首页 电气预埋规范

电气预埋规范

举报
开通vip

电气预埋规范______________________________________________________________________________________________________________电气埋管施工工艺细则Electricalconduitconstructiontechnologyrules1.严禁使用电焊、气焊割管。Strictlyprohibitedinusinggasandelectricweldingcuttingconduit.2.严禁将脚手架作为电缆管使用。Stric...

电气预埋规范
______________________________________________________________________________________________________________电气埋管施工工艺细则Electricalconduitconstructiontechnologyrules1.严禁使用电焊、气焊割管。Strictlyprohibitedinusinggasandelectricweldingcuttingconduit.2.严禁将脚手架作为电缆管使用。Strictlyprohibitedinusingthefolderaselectricalconduit.3.锈蚀严重的钢管不得使用;钢管弯制或安装前应将管口及管内杂物清扫干净,并除去毛刺。Existseriouscorrosionconduitisnotallowedused;themouseoftheconduitastheinnerpartthedebrismustberemovedbeforebendingorinstallation3.电缆管切割采用手工锯或切割机进行切割,并保证切割面平整且不倾斜;切割后必须立即将管口毛刺打磨干净,并打磨管口成喇叭型。Cuttingfortheconduitadoptinginmanualsawormachine,andensurethecuttingsurfacesmoothandnottilt;burringaftercuttingmustbeimmediately,andpolishedtypenozzleintohorn.4.电缆管的弯曲半径R≥10D(电缆管外径);弯曲角度≥90°,并尽可能减少90°弯头;电缆管弯制不得出现明显的凹瘪、裂纹、折皱,钢管弯扁程度≤0.1D(电缆管外径)。BendingradiusR≥10D(hereDisconduitoutdiameter);BendingAngle≥90°,andaslessaspossiblethe90°elbow;conduitbendingcannotappearobviousconcave,crack,wrinkle,flatsteeltubebendingflatlevel≤0.1D(hereDisconduitoutdiameter).6.电缆管安装时,每根电缆管弯头数量不得超过3个,90°弯头不得超过2个(埋管长度≥12米,不得多于2个弯头;12米≥埋管长度≥8米,不得多于3个弯头;直管埋设不得大于30米)超过上述标准须增加转接盒。Wheninstallationconduit,theamountofeachconduitelbowshallnotexceed3,elbowwith90°shallnotbemorethan2;theconduitlength≥12m,shallnotbemorethantwoelbow;Thelengthoftheconduitthatchangedbetween8mand12m,shallnotbemorethanthreeelbow;straightshallnotbemorethan30meters;Ifexceedthestandardmorethanthestandardmustincreasethetransferbox.7.电缆管连接不得对接焊,必须采用短套管;套管长度≥50mm;whenconduitconnectionashortsocketmustbeused,andnobuttwelding(exceptspotwelding);thelengthofthesocketmorethan2timesofconduitoutdiameter. 电缆管型号Type 壁厚(mm)Thickness 电缆管外径(mm)Outdiameter. 连接套管内径(mm)Socketinnerdiameter 连接套管的长度(mm)Length DN25 3.25 33.5 35 ≥50mm DN32 3.25 42.3 43 ≥50mm DN50 3.5 60 61 ≥50mm DN80 4 88 89 ≥50mm8.电缆管连接时,先将套管中间凸台毛刺打磨干净,然后将电缆管插入套管中,电缆管与凸台之间不得留有间隙;连接套管与电缆管两侧均匀电焊4点,并用黑胶布缠绕封实;Whencoupling,thereshouldn’tgapbetweenthetwoconduitandthecounterpartmalocclusionislessthan2mm,counterpartseamshouldbeinthemiddleofthesocket,andthebothsidesalongthecircumferentialweldingsealing,partialcannotweldingmustuseblacktapewindingsealingwithfastenedironwire;9.电缆管不得在外壁直接点焊加固,加固采用铁丝绑扎或煨制钢筋成环钩加固、切割20~30mm套管套至固定点进行,固定间距:φ15~φ20为1.0~1.5米,φ25~φ32为1.5~2.0米,φ40~φ50为2.0~2.5米,φ65以上不大于3米。Potweldingreinforcecan’tbeallowedoutsidethewallofconduitdirectly,aavailablesteelbarwillbemadeintoaringhook,andthencutting20~30mmoneendfastentoconduitanotheronestablepointorironwirecolligationfixedspacing:φ15mm~20mmis1.0~1.0m,from25mmto32mmis1.5~1.5meters,40mm~50mmis2.0~2.5meters,exceed65mmnotmorethan3meters10.电缆管与接线盒的连接可采用焊接和丝扣连接,:电缆管伸入接线盒3~6mm管口用黑胶布包扎结实,接线盒内用湿棉纱、破布填实;外部用黑胶布缠绕,以防止水泥沙浆进入。Weldingandthreadedcanbeusedfortheconnectionbetweenelectricalconduitandsockets,electricalconduitareputtedintothesockets3~6mmThemouseoftheconduitwithblackadhesivebandage,internalpartsofthesocketfilledwithawetcottonyarn,cloth;Externalwithblacktapewinding,inordertopreventcementmortarhavingaaccessinto.11.接线盒安装时必须与 模板 个人简介word模板免费下载关于员工迟到处罚通告模板康奈尔office模板下载康奈尔 笔记本 模板 下载软件方案模板免费下载 紧贴,并用钢筋在接线盒四周加固;电缆管直径≤DN25的指明及消防报警预埋管放置于模板与钢筋网之间,预埋管绑扎在钢筋网上,与模板之间预留间隙≥15mm;电缆管在接线盒处的固定点与接线盒间距不得大于200mm。Socketmustbeclingytothetemplateandreinforcedaround,betweentheelectricalconduitandtemplatereservedclearance15mmormore.intothesocketsofthecablemustbeweldingwithacrossbar(from6or8mmroundsteel;12.所有外露预留的电缆管及伸入分电箱、木制接线盒等管口应伸出砼面200mm以上,电缆管口必须封堵。续接管路用胶布封口后加套帽。Allthereservedoutsideelectricalconduitandthoseintothedistributionbox,andwoodenboxshouldstretchouttheconcreteover200mm,addingironplateweldingseal,steelplatewithcuttingmachineandsmooth.Thecontinuedjacketedpipesetacoveraftersealingwithtape.13.电缆管过缝制作:采用在电缆管外套比电缆管外径大两级套管,套管与电缆管口部密实封堵,电缆管套管制作规格,长度如下:Manufactureforexpansionjoint,adoptingthetwolevelsofcasingpipecoatthanelectricalconduitdiameter,firstwindinglinenbetweencasingandelectricalconduitthenfillingwithasphaltclose-grained,Specifications,thelengthisasfollows: 电缆管型号Type 壁厚(mm)thickness 电缆管外径(mm)outdiameter 过缝套管规格specification 过缝套管内径(mm)Innerdiameter 过缝套管的长度(mm)length φ25 3.25 33.5 φ40 41 600 φ32 3.25 42.3 φ50 53 800 φ50 3.5 60 φ80 80.5 1200 φ80 4 88.5 φ125 131 180014.同一处电缆管超过3根,出砼必须排列整齐、美观(横平竖直);图纸没有明确要求时,按下述原则排列:(1):电缆管由大到小顺序排列;(2):3~9根可排列成一排或两排;(3):10根及以上必须排列成两排或两排以上,且每排宽度大致相当,宽度相差宜小于两根埋管的直径;(4)成排电缆管预留高度(或长度)一致。Therearemorethanthreeconduitatasameplace,theoutingconcretemustbeneat,beautiful(horizontalandvertical);Drawingswithoutclearrequirements,sortedbythefollowingprinciples:(1):frombigtosmallorder;(2):3~9piecescanbearrangedinarowortworows;(3):10andabovemustbearrangedintworowsormoreandeachrowwidthisthesame,thewidthofthedifferenceshouldbelessthanthediameteroftwoembeddedpipes;(4)rowselectricalconduitreservedheight(orlength)arethesame;WelcomeToDownload!!!欢迎您的下载,资料仅供参考!精品资料
本文档为【电气预埋规范】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
机构认证用户
金水文库
鑫淼网络科技有限公司主要经营:PPT设计 、课件制作,软文策划、合同简历设计、计划书策划案、各类模板等。公司秉着用户至上的原则服务好每一位客户
格式:doc
大小:55KB
软件:Word
页数:0
分类:
上传时间:2020-04-22
浏览量:1