VITEKO宽电压多功能时间继电器VIMT51CW24 Specifications are subject to change without notice (11.01.07) 1 Description & Mode of operation: Multifunction Multi-voltage timer with 7 knob-selectable functions and 7 knob-selectable time ranges within 0.1s and 100h. For mounting on DIN-rail. Housing 1...

VITEKO宽电压多功能时间继电器VIMT51CW24
Specifications are subject to change without notice (11.01.07) 1 Description & Mode of operation: Multifunction Multi-voltage timer with 7 knob-selectable functions and 7 knob-selectable time ranges within 0.1s and 100h. For mounting on DIN-rail. Housing 17.5 mm wide suitable both for back and front panel mounting. Wide power supply range: 12 to 240 VAC/DC. Function Op - Delay on operate The time period begins as soon as the trigger contact is closed. At the end of the set delay time the relay operates and does not release until the trigger contact is closed again or the power supply is disconnected. If the trigger contact is closed before the end of the delay time, the device resets and a new time period starts. Function In - Interval The relay operates and the time period begins as soon as the trigger contact is closed. The relay releases at the end of this period or when the power supply is disconnected. The relay operates again when the trigger contact is closed again. If the trigger contact is closed before the end of the delay time, the device resets and a new time period starts. Function Io - Interval on trigger open The relay operates and the time period begins as soon as the trigger contact is opened. At the end of the set delay or when the power supply is disconnected the relay releases. The relay operates again when the trigger contact is opened again. If the trigger contact is opened before the end of the delay time the relay keeps ON and a new time period begins. Function Id - Double interval The relay operates and the time period begins as soon as the trigger contact is closed. The relay releases at the end of this period or when the power supply is disconnected. When the trigger contact is opened the relay operates again for the set delay period. If the trigger contact is opened before the end of the first time period the second one begins; if the trigger contact is closed before the end of the second time period the device resets and the first time peri- od begins again. FEATURES • Selectable time range 0.1 s to 100 h • 7 knob selectable functions: Op - delay on operate In - interval Io - interval on trigger open Id - double interval Dr - delay on release R - symmetrical recycler ON first Rb - symmetrical recycler OFF first • Automatic or manual start • Repeatability: ≤ 0.2% • Output: 5 A SPDT relay • For mounting on DIN-rail in accordance with DIN/EN 50 022 • 17.5 mm DIN-rail housing • Combined AC and DC power supply • LED indication for relay status and power supply ON Timer Type VIMT51CW24 Timers Function Dr - Delay on release The relay operates as soon as the trigger contact is closed. The time period begins when the trigger contact is opened. The relay releases at the end of the set delay time or when the power supply is disconnected. The relay operates again when the input contact is closed again. If it is opened before the end of the delay time the relay keeps ON, a new time period begins as soon as the contact is closed again. Function R - Symmetrical recycler, ON-time period first The relay operates and the time period begins as soon as the input contact is closed. After the set delay period the relay releases for the same time period. This sequence con- tinues with equal ON- and OFF-time periods until the power supply is interrupted. Function Rb - Symmetrical recycler, OFF-time period first The time period begins as soon as the input contact is closed. The relay is OFF during the set delay period, after this time it operates for the same time period. This sequence continues with equal OFF- and ON-time periods until the power supply is interrupted. Additional Load It's possible to wire an additional load (i.e. a relay) between pins Y1 and A2, driven by the trigger contact without dam- aging the device. Yellow LED working mode Timing: Slow blinking Relay ON: See operation diagrams Incorrect knobs position: Fast blinking QQ :2 49 76 31 99 1 2 Specifications are subject to change without notice (11.01.08) VIMT51 Power ON delay ≤ 100 ms Indication for Power supply ON LED, green Output relays ON LED, yellow (flashing when timing) Environment (EN 60529) Degree of protection IP 20 Pollution degree 2 (IEC 60664) Operating temperature -20° to +60°C, R.H. < 95% Storage temperature -30° to +80°C, R.H. < 95% Housing Dimensions 17.5 x 81 x 67.2 mm Material PA66 Note: on the Y1 terminal is mounted a flexible unipolar red cable (N07V-K, 1 mm2, 40 mm in lenght, unsheated sides) Weight 75 g Screw terminals Tightening torque Max. 0.5 Nm according to IEC EN 60947 CE Marking Yes EMC Electromagnetic Compatibillity Immunity According to EN 61000-6-2 Emissions According to EN 61000-6-3 General: Power supply Overvoltage cat. II Rated operational voltage (IEC 60664, IEC 60038) through terminals A1, A2: 12 to 240 VDC + 10% -15% and 12 to 240 VAC + 10% -15%, 45 to 65 Hz Voltage interruption ≤ 10 ms Rated operational power AC supply: 4 VA DC supply: 1.5 W Supply: Upper knob: Setting of function: Op- delay on operate In - interval Io - interval on trigger open Id - double interval Dr - delay on release R - symmetrical recycler (ON first) Rb - symmetrical recycler (OFF first) Centre knob: Time setting on relative scale: 1 to 10 with respect to the chosen range. Lower knob: Setting of time range Time Setting: Specifications Timing: Time ranges Knob selectable 0.1 to 1 s 1 to 10 s 6 to 60 s 60 to 600 s 0.1 to 1 h 1 to 10 h 10 to 100 h Setting accuracy ≤ 5% Repeatability ≤ 0.2% Time variation Within rated power supply ≤ 0.05%/V Within ambient temperature ≤ 0.2%/°C Reset Manual reset of time and/or Close the trigger contact relay between pins A1 and Y1 Pulse duration ≥ 100 ms Power supply interruption ≥ 200 ms Automatic start Connect pins A1 and Y1 Output 1xSPDT or relay Rated insulation voltage 250 VAC (rms) Contact Ratings (AgSnO2) µ Resistive loads AC 1 5 A @ 250 VAC DC 12 5 A @ 24 VDC Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC Mechanical life ≥ 30 x 106 operations Electrical life ≥ 105 operations (at 5 A, 250 V, cos ϕ = 1) Operating frequency < 7200 operations/h Dielectric strength Dielectric voltage 2 kVAC (rms) Rated impulse withstand voltage 2.5 kV (1.2/50 µs) Output: QQ :2 49 76 31 99 1 Specifications are subject to change without notice (11.01.07) 3 VIMT51 Operating Diagrams: Powersupply RelayON Triggerinput T T LED FunctionOp-Delayonoperate-Manualstart Powersupply RelayON T T LED FunctionOp-Delayonoperate-Automaticstart Powersupply RelayON Triggerinput T T LED FunctionIn-Interval-Manualstart Powersupply RelayON T LED FunctionIn-Interval-Automaticstart T ON OFF ON OFF ON OFF ON OFF FunctionIo-Intervalontriggeropen Powersupply RelayON Triggerinput T T LED FunctionId-Doubleinterval Powersupply RelayON Triggerinput T T LED ON OFF ON OFF FunctionDr-Delayonrelease Powersupply RelayON Triggerinput T LED Powersupply RelayON T T T T LED Triggerinput FunctionRb-Symmetricalrecycler(OFFfirst) Powersupply RelayON T T T T LED Triggerinput ON OFF ON OFF ON OFF Function R - Symmetrical recycler (ON first) QQ :2 49 76 31 99 1 4 Specifications are subject to change without notice (11.01.08) VIMT51 67.2 18.7 45 17.5 81 2 Dimensions:Wiring Diagram: QQ :2 49 76 31 99 1
本文档为【VITEKO宽电压多功能时间继电器VIMT51CW24】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: 免费 已有0 人下载
最新资料
资料动态
专题动态
is_744534
暂无简介~
格式:pdf
大小:306KB
软件:PDF阅读器
页数:4
分类:生产制造
上传时间:2012-02-26
浏览量:27