外墙涂料粉刷工程·····················································25五屋面工程安装篇一基础电气工程·····························································27二基础给排水工程···························································27三主体电气工程·····························································27四主体给排水工程···························································28五装饰电气工程·····························································28六装饰给排水工程···························································29其余········································································32建筑工程资料检验取样 标准 excel标准偏差excel标准偏差函数exl标准差函数国标检验抽样标准表免费下载红头文件格式标准下载 ····················································33建筑工程动工质量查收一致标准················································37招待下载2优异文库标准标准基本用词说明························································41建筑工程资料管理基本要求····················································42一、动工前的准备工作一、动工前的准备工作:编制监理规划、监理细则、旁站规划、安全监理规划、安全监理细则、安全旁站规划。审察动工单位动工组织 设计 领导形象设计圆作业设计ao工艺污水处理厂设计附属工程施工组织设计清扫机器人结构设计 、技术交底、工程管理人员上岗证。应采集的资料:动工赞同证;规划赞同证;动工单位资质、安全生产赞同证、现场管理人员名单。熟习高程控制点及轴线控制桩。熟习图纸及现场状况.主持召开第一次监理睬议,需鲜亮内容:监理人员职责及分工;监理管理工作的一些要乞降规定;例会召开的时间、地址、主要参加人员。二、地基基础工程动工1.土方开挖1.正惯例定1.1土方开挖时,应防守四周已有建筑物或修建物、门路、管线等发生下沉和变形。应与设计单位也许建设单位磋商采纳保护措施,并在动工中进行沉降和位移观察。当土方工程挖方较深时,应采纳措施,防守基坑底部土的隆起并防止伤害周边状况。1.2土方不该群集在基坑边沿。资料堆放应距坑沿1米以上的间隔,堆土高度不超出1.5米。2.监理重点2.1基槽开挖前,楼体放线一定经规划部门查收合格。2.2禁止超挖,假如超挖,超深部分的办理应由设计单位判定规划,动工单位不得私自填埋。2.3冬天开挖后,如基础垫层不可以紧跟动工,应将基坑〔槽〕覆盖,防守基土冻结。2.4当开挖深度超出3米或虽开挖深度没超出3米但地质条件和周边状况错杂的,应采纳基坑支护措施。2.5采纳机械动工时,只好挖至设计高程以上30cm,以下用人工挖至设计高程。2.基土钎探1.正惯例定1.1为探明地基在必定深度内能否存在坟坑、古井、古河流、人防工程等异常和土质分部不均状况,对地基进行钎探。1.2钎眼间隔当设计没有规定,且满堂开挖时,此间隔不大于1.5米,呈梅花型部署,钎探深度不得小于1.8米。招待下载3优异文库1.3钎眼部署应和钎眼部署图符合。钎探数据应真切有效,填写清楚,钎眼表记应清楚,便于查找。钎点地点用白灰方格线控制,探孔离槽边0.2米左右。2.监理重点2.1检验钎眼深度。用2米长钢筋,检验实质钎探深度。2.2灌砂。验完槽后,应即时用细砂灌钎眼。3.验槽验槽由建设单位组织,设计、勘探、动工、监理、质检站参加。验槽建议以勘探和设计为主。验槽建议一定产生书面文件,并有各责任主体署名。没有书面验槽文件,不得对地基进行办理。4.地基办理灰土地基.1.1正惯例定:灰土应搀合平匀,颜色一致,并保持必定的湿度,加水量宜为搀合料总重量的16%。灰土分段动工时,上下两层灰土的接槎间隔不得小于500mm。当灰土垫层标高不一样时,应作成阶梯形。接槎时应笔挺切齐。接缝不要留在荷载较大的部位。灰土最上一层完成后,应拉线或用靠尺检验标高和平坦度,超高处用铁锹铲平;低洼处应即时补打灰土。宜优先采纳黏土、粉质黏土或粉土,不得含有有机杂物,使用前应先过筛,其粒径不大于15mm。石灰应用块灰,使用前应富裕熟化过筛,不得含有粒径大于5mm的生石灰块,也不得含有过多的水分。当灰土厚度小于等于20cm时,可采纳小型机械搅拌〔30或50拖拉机〕;当灰土厚度大于20cm小于等于30cm时,需用大型灰土拌和机搅拌,也可用小型机械分两层搅拌。当厚度超出30cm时,应分层搅拌。1.2监理重点:控制白灰用量。依据铺设厚度计算出用灰量,此后和动工单位的实质进灰量进行比较。3:7灰土每立方白灰含量0.21立方〔0.245T〕,2:8灰土每立方白灰含量0.14立方。灰土搀合后,应保持必定灰土的湿度,应以手握成团,两指轻捏即碎为宜。灰土应连续进行,连忙完成,动工中应有防雨排水措施,刚打完或还没有夯实的灰土,如遭到雨淋浸泡,应将积水及柔软灰土撤掉,并补填夯实;受浸润的灰土,应晾干后再夯打密实。灰土垫层不宜冬期动工,当动工时一定采纳措施,其实不得在基土受冻的状态下铺设灰土,土料不得含有冻块,应覆盖保温,当天搀合的灰土,应当天铺完夯完,夯完的灰招待下载4优异文库土表面应用塑料薄膜和草袋覆盖保温。2.砂和砂石地基2.1正惯例定:铺筑砂〔或砂石〕的厚度,正常为150-200mm,不宜超出300mm,分层厚度可用样桩控制。视不一样条件,可采纳夯实或压实的形式。夯实可采纳平板振荡器,压实可采纳6—10吨的压路机。砂和砂石宜铺设在一致标高的基土上,如深度不一样时,基土底面应挖成踏步或斜坡形,接槎处应注意压〔夯〕实。动工应按先深后浅的次序进行。分段动工时,接槎处应作成斜坡,每层接槎处的水平间隔应错开0.5~1,并富裕压〔夯〕实。2.1.4.铺筑级配砂在夯实碾压前,应依据其干湿程度平易候条件,适合洒水润湿,以保持砂的最正确含水量,正常为8%~12%。采纳砂石办理时,应按配比在搅拌机里搅拌,不得在现场随用随调。动工时应分层找平,夯压密实,最后一层压〔夯〕完成后,表面应拉线找平,而且要吻合设规规定的标高。2.2监理重点:垫层的铺设,应待其下一层检验合格后方可动工上一层。砂石配比应平匀,不得出现石子或砂子靠拢现象。振捣一定密实,不得有漏振现象。2.2.2)砂和砂石不得含有草根等有机杂质;砂应采纳中砂;石子最大粒径不得大于垫层厚度2/3。砂石动工应连续进行,连忙完成,动工中应有防雨排水措施,刚铺筑完还没有夯实的砂石,如遭到雨淋浸泡,应将积水排走,晾干后再夯打密实。不得在基土受冻的状态下铺设砂石,砂中不得含有冻块,夯完的砂石表面应用塑料薄膜或草袋覆盖保温。砂石垫层冬期不宜动工。其余。3.1地基办理完成今后,一定经过监理查收,才能进行下一道工序,有必需时可请设计人员参加查收。3.2桩基、吻合地基一定有有资质的检测部门出具的检测文件。5.垫层正惯例定1.1垫层动工前,主要资料应有试验室出具的检测报告。水泥应有3d或7d的报告。1.2动工单位的计量器具应装备齐备,且正确有效。搅拌机旁应设置配合比标牌。试验室配合比应依据实质砂、石的含水率调理成动工配合比。砂石料场一定硬化。1.3槽底标高应吻合设计要求,用水平仪进行丈量。招待下载5优异文库1.4垫层表面应平坦,无露石现象.。监理重点:2.1检验槽底标高能否吻合设计要求。2.2目睹动工单位随机抽取标养试块和同养试块。标准修护试块:标养,就是依如实验标准来修护,以检测混凝土强度能否达到设计要求。因为固然依照设计的要求来拌和混凝土,但是因为各种原由,比如,天气、湿度、水泥批次等,还是会造成质量颠簸,所以一定检验成品能否达到设计要求。标养条件是湿度90%以上,温度20±3℃。同条件修护试块,是指依现场结构实体的修护条件进行对试块进行修护,这类条件的试块抗压强度数值反应结构实体的混凝土强度。2.3检验垫层的浇注质量:密实度、厚度、平坦度。2.4验线。内容:割方、开间尺寸。赞同偏差:长度L、宽度B〔m〕赞同偏差〔mm〕L〔B〕≤30±530<L〔B〕≤60±1060<L〔B〕≤90±15L〔B〕>90±20注:轴线的对角线尺寸的赞同偏差应为边长偏差的20.5倍;外廓轴线夹角的赞同偏差应为±1″钢筋工程正惯例定:1.1钢筋应复试合格,并应当有出厂合格证,使用复印件的应说明原件寄存处,并加盖销售单位的红章。1.2当钢筋的品种、级别或规格需作改正时,应办理设计改正文件。1.3钢筋在加工过程中,如发现脆断、焊接性能不良或力学性能明显不正常等现象,应从头进行复试。1.4直径≥18mm的钢筋可采纳焊接或机械连结,直径<18mm的钢筋可采纳绑扎。焊接形式有搭接焊、闪光对焊、电渣压力焊。搭接焊:单面焊,焊口长度10d,,双面焊5d;焊接前钢筋端部应预弯,保证焊接后两根钢筋在一致轴线上。一级钢、二级钢使用E4303焊条,三级钢采纳E5003焊条。合用直径10—40mm。闪光对焊:合用直径6—40mm的钢筋,可用于受压也可用于受拉。电渣压力焊:焊包应突出钢筋4mm,轴线位移不大于2mm,只用于受压钢筋。招待下载6优异文库1.5钢筋的接头宜设置在受力较小处。一致纵向受力钢筋不宜设置两个或两个以上接头。接头结尾至钢筋弯起点的间隔不该小于钢筋直径的10倍。当受力钢筋采纳机械连结接头或焊接接头时,设置在一致构件内的接头宜相互开。纵向受力钢筋机械连结接头及焊接接头连结区段的长度为35倍d〔d为纵向受力钢筋的较大直径〕且不小于500mm,凡接头中点位于该连结区段长度内的接头均属于一致连结区段。一致连结区段内,纵向受力钢筋机械连结及焊接的接头面积在分率为该区段内有接头的纵向受力钢筋截面面积与所有纵向受力钢筋截面面积的比值。一致连结区段内,纵向受力钢筋的接头面积百分率应吻合设计要求;当设计无详细要求时,应吻合以下规定:1在受拉区不宜大于50%;接头不宜设置在有抗震设防要求的框架梁端、柱端的箍筋加密区;当没法避开时,相同强度高质量机械连结接头,不该大于50%;直接蒙受动力荷载的结构构件中,不宜采纳焊接接头;当采纳机械连结接头时,不该大于50%。1.6一致构件中相邻纵向受力钢筋的绑扎搭接接头宜相互错开。绑扎搭接接头中钢筋的横向净距不该小于钢筋直径,且不该小于25mm。钢筋绑扎搭接接头连结区段的长度为1.3L〔L为搭接长度〕,凡搭接接头中点位于该连结区段长度内的搭接接头均属于同一连结区段。一致连结区段内,纵向钢筋搭接接头面积百分率为该区段内有搭接接头的纵向受力钢筋截面面积与所有纵向受力钢筋截面面积的比值。一致连结区段内,纵向受拉钢筋搭接接头面积百分率应吻合设计要求;当设计无详细要求时,应吻合以下规定:1对梁类、板类及墙类构件,不宜大于25%;2对柱类构件,不宜大于50%;3当工程中确有必需增大接头面积百分率时,对梁类构件,不该大于50%;对其余构件,可依据实质状况放宽。1.7钢筋搭接地域内,最少应绑扎三道扎丝,中间一道,两头各一道。1.8最外侧凑近基础模板边的钢筋和模板的间隔为5cm。1.9正常状况先铺短向钢筋,再铺长向钢筋。绑扎时凑近外头两行的订交点每点都绑扎,中间部分的交点可相隔交织绑扎,双向受力的钢筋一定将交织点所有绑扎。如采纳一面顺扣应交织变换目标,也可采纳八字扣,但一定保证钢筋不位移。凡基础底板筋交叉部位,都应是双向受力部位。1.10垫块间隔1米左右,呈梅花形摆放。双层钢筋的应使用钢筋马镫,间距1米左右,呈梅花形摆放。1.11假如柱子主筋采纳光圆钢筋搭接时,角部弯钩应与模扳成45°,中间钢筋的弯钩应与模板成90°角。箍筋与主筋要笔挺,箍筋转角处与主筋交点均要绑扎,主筋与箍筋非招待下载7优异文库转角部分订交点成梅花交织绑扎。柱筋在基础梁高限制内,应许多于3个箍筋,柱脚钢筋无设计要求时,平直段不该少于25cm.。箍筋的弯钩叠合处应沿柱子竖筋交织部署,并绑扎牢靠。有抗震要求的地域,柱箍筋端头应弯成135°,平直部分长度不小于10d(d为箍筋直径〕。柱基、柱顶、梁柱交接处箍筋间距应按设计要求加密。柱上下两头箍筋应加密,加密区长度及加密区内箍筋间距应吻合设计图纸要求。1.12梁端第一个箍筋应设置在间隔柱节点边沿50mm处。梁端与柱交接处箍筋应加密。1.13钢筋安装赞同偏差项目项次项目赞同偏差1绑扎钢筋网的长与宽±102绑扎钢筋网网眼尺寸±203绑扎钢筋骨架宽度、高度±54绑扎钢筋骨架长度±105受力筋间距±106受力筋排距±57钢筋弯起点位移208绑扎箍筋、横向钢筋间距±20平高差+39焊接预埋件中心线位移5基础±1010受力筋保护层梁柱±5墙板±3监理重点2.1检验复试报告能否合格。2.2检验焊接质量、绑扎长度、接头地点能否吻合标准要求。当焊口质量不吻合要求时,可采纳挽救措施,在焊口处加一根增强筋,直径同焊接钢筋直径,长度为焊口每侧一个搭接长度。2.3检验负筋的地点能否能保证。检验柱钢筋的定位措施,必需时要求加设牢靠钢筋〔图〕。挑梁的箍筋张口处应朝下。招待下载8优异文库2.4检验箍筋的平直段长度、受力主筋的锚固长度,检验柱、梁、板钢筋及其骨架的地点能否正确,数目及直径能否吻合图纸要求。2.4十字、丁字交织处底板钢筋的办理:底板横向受力钢筋仅沿一个主要受力目标凡是布置,另一目标的横向受力钢筋可部署到主要受力目标底板宽度1/4处。度交织处底板钢筋的办理:底板横向受力钢筋应沿两个目标部署。2.5钢筋保护层是指主筋的保护层厚度,即从主筋外观面至构件表面的间隔。基础梁箍筋外包尺寸高度的计算:设计截面高度-上部保护层厚度〔正常设计为5cm〕-下部保护层厚度-基础梁下底板筋直径。图:2.6第一次基础验筋,现场检验合格后,建设单位应当通知质检站查收。招待下载9优异文库模板工程1.0正惯例定:1.1模板及其支架应拥有足够的承载本事、刚度和坚固性,能靠谱的蒙受浇注混凝土的重量。1.2基础梁超出条形基础部分,应支吊模,保证基础梁混凝土一次浇注。1.3基础圈梁的模板一定顺直,有靠谱的加固措施。浇注混凝土时,操作平台禁止压在圈梁模板上。1.4模板与混凝土的接触面应涂间隔剂。禁止间隔剂沾污钢筋和混凝土接槎处。1.5支模前要把结构柱底部及马牙槎处砖块上边的浮灰和垃圾去除洁净,并用水进行冲洗,再立模板进行浇捣混凝土。2.0监理重点:2.1拉线或用经纬仪检验模板的顺直度。2.2检验模板的尺寸、牢靠程度。2.3基础梁上翻部分一定支吊模。2.4禁止混凝土操作平台直接压在模板上。混凝土基础正惯例定:1.1混凝土浇注前主要资料的合格证、出厂报告、复试报告一定齐备。混凝土中掺外加剂的一定到试验室做特地的配合比。1.2搅拌混凝土前,宜将搅拌筒富裕润滑。搅拌第一盘时,宜按配合比减少粗骨料用量。在所有混凝土卸出以前不得再加入搀合料,更不得采纳边出料边进料的形式进行搅拌。1.3混凝土一定做开盘判断。混凝土搅拌中一定严格控制水灰比和坍落度,禁止任意调理用水量。动工单位的计量器具应装备齐备,且正确有效。搅拌机旁应设置配合比标牌。掺外加剂时,应安排专人和专用工具。原资料每盘称量的赞同偏差资料称号赞同偏差水泥、掺合料±2%粗、细骨料±3%水、外加剂±2%1.4混凝土浇筑时钢筋工、木匠都应安排专人盯护。1.5使用插入式振捣棒应快插慢拔,插点要平匀,逐点一动,次序进行,不得遗漏,做到平匀振实。挪动间距不大于振捣作用半径的1.5倍(正常为30-40cm)。振捣上一层招待下载10优异文库时应插入基层5cm,以除去两层间的接缝。表面振捣器的挪动间距,应保证振荡器的平板覆盖已振实部分的边沿。振捣至砼表面出现浮浆和砼不再下沉为止。1.6留动工缝时应提早判定留槎地点,用模板支护好,动工缝处一定振捣密实。再进行施工时,对付动工缝处凿毛,此后刷灰浆,其配合比与混凝土内的沙浆成分相同.1.7混凝土浇筑完成后,应按动工技术规划即时采纳有效的修护措施,并应吻合以下规定:a.应在浇筑完成后的12h之内对混凝土加以覆盖并保湿修护;b.混凝土浇水修护的时间:对采纳硅酸盐水泥、一般硅酸盐水泥或矿渣硅酸盐水泥拌制的混凝土,不得少于7d;对掺用缓凝型外加剂或有抗渗要求的混凝土,不得少于14d;c.浇水次数应能保持混凝土处于润湿状态;混凝土修护用水应与拌制用水相同;d.采纳塑料布覆盖修护的混凝土,其敞露的所有表面应覆盖精密,并应保持塑料布内有凝固水;5混凝土强度达到1.2N/mm2前,不得在其上践踏或安装模板及支架。注:1、当天均匀气温低于5℃时,不得浇水;1.8拆模后若有质量缺点,动工单位不得私自办理,一定报经监理后才可办理。现浇结构外观质量缺点称号现象重要缺点正常缺点构件内钢纵向受力筋未被混其余钢筋露筋钢筋有露凝土包裹筋有少许露而外露筋混凝土表面缺乏水构件主要其余部位蜂窝泥沙浆而受力部位有少许蜂产生石子有蜂窝窝外露混凝土中孔穴深度构件主要其余部位孔洞和长度均受力部位有少许孔超出保护有孔洞洞层厚度混凝土中夹有杂物构件主要其余部位夹渣且深度超受力部位有少许夹过保护层有夹渣渣厚度招待下载11优异文库混凝土中构件主要其余部位蓬松局部不密受力部位有少许疏实有蓬松松构件主要其余部位漏洞从混受力部位有少许不凝土表面有影响结影响结构裂痕延长至混构性能或性能或使凝土内部使用功能率功能的的裂痕裂痕构件连结连结部位处混凝土连结部位连结有基本不缺点及连有影响结部位影响结构接钢筋、构传力性缺点传力性能连结件松能的缺点的缺点动缺棱掉清水混凝其余混凝角、棱土构件有土构件有外形角不直、影响使用不影响使缺点翘曲不功能或装用功能的平、飞边饰成效的外形缺点凸肋等外形缺点构件表面拥有重要其余混凝装饰成效麻面、掉土构件有外观的清水混皮、起不影响使缺点凝土构件砂、沾污有外观缺用功能的等外观缺点陷1.9冬期动工:室外日均匀气温连续5天坚固低于5℃即进入冬期动工;当室外日平均气温连续5天坚固高于5℃时除去冬期动工。1.10冬期动工宜采纳综合蓄热法。a.对原资料和水进行加热,热水加热不得超出80℃。投料次序:先投粗细骨料,骨料和热水搅拌后,在加入水泥。c.出灌温度不低于10℃,入模温度不低于5℃.浇筑后应随即进行覆盖,宜先盖一层塑料薄膜,此后再盖棉毡一层。监理重点:招待下载12优异文库2.1检验动工单位人员落真相况。2.2每日对动工单位的配比状况检验许多于3次,严格控制混凝土的塌落度,以在料斗中能“立住”为宜。2.3在修护期内应保持混凝土表面润湿。2.4对混凝土基础进行查收。查收内容:顶面放线、截面尺寸、标高、浇筑质量。如发现重要品诘问题应请设计部门办理。2.5冬天动工时检验冬天动工措施能否到位,用温度计检验混凝土出灌、入模温度。砖基础正惯例定:1.1砖在砌筑时应提早1-2天浇水润湿。正常以水侵入砖四边1.5cm为宜,含水率为10%-15%,常温动工不得与干砖上墙,雨季不得使用含水率达饱和状态的砖砌墙,冬期浇水有困难时,一定适合增大沙浆稠度。1.2严格按动工配合比配制沙浆。不宜使用沙浆王等外加剂来提升沙浆的和易性。1.3砌砖:砌砖宜采纳挤浆法,或采纳三一砌砖法。三一砌砖法的操作重点是一铲灰、一块砖、一挤揉,并顺手将挤出的沙浆刮去,操作时砖块要放平,跟线。禁止出现板凳灰。1.4挂线:240墙宜双面挂线,370墙双面挂线。墙体转角处设置皮数杆。1.5砖墙水平灰缝和竖向灰缝宽度正常为10毫米,但不该小于8毫米,也不大于12毫米。水平灰缝的沙浆丰满度应不低于80%。水泥标砖沙浆丰满度不低于90%1.6240mm厚承重墙的每层承重墙上最上一皮砖,应是整砖丁砌。在梁也许梁垫的下边及挑檐、腰线等处,也应是整砖丁砌。1.7砌体组砌形式应正确,上下错缝〔上下皮砖搭接应不小于25mm〕,表里搭砌;灰缝应横平竖直,厚薄平匀;柱、垛无包心砌法、无暗通缝。不得出现瞎缝、透缝现象。1.8砌筑沙浆一定搅拌平匀,随拌随用,盛入灰槽〔盆〕内的沙浆若有泌水现象时,应在砌筑前从头拌和。水泥沙浆和水泥混淆沙浆应辩解在拌成后3h和4h内用完,动工期间最高气温超出30℃,一定辩解在2-3小时内用完。监理重点2.1检验砖的含水率,能否有干砖上墙。2.2检验粘灰率。检验形式:用百格网或目测检验砖底面与沙浆的粘结印迹面积,连揭3块砖,取其均匀值。2.3检验砖砌体标高能否吻合设计要求。2.4检验结构柱的截面尺寸。2.5找平厚度超出30mm的,应使用细石混凝土。防潮层招待下载13优异文库正惯例定:1.1防潮剂或防潮粉应有出厂合格证及检测报告。1.2基层应清理洁净,防潮层动工前应浇水润湿并甩浆。1.3防潮层厚度对付合设计要求。监理重点:2.1防潮层应和基层接触精密,不得有空鼓、起砂现象。2.2防潮层表面应平坦圆滑,不得有砂眼现象。2.3防潮层应到柱的保护层边沿为止,不得浸透柱的截面内。2.4防潮层的边沿应和基层宽度保持一致,不得有突出或飞刺现象。11.基础回填1.1基槽应清理洁净,无积水、杂物,架眼填堵密实。1.2基础查收合格后,方可进行回填。1.3回填时应当基础双侧同时回填,分层夯实。监理重点2.1回填时不可以破坏混凝土结构。2.2回填土不得含有有机物及其余杂质,含水率不宜过高。2.3采纳的回填土回填以前,一定做击实试验,回填后做干容重试验。招待下载14优异文库三、主体工程1.砌砖工程正惯例定:1.1主体查收前开关箱、接线盒、穿线管应安装完成,开关箱、接线盒进线管一定安装索母,不得切割箱体。开凿宽度需与管径相般配,需加钉钢丝网。1.2预留管≥三根〔总直径≥50mm〕采纳素混凝土柱,砌体高度30cm一道拉结筋。1.3预留洞口大于30cm的一定设置钢筋混凝土过梁,有引下线的采纳带凹槽的过梁板。1.4楼层放线一定经监理查收。1.5砖墙的转角处和交接处应同时砌筑,如暂时中断处留槎确有困难时,除转角外,也可留直槎,但一定做成阳槎,并加设直径6mm拉结筋,间距沿墙不得超出500mm,深入墙体许多于500mm。1.6结构柱拉结筋的形状应吻合设计要求,设计无要求时,应使用端部有弯折的,弯折长度不小于150mm,端部设弯钩,弯钩长度不低于50mm,弯折处深入结构柱截面内不小于50mm。1.7马牙槎应先退后进。1.8安装砼过梁,底部一定座浆。砼过梁每边支座不得小于250mm。1.9太阳能预留孔砌块上下搭接尺寸不小于120mm,每隔两块高度搁置一道拉结筋。1.10半砖不得靠拢使用,二分头不得上墙。1.11暂时动工洞口的留置距纵横墙交接处的间隔应≥500mm,洞口尺寸不得大于1000mm*1500mm。1.12其余规定见基础砌体部分。监理重点:2.1检验拉结筋的搁置数目,超出500mm高度,一定搁置一道拉结筋。2.2检验窗台下部抗裂筋的搁置。2.3检验柱、垛能否有暗通缝现象。2.4检验砼过梁的强度及配筋,检验太阳能预留空砌块的强度,介绍使用结构柱内预留直径110mmPUC管的动工形式。2.5检验洗手间防水墙的强度。2.混凝土多孔砖工程正惯例定:1.1动工时所使用的砼多孔砖的产品龄期不该小于28d。推行证书、节能证书、合格证齐备有效。1.2砖块堆码的园地要平坦并保持干燥。堆放的园地要易于排水,周边应设排沟渠,防止底部砖块浸水,下雨时要采纳覆盖措施,防止砖块被雨淋湿。1.3砖块一定干砌,被雨淋湿和含水率高的砖块绝对不可以上墙;在高温干燥天气时动工,如果砖块过于干燥时,可适合喷水润湿后再砌筑,不得浇水润湿。1.4表面粘着泥及杂物等不洁净的砖块要清理洁净才能用于砌筑;其余资料制作的砖块〔如招待下载15优异文库黏土砖等〕不可以与混凝土多孔砖混砌,因不一样材质的砖块缩短率是不一样的,砌体易产生裂痕。1.5灰缝厚度。砌体的水平灰缝厚度和笔挺灰缝宽度应控制在8-12mm之间,而且要求横平、竖直。灰缝丰满度不低于90%。为保证沙浆丰满度,要勾缝。勾缝要随砌随勾。最正确用稍粗的建筑用圆钢钢筋弯成一个弯头,把灰缝中挤出来的沙浆往里轻推,产生凹形的灰缝沟并凹进墙面2㎜,既雅观,又能够提升沙浆的密实度和沙浆与砖块联合的慎密度,同时还能够提升抹灰层与砌体基层的粘结牢靠度。1.6新砌好的砌体在7天内要妥当保护,防止碰撞,防守沙浆与砖块松动。在砌筑时发现砌体倾斜或砌筑不够平坦时,只好拆掉重砌,不可以用敲击砌体的形式进行砌体校订。1.7夏天高温时,在砌筑的次日,对付砌体进行修护。可用喷雾器喷水修护。这样能够减慢砌体的干燥,提升沙浆的强度和与砖块的粘结牢度。1.8每天砌筑的高度不该超出1.4m。1.9最下边三皮砼多孔砖应孔向上使用。随砌随用沙浆把孔填实。监理重点:2.1禁止对砼多孔砖进行浇水。2.2检验勾缝后灰缝的密实度。2.3夏天高温时,应要求动工单位安排专人对墙体进行修护。修护期不低于7天。3.钢筋工程正惯例定:1.1绑扎时,单向板可间隔绑扎,但外头两排一定全数绑扎。双向板一定全数绑扎。长宽比小于3的现浇板为双向板。监理重点:2.1结构柱位移时应采纳从头生根、加增强钢筋等办理方法。2.2检验结构柱箍筋的数目、搭接部位的绑扎形式。2.3检验预留洞口能否采纳增强措施。4.模板工程正惯例定:1.1竖向模板和支架的支撑部分,当安装在基土上时,应加设垫板,且基土一定坚固并有排水措施。楼层间的上下支柱应在一条直线上。梁正常支柱间距为60-100cm现浇板支柱间距以80-120cm为宜,支柱之间应拉结。当梁跨度≥4m时,跨中梁底处应按设计要求起拱,如设计无要求,起拱高度宜为梁跨度的1/1000-3/1000。1.2承重部分、悬挑结构模模板拆掉,一定经监理工程师赞同。1.3模板拆掉应注意拆模的次序,正常是先支后拆,后支先拆,先拆非承重部分后拆承重部分,拆底模时以同条件修护砼试块抗压强度为准,并应吻合标准要求,拆侧模以砼强度能保证其表面棱角不因拆膜受损为准。招待下载16优异文库底模拆掉时的混凝土强度要求构件种类构件跨度〔m〕达到设计的同立方体抗压强度标准值的百分率〔℅〕板≤2≥50>2,≤8≥75>8≥100梁拱壳≤8≥75>8≥100悬臂构件--≥100监理重点:1.1查收钢筋前,应先查收模板工程。内容:模板支柱间距、拉结;模板标高;截面尺寸;精密程度。1.2支柱支撑在基土上时,一定检验基土的坚固度、垫板和排水措施。1.3检验边柱、露台柱等突出部位模板的笔挺度。5.0砼工程正惯例定:1.1重点部位动工应旁站。1.2浇注砼柱时,柱跟应填5-10cm沙浆。沙浆成分同砼内沙浆成分。1.3动工缝留置:工缝的设置:混凝土动工缝不该任意留置,其地点应按设计要乞降动工技术规划早先判定,判定动工缝的原则为:尽也许留置在受剪力较小的部位,留置部位应便于动工。①和板连成整体的大断面梁,留置在板底面以下20~30mm处。②单向板,留置在平行于板的短边的任何地点。③有主次梁的楼板,宜顺着次梁目标浇筑,动工缝应留置在次梁跨度的中间三分之一限制内。④楼梯的动工缝应留置在楼梯段1/3的部位。动工缝应笔挺于楼梯板留置。1.4梁、柱节点钢筋较密时,浇筑此处混凝土时宜用小粒径石子同强度等级的混凝招待下载17优异文库土浇筑,并用小直径振捣棒振捣。1.5楼梯段混凝土自下而上浇筑,先振实底板混凝土,达到踏步地点时再与踏步混凝土一同浇捣,不停连续向上促使,并随时用木抹子(或塑料抹子)将踏步上表面抹平。1.6浇筑板混凝土的虚铺厚度应略大于板厚,用平板振捣器笔挺浇筑目标来回振捣,厚板可用插入式振捣器振捣,并用铁插尺检验混凝土厚度,振捣完成后用木抹子抹平。动工缝处或有预埋件及插筋处用木抹子找平。浇筑板混凝土时禁止用振捣棒铺摊混凝土。1.7板动工缝处的支护办理:1.8楼层放线一定经监理工程师查收,合格后才赞同进行下道工序动工。监理重点2.1旁站时应填写旁站记录,严格控制水灰比。2.2现浇板砼初凝后用“带尖”的钢筋检验现浇板厚度。2.3动工单位拆掉承重模板前一定报经监理工程师赞同。2.4检验梁头、柱根能否振捣密实,现浇板找平能否吻合要求。2.5检验修护落真相况。6.预制空心楼板工程1.0正惯例定:1.1空心板进场后堆放在指定地址,堆放园地应平坦夯实,垫木要凑近吊环或距板端300mm,垫木上下对齐,不得有一角脱空,堆放高度不超出10块。不一样板号辩解堆放。招待下载18优异文库1.2预制空心板上应注明制作时间、板长、荷载等级、强度等级等参数。1.3预制空心楼板上墙前一定堵孔。1.4找平。空心板安装以前先将墙顶或梁项打扫洁净,检验标高及轴线尺寸,按设计要求抹水泥沙浆找平层,厚度正常为1.5~20mm,配合比为1∶3。1.5起吊时要求各吊点平匀受力,板面保持水平,防止扭翘使板开裂。禁止用“插孔法”吊装楼板。楼板搁置长度不小于80mm.1.6坐浆。楼板就位前,板底应坐浆。坐浆为1:2.5的水泥沙浆。1.7空心板之间按设规规定拉开板缝,当设计无规准时,板缝宽度正常为40mm。缝宽在60-100mm时,配一根直径8的圆钢。超出100mm时,应按设计要求配筋。1.8吊装时构件强度一定吻合设计要求,如设计无要求时,不该低于设计强度等级的70%。1.9板缝浇筑。板缝应隔层灌溉,待板缝混凝土强度达70%再进行楼面作业,板缝砼应取试块。浇筑板缝时要求应清理洁净板缝,浇水润湿,板侧刷素水泥浆〔水灰比:0.45-0.5〕,先铺15-mm厚l:2干硬性水泥沙浆,再用不低于预制板标号的干硬性细石混凝土〔坍落度l-3cm〕灌溉密实。〔用小型振捣棒振实〕。监理重点:2.1楼板使用前,对付其强度、配筋进行检验,并检验板身有无裂纹。2.2严格控制板缝宽度,不得小于40mm.2.3检验板底标高。2.4检验板缝内配筋、板缝砼强度。招待下载19优异文库四、装饰、装饰分部一、抹灰工程正惯例定1.1外墙及有防水要求的部位〔如厨厕〕墙面应采纳抹水泥沙浆。1.2采纳32.5及其以上硅酸盐水泥或一般硅酸盐水泥,禁止不一样品种的水泥混用。需对水泥的平定性和凝固时间进行复试。1.3抹灰前应检验门窗的地点能否正确,与墙体连结能否牢靠。连结处和漏洞应用1:3水泥沙浆或1:1:6水泥混淆沙浆分层嵌塞密实。铝合金门窗框漏洞所用嵌缝资料应吻合设计要求,并早先粘贴好保护膜。1.4对混凝土表面缺点如蜂窝、麻面、露筋等应剔到实处,并刷素水泥浆一道〔内掺水重10%的107胶〕,紧跟用1:3水泥沙浆分层补平1.5管道穿越墙洞、楼板洞应即时部署套管,并用1:3水泥沙浆或细石混凝土填嵌密实;电线管、消火栓箱、配电箱安装完成,并将背后露明部分钉好钢丝网;接线盒用纸堵严。1.6抹灰工程应分层进行。当抹灰总厚度大于或等于35mm时,应采纳增强措施。不一样材料基体交接处表面的抹灰,应采纳防守开裂的增强措施,当采纳增强网时,增强网与各基体的搭接宽度不该小于100mm。使用砼砖标准砖、砼多孔砖、砼加气块的墙体,宜表里墙都加钢丝网。1.7抹灰层与基层之间及各抹灰层之间一定粘结牢靠,抹灰层应无脱层、空鼓,面层应无爆灰和裂痕。1.8正常抹灰的赞同偏差和检验形式项赞同偏差次项目一般抹灰高级抹灰检验形式1立面笔挺度43用2m笔挺检测尺检验2表面平坦度43用2m靠尺和塞尺检验3阴阳角方正43用直角检测尺检验4分格条〔缝〕43用5m线,不足5m拉通线,用钢直直线度尺检验5墙裙、勒脚43拉5m线,不足5m拉通线,用钢直上口直线度尺检验招待下载20优异文库注:1〕一般抹灰,本表第3项阴角方正可不检验;2〕顶棚抹灰,本表第2项表面平坦度可不检验,但应平顺。1.9分户墙、楼梯间墙、应抹保温沙浆。2.监理重点2.1当要求抹灰层拥有防水、防潮功能时,应采纳防水沙浆2.2室内墙面、柱面和门洞口的阳角做法应吻合设计要求。当设计无要求时,应采纳1:2水泥沙浆做暗护角,其高度不该低于2m,每侧宽度不该小于50mm。2.3抹灰前板缝间要加防裂网。2.4要对抹灰沙浆的配合比进行检验。2.5禁止使用沙浆王等外加剂。2.6标准间动工完成经过监理查收后,再赞同动工单位通知质检站进行查收。2.7注意抹灰工程的笔挺,平坦以及阴阳角的顺直。特别要注意门窗洞口的阴阳角顺直。2.8烟道与墙交接处,过人洞口等处抹灰前要加挂防裂网。2.9外墙做保温的,其抹灰应保证平坦笔挺、压水光即可。2.10墙面抹灰要求表面平坦,色彩平匀,接槎不明显,无表面开裂,不一样意出现空鼓现象。2.11室内顶棚宜采纳免抹灰工艺,当顶棚抹灰时,抹灰层与基层之间一定粘结牢靠,无空鼓。二、地暖工程正惯例定1.1地暖动工前,楼地面找平层应检验完成。1.2分集水器用4个膨胀螺栓水平牢靠在墙面上,安装要牢靠。1.3沿表里墙设伸缩缝,用10mm厚聚苯板条填塞,高度同垫层厚,用胶和墙体粘牢。当房间边长超出6m或面积超出36平方时也应设置伸缩缝,用聚苯板条填塞,高度同垫层厚。地暖管穿越伸缩缝时,应设置长度不小于400mm的柔性套管。在分水器及加热管道靠拢处,管外用不短于1000mm的涟漪管保护,以变低混凝土热膨胀。在缝中填补弹性膨胀膏〔或进口弹性密封胶〕。1.4垫层应用人工抹压密实,不得用机械振捣。1.5回填应用细石砼,动工应保证砼设计强度,不得出现砼柔软、起砂、露管现象。砼内不得参杂建筑垃圾等废料,砼表面应拉毛。1.6立管与分集水器连结后,应进行系统试压。试验压力为系统极点工作压力加0.2Mpa,且不小于0.6Mpa,10分钟内压力降不大于0.02Mpa,降至工作压力后,不渗不漏为合格。供热支管后的分派器查收后,对付整个供水环路水温及水力均衡进行调试。采暖向地板招待下载21优异文库供水时,应采纳预热形式,供热水温不得蓦地高升,初始供水温度应为20℃~25℃,保持3天,此后以最高设计温度保持4天,并以≤50℃水温正常运行。监理重点1地面下敷设的盘管埋地部分不该有接头。2.2盘管隐蔽前一定进行水压试验,试验压力为工作压力的1.5倍,但不小于0.6MPa。2.3地热管穿越伸缩缝处,应设长度不小于lOOmm的柔性套管。2.4地热管长度宜尽量凑近,其实不宜超出120m。2.5检验垫层动工过程中管道的压力、伸缩条设置、砼标号、表面找平。浇筑完成后垫层表面应无漏石,表面平坦、拉毛。不一样标高处交接处,边角划一。2.6楼梯间暖通管道的保温资料应富裕圆滑,上下顺直,外观雅观。支架同管道应采纳塑性连结。。三、外墙保温工程正惯例定1.1我们当前所采纳的保温系统是聚苯板薄抹灰外墙保温系统。聚苯板薄抹灰外墙保温系统应拥有防雨水浸透性能,雨水不得透过保护层,亦不得浸透至任何也许造成破坏的部位。1.2动工前保温所用的聚苯板、胶粘剂、抹面胶浆、界面沙浆、玻纤网一定进行目睹取样试验,试验合格后才赞同动工。正常所使用的聚苯板的表观密度为18—22Kg/m3,玻纤维网的网眼尺寸,锚栓圆盘直径不小于50mm、长度不小于100mm,金属螺钉应经过防锈办理。1.3动工前一定完全去除基层表面浮灰、涂料、油污、脱模剂、空鼓及风化物等影响粘结强度的材质,基层墙面一定用水泥沙浆找平。1.4大面积动工前应先在动工墙体上做面积不小于1㎡的样板,检验其粘结强度、表面强度、平坦度、动工工艺能否吻合要求。1.5聚苯板上粘结剂的涂抹面积不得小于40%,板的侧面不得涂抹粘结剂。聚苯板间漏洞不应大于2mm,板间高差不得大于1.0mm,板缝大于2mm时应用聚苯板条将缝塞满,板条不得粘结,板间高差大于1.0mm的部位应打磨平坦。1.6洞口四角处的聚苯板应采纳聚苯板切割成型,不得拼接。接缝距四角间隔应大于200mm,且需有锚固措施,并应在洞口四角处加贴一块长300mm,宽200mm的45°斜向标准网格布。〔图〕招待下载22优异文库1.7二层及其以上墙体转角部位标准网格布应是连续的,并从每边双向绕角后包墙的宽度不小于200mm。〔图〕1.8变形缝两边聚苯板应加翻包网,缝内填塞发泡聚乙烯圆棒,其直径应为变形缝宽的1.3倍,分两次勾填嵌缝膏,深度为缝宽的50~70%。招待下载23优异文库1.9聚苯板应由勒角部位开始,自下而上,沿水平目标铺设粘贴,竖缝应逐行错缝1/2板长,在墙角处交织互锁,并应保证墙角笔挺度。如动工不可以较好几乎保墙体大角的笔挺度,抹面层沙浆时可使用成品阳角。1.10外墙窗口侧面、上下边宜采纳厚度不小于20mm的聚苯板进行保温。外窗台应有坡度,高度不得高于室内窗台。1.11标准网间应相互搭接≥100mm,分段动工时应预留搭接长度,增强网间须对接,其对接处应慎密对接。网格布的曲折面朝向墙面,并从中央向四周用抹子抹平,直至玻纤网完好嵌入抹面胶浆内。1.12装饰线条应采纳与墙体保温资料性能相同的聚苯板。外墙面上的雨水管卡、预埋铁件、设备穿墙管等安装时不可以破坏保温层,并按设计要求留出外保温层的厚度。1.13调好的沙浆宜在1小时内用完。干混沙浆只需加入净水,不可以加入任何其余增加剂。1.14七层以下锚栓的部署图。2.监理重点2.1要求动工单位提交动工规划、所用产品的各项证件,并目睹取样、送检。。2.2要侧重检验苯板的粘接面积,牢靠件个数,门窗洞口网格布及反包增强网。2.3外墙保温大阳角处宜采纳成品护角。2.4空调管道、暖气管道等穿墙管道的套管一定在外墙保温前动工完成。落水管道的安装宜由保温队列动工。套管四周、落水管道牢靠件处应有防水措施。2.5检验外墙窗口的竖向顺直度。四、室内防水工程正惯例定1.1动工单位应供应动工规划和所采纳资料的合格证、复试报告。使用新式资料的应有推行证书和使用说明。1.2操作工艺:安装、预留洞、管道就位→捶口→灌水实验→找平层→防水层→灌水实验→面砖→灌水实验。1.3所有楼板的管洞、套管洞四周的漏洞均用掺加膨胀剂的细石混凝土灌溉严实抹平,待全招待下载24优异文库部办理完后进行灌水实验,24h无渗漏,监理查收后方可进行下道工序的动工。1.3找平层完成后,表面应坚固平坦、洁净无空鼓松动、明显裂痕、麻面、起砂等现象,否则应用水泥胶腻子维修,使之光滑。找平层的坡度应吻合设计要求,坡度坡向地漏。所有转角处一律做成半径10mm的平匀一致的光滑圆角,所有管件、地漏或排水口等部位一定就位正确,安装牢靠,不得有任何松动现象。1.4卷材上翻高度限制内的墙面抹灰应压光,要求平坦,无空鼓、裂痕、起砂等缺点。正常上翻高度不小于300mm。采纳防水涂料时,墙面涂刷高度也不该低于300mm。1.5在墙面和地面订交的阴角处,出楼面管道根部和地漏四周,须增加附带层。1.6防水层动工时找平层应平坦,用笤帚将灰尘、砂粒等杂物打扫洁净,特别是管根、地漏和排水口等部位要认真清理。若有油污时,应用钢丝刷和砂纸刷掉。对基层有干燥要求的,基层达到干燥要求后才能进行动工。1.7防水层动工完成后,要求动工单位进行蓄水试验。将地漏、下水口和门口处暂时封堵,蓄水深度20~30mm,蓄水24h后,检验无渗漏经监理查收后,再进行面层动工。1.8面层动工应注意保护防水层,禁止在防水层上拌制沙浆。管道穿楼面处应做阻水台。高度不低于30mm,阳角应磨角对缝,管根部要套割,周边漏洞不大于5mm。阻水台应从防水层开始做,不得直接做在面砖上。1.9面层动工完成要求动工单位进行蓄水试验。监理重点2.1检验动工单位所用资料及动工工艺。2.2捶口完成后,检验各种管道地点能否正确,管道能否笔挺。达不到要求,不得进行找平层动工。2.3检验地漏高度能否正确,地漏盖应比面层底10mm-15mm。2.4必需要求动工单位进行三次蓄水试验。〔捶口、防水层、面层〕,蓄水时间应达到24h,蓄水高度最低处不该低于20mm。2.4做淋水试验,检验面层坡向能否正确、坡度能否吻合要求、排水能否畅达。2.5埋入地面的冷热水管道不宜从洗手间门口进入洗手间。应注意门口处的防水办理。五、铝塑门窗安装正惯例定:1.1铝塑门窗的规格、型号应吻合设计要求,五金配件配套齐备,并拥有出厂合格证、材质检验
本文档为【监理手册】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
个人认证用户
自由如风
暂无简介~
格式:doc
大小:232KB
软件:Word
页数:58
分类:
上传时间:2022-09-01
浏览量:1