SX440,STAMFORD,调压板英文说明书 DESIGN DETAIL TD_SX440 AVR_03.05_03_GB SX440 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION, INSTALLATION AND ADJUSTMENTS General description Technical specification SX440 is a half-wave phase-controlled thyristor type Automatic Voltage...

SX440,STAMFORD,调压板英文说明书
DESIGN DETAIL TD_SX440 AVR_03.05_03_GB SX440 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION, INSTALLATION AND ADJUSTMENTS General description Technical specification SX440 is a half-wave phase-controlled thyristor type Automatic Voltage Regulator (AVR) and forms part of the excitation system for a brush-less generator. In addition to regulating the generator voltage, the AVR circuitry includes under-speed and sensing loss protection features. Excitation power is derived directly from the generator terminals. Positive voltage build up from residual levels is ensured by the use of efficient semiconductors in the power circuitry of the AVR. The AVR is linked with the main stator windings and the exciter field windings to provide closed loop control of the output voltage with load regulation of +/- 1.0%. In addition to being powered from the main stator, the AVR also derives a sample voltage from the output windings for voltage control purposes. In response to this sample voltage, the AVR controls the power fed to the exciter field, and hence the main field, to maintain the machine output voltage within the specified limits, compensating for load, speed, temperature and power factor of the generator. A frequency measuring circuit continually monitors the generator output and provides output under-speed protection of the excitation system, by reducing the output voltage proportionally with speed below a pre-settable threshold. A manual adjustment is provided for factory setting of the under frequency roll off point, (UFRO). This can easily be changed to 50 or 60 Hz in the field by push- on link selection. Provision is made for the connection of a remote voltage trimmer, allowing the user fine control of the generator's output. An analogue input is provided allowing connection to a Newage Power Factor controller or other external devices with compatible output. The AVR has the facility for droop CT connection, to allow parallel running with other similarly equipped generators. INPUT Voltage 190-264V ac Frequency 50-60 Hz nominal Phase 1 Wire 2 OUTPUT Voltage max 90V dc at 207V ac input Current continuous 4A dc Intermittent 6A for 10 secs Resistance 15 ohms minimum REGULATION +/- 1% (see note 1) THERMAL DRIFT 0.04% per deg. C change in AVR ambient (note 2) TYPICAL SYSTEM RESPONSE AVR response 20ms Filed current to 90% 80 ms Machine Volts to 97% 300ms EXTERNAL VOLTAGE ADJUSTMENT +/-10% with 1 k ohm 1 watt trimmer (see note 3) UNDER FREQUENCY PROTECTION Set point 95% Hz (see note 4) Slope 170% down to 30 Hz UNIT POWER DISSIPATION 12 watts maximum BUILD UP VOLTAGE 4 Volts @ AVR terminals ANALOGUE INPUT Maximum input +/- 5V dc (see note 5) Sensitivity 1v for 5% Generator Volts (adjustable) Input resistance 1k ohm QUADRATURE DROOP INPUT 10 ohms burden Max. sensitivity: 0.07 A for 5% droop 0PF Max. input: 0.33A ENVIRONMENTAL Vibration 20-100 Hz 50mm/sec 100Hz – 2kHz 3.3g Operating temperature -40 to +70 oC Relative Humidity 0-70 oC 95% (see note 6) Storage temperature -55 to +80 oC NOTES 1. With 4% engine governing. 2. After 10 minutes. 3. Applies to Mod status S onwards. Generator de-rate may apply. Check with factory. 4. Factory set, semi-sealed, jumper selectable. 5. Any device connected to the analogue input must be fully floating (galvanically isolated from ground), with an insulation strength of 500V ac. 6. Non condensing. ww w. we llf ut .co m DESIGN DETAIL TD_SX440 AVR_03.06_03_GB The main functions of the AVR are: Potential Divider and Rectifier takes a proportion of the generator output voltage and attenuates it. The potential divider is adjustable by the AVR Volts potentiometer and external hand trimmer (when fitted). The output from the droop CT is also added to this signal. An isolating transformer is included allowing connection to various winding configurations. A rectifier converts the a.c. input signal into d.c. for further processing. The Sensing Loss Detector is an electronic changeover switch, which normally connects the Amplifier (Amp) to the Voltage Sensing input and automatically changes over to the Power input when the normal sensing voltage is lost. The DC Mixer adds the Analogue input signal the Sensing signal. The Amplifier (Amp) compares the sensing voltage to the Reference Voltage and amplifies the difference (error) to provide a controlling signal for the power devices. The Ramp Generator and Level Detector and Driver infinitely control the conduction period of the Power Control Devices and hence provides the excitation system with the required power to maintain the generator voltage within specified limits. The Stability Circuit provides adjustable negative ac feedback to ensure good steady state and transient performance of the control system. The Low Hz Detector measures the period of each electrical cycle and causes the reference voltage to be reduced approximately linearly with speed below a presettable threshold. A Light Emitting Diode gives indication of underspeed running. The Synchronising circuit is used to keep the Ramp Generator and Low Hz Detector locked to the generator waveform period. The Low Pass Filter prevents distorted waveforms affecting the operation of the AVR control circiut Power Control Devices vary the amount of exciter field current in response to the error signal produced by the Amplifier. Suppression components are included to prevent sub cycle voltage spikes damaging the AVR components and also to reduce the amount of conducted noise on the generator terminals.. The Power Supply provides the required voltages for the AVR circuitry. Suppression Low Pass Filter Synchronising Circuit Low Hz Detection Power Control Devices Level Detector & Driver Reference Voltage Stability Circuit Potential Divider & Rectifier Power supply Ramp Generator Generator Amp Voltage Sensing Hand Trimmer Exciter Field DC Mixer Analogue Input Sensing Loss Detector Droop ww w. we llf ut .co m FITTING AND OPERATING TD_SX440 AVR _03.06_03_GB SUMMARY OF AVR CONTROLS CONTROL FUNCTION DIRECTION VOLTS TO ADJUST GENERATOR OUTPUT VOLTAGE CLOCKWISE INCREASES OUTPUT VOLTAGE STABILITY TO PREVENT VOLTAGE HUNTING CLOCKWISE INCREASE THE DAMPING EFFECT UFRO TO SET THE UFRO KNEE POINT CLOCKWISE REDUCES THE KNEE POINT FREQUENCY DROOP TO SET THE GENERATOR DROOP TO 5% AT 0PF CLOCKWISE INCREASES THE DROOP VTRIM TO OPTIMISE ANALOGUE INPUT SENSITIVITY CLOCKWISE INCREASES THE GAIN OR SENSITIVITY ADJUSTMENT OF AVR CONTROLS VOLTAGE ADJUSTMENT The generator output voltage is set at the factory, but can be altered by careful adjustment of the VOLTS control on the AVR board, or by the external hand trimmer if fitted. Terminals 1 and 2 on the AVR will be fitted with a shorting link if no hand trimmer is required. CAUTION Do not increase the voltage above the rated generator voltage. If in doubt, refer to the rating plate mounted on the generator case. CAUTION Do not ground any of the hand trimmer terminals as these could be above earth potential. Failure to observe this could cause equipment damage. If a replacement AVR has been fitted or re-setting of the VOLTS adjustment is required, proceed as follows: CAUTION 1. Before running generator, turn the VOLTS control fully anti-clockwise. 2. Turn remote volts trimmer (if fitted) to midway position. 3. Turn STABILITY control to midway position. 4. Connect a suitable voltmeter (0-300V ac) across line to neutral of the generator. 5. Start generator set, and run on no load at nominal frequency e.g. 50-53Hz or 60-63Hz. 6. If the red Light Emitting Diode (LED) is illuminated, refer to the Under Frequency Roll Off (UFRO) adjustment. 7. Carefully turn VOLTS control clockwise until rated voltage is reached. 8. If instability is present at rated voltage, refer to stability adjustment, then re-adjust voltage if necessary. 9. Voltage adjustment is now completed. K1 K2 P2 P3 P4 XX X 3 2 2 1 A1 A2 S1 S2 1 2 3 4 5 6 7 8 C B A 50 C 60 SX440 Trim Droop Volts Stability Selection UFRO Frequency Selection Indicator LED Stability K1-K2 Power isolation link (normally fitted) Sensing links standard positions 60Hz 50Hz < 90kW 90-550kW > 550kW Note. If replacing an existing SX440, position the links and connections the same as the original SX440. If up grading to an SX440 refer to generator wiring diagram for connection details. Note. There are two terminals marked ‘2’ they are connected, either one or both can be used. Warning: Electrical shock can cause injury or death. Ensure that all personnel operating, servicing, maintaining or working near this equipment are fully aware of the emergency procedures in case of accidents. Before removing the protective covers to carry out service maintenance or repair, ensure that the engine is inhibited and the generator is electrically isolated. ww w. we llf ut .co m FITTING AND OPERATING TD_SX440 AVR_03.06_04_GB Barnack Road • Stamford • Lincolnshire • PE9 2NB Tel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100 © 2006 Cummins Generator Technologies Limited. Printed in England. STABILITY ADJUSTMENT The AVR includes a stability or damping circuit to provide good steady state and transient performance of the generator. The correct setting can be found by running the generator at no load and slowly turning the stability control anti- clockwise until the generator voltage starts to become unstable. The optimum or critically damped position is slightly clockwise from this point (i.e. where the machine volts are stable but close to the unstable region). OPTIMUM RESPONSE SELECTION The stability selection ‘jumper’ should be correctly linked, A-B, B-C or A-C at the bottom of the board for the frame size of the generator, (see drawing). UNDER FREQUENCY ROLL OFF (UFRO) ADJUSTMENT The AVR incorporates an underspeed protection circuit which gives a volts/Hz characteristic when the generator speed falls below a presettable threshold known as the "knee" point. The red Light Emitting Diode (LED) gives indication that the UFRO circuit is operating. The UFRO adjustment is preset and sealed and only requires the selection of 50 / 60Hz using the jumper link. For optimum setting, the LED should illuminate as the frequency falls just below nominal, i.e. 47Hz on a 50Hz system or 57Hz on a 60Hz system. DROOP ADJUSTMENT Generators intended for parallel operation are fitted with a quadrature droop C.T. which provides a power factor dependent signal for the AVR. The C.T. is connected to S1, S2 on the AVR. The DROOP adjustment is normally preset in the works to give 5% voltage droop at full load zero power factor. Clockwise increases the amount of C.T. signal injected into the AVR and increases the droop with lagging power factor (cos Ø). With the control fully anti-clockwise there is no droop. TRIM ADJUSTMENT An analogue input (A1 A2) is provided to connect to the Newage Power Factor Controller or other devices. It is designed to accept dc signals up to +/- 5 volts. CAUTION Any devices connected to this input must be fully floating and galvanically isolated from ground, with an insulation capability of 500 Vac. Failure to observe this could result in equipment damage. The dc signal applied to this input adds to the AVR sensing circuit. A1 is connected to the AVR 0 volts. Positive on A2 increases excitation. Negative on A2 decreases excitation. The TRIM control allows the user to adjust the sensitivity of the input. With TRIM fully anti-clockwise the externally applied signal has no effect. Clockwise it has maximum effect. Normal setting is fully clockwise when used with a Newage Power Factor Controller. Skill requirements of personnel Service and maintenance procedures should only be carried out by experienced, qualified, engineers/technicians, familiar with the procedures and the equipment. Before any intrusive procedures are carried out, ensure that the engine is inhibited and the generator is electrically isolated. ww w. we llf ut .co m
本文档为【SX440,STAMFORD,调压板英文说明书】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_183660
暂无简介~
格式:pdf
大小:106KB
软件:PDF阅读器
页数:4
分类:金融/投资/证券
上传时间:2011-11-30
浏览量:98