开通vip

电气预埋规范电气预埋规范directly,aavailablesteelbarwillbemadeintoaringhook,andthencutting20~30mmoneendfastentoconduitanotheronestablepointorironwirecolligationfixedspacing:φ15mm~20mmis1.0~1.0m,from25mmto32mmis1.5~1.5meters,40mm~50mmis2.0~2.5meters,exceed65mmnotmorethan3meters10...

电气预埋规范
电气预埋规范directly,aavailablesteelbarwillbemadeintoaringhook,andthencutting20~30mmoneendfastentoconduitanotheronestablepointorironwirecolligationfixedspacing:φ15mm~20mmis1.0~1.0m,from25mmto32mmis1.5~1.5meters,40mm~50mmis2.0~2.5meters,exceed65mmnotmorethan3meters10.电缆管与接线盒的连接可采用焊接和丝扣连接,:电缆管伸入接线盒3~6mm管口用黑胶布包扎结实,接线盒内用湿棉纱、破布填实;外部用黑胶布缠绕,以防止水泥沙浆进入。Weldingandthreadedcanbeusedfortheconnectionbetweenelectricalconduitandsockets,electricalconduitareputtedintothesockets3~6mmThemouseoftheconduitwithblackadhesivebandage,internalpartsofthesocketfilledwithawetcottonyarn,cloth;Externalwithblacktapewinding,inordertopreventcementmortarhavingaaccessinto.11.接线盒安装时必须与模板紧贴,并用钢筋在接线盒四周加固;电缆管直径≤DN25的指明及消防报警预埋管放置于模板与钢筋网之间,预埋管绑扎在钢筋网上,与模板之间预留间隙≥15mm;电缆管在接线盒处的固定点与接线盒间距不得大于200mm。Socketmustbeclingytothetemplateandreinforcedaround,betweentheelectricalconduitandtemplatereservedclearance15mmormore.intothesocketsofthecablemustbeweldingwithacrossbar(from6or8mmroundsteel;12.所有外露预留的电缆管及伸入分电箱、木制接线盒等管口应伸出砼面200mm以上,电缆管口必须封堵。续接管路用胶布封口后加套帽。Allthereservedoutsideelectricalconduitandthoseintothedistributionbox,andwoodenboxshouldstretchouttheconcreteover200mm,addingironplateweldingseal,steelplatewithcuttingmachineandsmooth.Thecontinuedjacketedpipesetacoveraftersealingwithtape.13.电缆管过缝制作:采用在电缆管外套比电缆管外径大两级套管,套管与电缆管口部密实封堵,电缆管套管制作规格,长度如下:Manufactureforexpansionjoint,adoptingthetwolevelsofcasingpipecoatthanelectricalconduitdiameter,firstwindinglinenbetweencasingandelectricalconduitthenfillingwithasphaltclose-grained,Specifications,thelengthisasfollows:电缆管型号Type壁厚(mm)thickness电缆管外径(mm)outdiameter过缝套管规格specification过缝套管内径(mm)Innerdiameter过缝套管的长度(mm)lengthφ253.2533.5φ4041600φ323.2542.3φ5053800φ503.560φ8080.51200φ80488.5φ125131180014.同一处电缆管超过3根,出砼必须排列整齐、美观(横平竖直);图纸没有明确要求时,按下述原则排列:(1):电缆管由大到小顺序排列;(2):3~9根可排列成一排或两排;(3):10根及以上必须排列成两排或两排以上,且每排宽度大致相当,宽度相差宜小于两根埋管的直径;(4)成排电缆管预留高度(或长度)一致。Therearemorethanthreeconduitatasameplace,theoutingconcretemustbeneat,beautiful(horizontalandvertical);Drawingswithoutclearrequirements,sortedbythefollowingprinciples:(1):frombigtosmallorder;(2):3~9piecescanbearrangedinarowortworows;(3):10andabovemustbearrangedintworowsormoreandeachrowwidthisthesame,thewidthofthedifferenceshouldbelessthanthediameteroftwoembeddedpipes;(4)rowselectricalconduitreservedheight(orlength)arethesame;
本文档为【电气预埋规范】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
个人认证用户
文艺人生
暂无简介~
格式:doc
大小:4MB
软件:Word
页数:7
分类:
上传时间:2022-06-20
浏览量:0