JEDEC
STANDARD
Test Method for Measuring Whisker
Growth on Tin and Tin Alloy Surface
Finishes
JESD22-A121A
(Revision of JESD22-A121.01, December 2005)
JULY 2008
JEDEC SOLID STATE TECHNOLOGY ASSOCIATION
NOTICE
JEDEC standards and publications contain material that has been prepared, reviewed, and approved
through the JEDEC Board of Directors level and subsequently reviewed and approved by the
JEDEC legal counsel.
JEDEC standards and publications are designed to serve the public interest through eliminating
misunderstandings between manufacturers and purchasers, facilitating interchangeability and
improvement of products, and assisting the purchaser in selecting and obtaining with minimum
delay the proper product for use by those other than JEDEC members, whether the standard is to be
used either domestically or internationally.
JEDEC standards and publications are adopted without regard to whether or not their adoption may
involve patents or articles, materials, or processes. By such action JEDEC does not assume any
liability to any patent owner, nor does it assume any obligation whatever to parties adopting the
JEDEC standards or publications.
The information included in JEDEC standards and publications represents a sound approach to
product specification and application, principally from the solid state device manufacturer
viewpoint. Within the JEDEC organization there are procedures whereby a JEDEC standard or
publication may be further processed and ultimately become an ANSI standard.
No claims to be in conformance with this standard may be made unless all requirements stated in
the standard are met.
Inquiries, comments, and suggestions relative to the content of this JEDEC standard or publication
should be addressed to JEDEC at the address below, or call (703) 907-7559 or www.jedec.org
Published by
©JEDEC Solid State Technology Association 2008
3103 North 10th Street
Suite 240 South
Arlington, VA 22201-2107
This document may be downloaded free of charge; however JEDEC retains the
copyright on this material. By downloading this file the individual agrees not to
charge for or resell the resulting material.
PRICE: Please refer to the current
Catalog of JEDEC Engineering Standards and Publications online at
http://www.jedec.org/Catalog/catalog.cfm
Printed in the U.S.A.
All rights reserved
PLEASE!
DON’T VIOLATE
THE
LAW!
This document is copyrighted by JEDEC and may not be
reproduced without permission.
Organizations may obtain permission to reproduce a limited number of copies
through entering into a license agreement. For information, contact:
JEDEC Solid State Technology Association
3103 North 10th Street
Suite 240 South
Arlington, Virginia 22201-2107
or call (703) 907-7559
JEDEC Standard No. 22-A121A
-i- Test method A121A
(Revision of A121.01)
TEST METHOD A121
Test Method For Measuring Whisker Growth On Tin And Tin Alloy Surface Finishes
Disclaimer
This document is not a qualification standard. It contains a suite of recommended tin whisker
growth tests. If these common tests are adopted, then the industry can collect common and
comparable data that may improve the understanding of the fundamentals of whisker growth and
allows comparisons between technologies. Tests in this document may be changed in the future as
a better understanding of the mechanisms causing tin whisker growth is developed.
Based on a variety of testing and data review from around the globe, three test conditions have
been identified that appear to be suitable for monitoring tin whisker growth. The three test
conditions include two isothermal conditions with controlled humidity and a thermal cycling
condition. However, these test conditions have not been correlated with longer environmental
exposures of components in service. Thus, there is at present no way to quantitatively predict
whisker lengths over long time periods based on the lengths measured in the short-term tests
described in this document. At the time of writing, the fundamental mechanisms of tin whisker
growth are not fully understood and acceleration factors have not been established. However until
such time that acceleration factors are determined all acceptance requirements for commercial tin
finishes are provided in JEDEC standard JESD201. Certain applications, e.g., military or
aerospace, may require additional and/or different tin whisker tests or evaluations.
Introduction
The predominant terminal finishes on electronic components have been Sn-Pb alloys. As the
industry moves toward Pb-free components and assembly processes, the predominant terminal
finish materials will be pure Sn and alloys of Sn, including Sn-Bi and Sn-Ag.
Pure Sn and Sn-based alloy electrodeposits and solder-dipped finishes may grow tin whiskers,
which could electrically short across component terminals or break off the component and degrade
the performance of electrical or mechanical parts.
JEDEC Standard No. 22-A121A
Test method A121A -ii-
(Revision of A121.01)
JEDEC Standard No. 22-A121A
Page 1
Test method A121A
(Revision of A121.01)
TEST METHOD A121
Test Method For Measuring Whisker Growth On Tin And Tin Alloy Surface Finishes
(From JEDEC Board ballot JCB-08-42, formulated under the cognizance of the JC-14.1
Subcommittee on Reliability Test Methods for Packaged Devices.)
1 Scope
The methodology presented in this document, see Annex A for process flow, is applicable for
studying tin whisker growth from finishes containing a predominance of tin (Sn). This test
method may not be sufficient for applications with special requirements, e.g., military or aerospace.
Additional requirements may be specified in the appropriate requirements document.
The purpose of this standard is to:
• Provide an industry-standardized suite of tests for measurement and comparison of whisker
propensity for different plating or finish chemistries and processes.
• Provide a consistent inspection protocol for tin whisker examination.
• Provide a standard reporting format.
2 Normative references
JESD22-A104, Standard for Temperature Cycling
IPC 7530, Guidelines for Temperature Profiling for Mass Soldering (Reflow & Wave) Processes
JESD201, Environmental Acceptance Requirements for Tin Whisker Susceptibility of Tin and Tin
Alloy Surface Finishes
JEDEC Standard No. 22-A121A
Page 2
Test method A121A
(Revision of A121.01)
3 Terms and definitions
3.1 surface corrosion: A localized corrosion of the silver-colored tin surface finish appearing
in an optical microscope as non-reflective dark spots ranging in size from about 25 microns on the
longest dimension to the entire terminal.
3.2 whisker: A spontaneous columnar or cylindrical filament, usually of monocrystalline metal,
emanating from the surface of a finish. (See Annex C for example pictures of tin whiskers.)
NOTE 1 For the purpose of this document, whiskers have the following characteristics:
• An aspect ratio (length/width) greater than 2
• Can be kinked, bent, or twisted
• Usually have a uniform cross-sectional shape
• Typically consist of a single columnar filament that rarely branches
• May have striations along the length of the column and/or rings around the circumference of the column
• Length of 10 microns or more. Features less than 10 microns may be deemed important for research
but are not considered significant for this test method.
NOTE 2 Whiskers are not to be confused with dendrites: fern-like growths on the surface of a material
which can be formed as a result of electromigration of an ionic species or produced during solidification. (See
Annex D for a picture of a typical solidification dendrite.)
3.3 whisker density: The number of whiskers per unit area on a single lead or coupon area.
3.4 whisker growth: Measurable changes in whisker length and/or whisker density after
exposure to a whisker test condition for a certain duration or number of cycles.
3.5 whisker length: The straight line distance from the point of emergence of the whisker to
the most distant point on the whisker (i.e., the radius of a sphere containing the whisker with its
center located at the point of emergence), see Figure 5
3.6 whisker test coupon: A piece of metal of specified size and shape that is plated or dipped
with a tin finish for the purpose of measuring the propensity for whisker formation and growth.
4 Apparatus
4.1 Temperature cycling chambers
Air to air temperature cycling chamber(s), capable of cycling from -55(+0/-10) °C to +85(+10/-0) °C
or from -40(+0/-10) °C to +85(+10/-0) °C. The temperature cycling chamber(s) must be able to
satisfy the cycle conditions defined in Table 4.
JEDEC Standard No. 22-A121A
Page 3
Test method A121A
(Revision of A121.01)
4 Apparatus (cont’d)
4.2 Temperature humidity chambers
Temperature–humidity (T&H) chambers capable of non-condensing 55 ±3 °C, 85 ±3% RH and 30
±2 °C, 60 ±3% RH environment.
NOTE 1 The elevated temperature–humidity condition of 55 ±3 °C, 85 ±3% RH is close to the
condensation point. If water condenses on the tin finish during environmental exposure, the condensed
moisture and resulting corrosion may affect the final test results. To prevent condensation in the T & H
chamber, the chamber dry-bulb temperature must exceed the wet-bulb temperature at all times by not less
than 2.4 °C (or equivalent for electronic sensors). Before opening of the chamber door for loading and
unloading, the chamber temperature and humidity should be ramped down sufficiently close to room ambient
(recommended within 10 °C and 10% RH) to prevent condensation on the test samples and chamber walls.
NOTE 2 During operation, condensation is most likely to occur on the T & H test chamber walls and
ceiling; therefore, it is recommended that the test samples be sufficiently shielded from any condensed water
that may drip from the chamber ceiling and/or walls onto the samples.
NOTE 3 When loading the test samples into the T & H test chamber, the sample temperature must be
sufficiently higher than the chamber ambient temperature to avoid condensation on the test samples. It is
recommended that the test samples and all sample trays or holders be preheated (to a temperature equal to
the test temperature of the T & H test chamber) in a dry-bake oven prior to loading them into the T & H test
chamber.
NOTE 4 Frequent wet-bulb maintenance is required for proper control of this test condition.
4.3 Optical stereomicroscope (Optional)
Optical stereomicroscope with adequate lighting capable of 50X to 150X magnification and capable
of detecting whiskers with a minimum length of 10 microns, per Annex B. If tin whiskers are
measured with an optical system, then the system must have a stage that is able to move in three
dimensions and rotate, such that whiskers can be positioned perpendicular to the viewing direction
for measurement.
4.4 Optical microscope (Optional)
Optical microscope with adequate lighting capable of 100X to 300X magnification and capable of
measuring whiskers with a minimum length of 10 microns, per Annex B. For tin whisker
measurements, the optical system must have a stage that is able to move in three dimensions and
rotate, such that whiskers can be positioned perpendicular to the viewing direction for
measurement.
4.5 Scanning electron microscope
Scanning electron microscope (SEM) capable of at least 250X magnification. An SEM fitted with
an X-ray detector is recommended for elemental identification.
4.6 Convection reflow oven (Optional)
A convection reflow system capable of achieving the reflow profiles of Table 3.
JEDEC Standard No. 22-A121A
Page 4
Test method A121A
(Revision of A121.01)
5 Sample requirements and optional preconditioning
For acceptance requirements of tin finishes for commercial use, the relevant test conditions, read
points, and durations are given in JEDEC standard JESD201. For evaluating the whisker
propensity of tin finishes for other purposes (e.g., scientific study, preliminary evaluations of various
platings, etc.), it is recommended that all three conditions defined in Table 4 be used and that the
durations given in JESD201, Table 4a for Class 1 and 2 products be used. In addition, each test
condition is to be performed independently on separate samples.
5.1 Acceptance requirements:
For acceptance requirements of tin finishes for commercial use: Use JEDEC standard JESD201 for
the following:
• Test conditions
• Test samples
• Read Points
• Durations
• Sample size
• Test sample preconditioning
• Reporting
NOTE Coupons are not acceptable for acceptance requirements.
5.2 Scientific studies
For evaluating the whisker propensity of tin finishes for other purposes (e.g., scientific study,
preliminary evaluations of various platings, etc.), it is recommended that all conditions defined in
JESD201 for Class 2 products are used. In addition, each test condition is to be performed
independently on separate samples. Test coupons may be used for scientific studies.
5.2.1 Test coupons
For comparison purposes, if using coupons, a total inspection area of at least 75 mm2 on at least 3
coupons is required for each test condition. For small coupons, it is recommended that there be
sufficient coupons so that the total area inspected adds up to a minimum of 75 mm2, as described
in Table 1.
JEDEC Standard No. 22-A121A
Page 5
Test method A121A
(Revision of A121.01)
5.2 Scientific studies (cont’d)
5.2.1 Test coupons (Cont’d)
Table 1 — Test Sample Size Requirements per Precondition Treatment for Coupons
Sample
Type
Finished
Area [1]
Minimum
Number of
Samples
Minimum Total
Inspection
Area for
Screening
Inspection
Minimum
Inspection
Surface Area
per Sample for
Screening
Inspection
Minimum Total
Number of
Inspection
Areas for
Screening
Inspection[2]
Detailed
Inspection
(Number of
areas per
Readpoint)[2]
Small
Coupons < 25 mm
2 3 75 mm2 Top and two sides of coupon
75 mm2 ÷
(Plated area on
top and 2 sides
of coupon)
9
Large
Coupons ≥ 25 mm
2 3 75 mm2
Top and two
sides up to a
total of 25 mm2
3 9
NOTE 1 See Figure 4 for detailed definition of the plated/finished area for inspection.
NOTE 2 Each area for detailed inspection shall be a minimum of 1.7mm2.
The same components or coupons evaluated for each test condition may be evaluated at all
sequential readouts, including the final readout. Hence, to study a single finish, a minimum of 9
coupon samples are required to complete the three test conditions. Alternatively, the test may be
started with a sufficient quantity of test samples equaling the minimum number of samples required
per readout times the number of readouts. If a more accurate determination of growth kinetics is
needed, it is recommended that the same test samples be used for each sequential readout
instead of using re-populated samples.
5.3 Optional test sample preconditioning
Table 2 lists optional test sample preconditioning treatments that are recommended prior to all
subsequent Sn whisker growth tests. If the test method described in this standard is used as part
of a tin finish acceptance evaluation, refer to JEDEC standard JESD201 for the required
precondition treatments.
JEDEC Standard No. 22-A121A
Page 6
Test method A121A
(Revision of A121.01)
5.3 Optional test sample preconditioning (cont’d)
Table 2 — Optional Preconditioning Treatments for Tin Whisker Test Samples
Condition
Preconditioning
Temperature
Exposure
Thermal Profile
Exposure Use Guidelines
A None Normal ambient exposure
Intended to test for whisker growth under
ambient temperature/humidity storage.
B
Room temperature
storage for a
minimum of 4
weeks after the
finish is applied
15 -30 °C
30 – 80% RH
Intended for samples without under-plating or
post bake mitigation before exposure to high
temperature/humidity storage, temperature
cycling or preconditioning per conditions C or D.
C
Sn-Pb
Temperature
Preconditioning
Sn-Pb profile per
Table 3
Intended to test for whisker growth after thermal
exposure to Sn-Pb SMT assembly temperatures
(backward compatibility).
D
Pb-free
Temperature
Preconditioning
Pb-free profile per
Table 3
Intended to test for whisker growth after thermal
exposure to Pb-free SMT assembly
temperatures (Pb-free compatibility).
5.3.1 Optional test sample preconditioning profiles
NOTE: J-STD-020 UTILIZES A PACKAGE TEMPERATURE REFERENCE; THE PROFILES
HEREIN UTILIZE A LEAD OR COUPON TEMPERATURE REFERENCE.
Test sample preconditioning profile information is shown in Table 3 and Figure 1. All profile criteria
reference either the lead or solder joint temperature for components or the surface temperature for
coupons. For the profile and the preconditioning process itself, it is recommended that non-
metallized carriers or printed circuit boards be used to hold the samples during the reflow process.
For components with leads, the orientation of the component shall be in the “live bug” configuration
(i.e., leads down touching the carrier or board).
JEDEC Standard No. 22-A121A
Page 7
Test method A121A
(Revision of A121.01)
5.3 Optional test sample preconditioning (cont’d)
5.3.1 Optional test sample preconditioning profiles (cont’d)
Table 3 — Optional Preconditioning Reflow Profiles [1]
Profile Feature Sn-Pb Profile Pb-Free Profile
Average ramp-up rate
(Tsmax to Tpeak)
3 °C/second max. 3 °C/second max.
Preheat:
- Temperature Min (Tsmin)
- Temperature Max (Tsmax)
- Time (Tsmin to Tsmax) (ts)
100 °C
150 °C
60–120 seconds
150 °C
200 °C
60–120 seconds
Time maintained above:
- Temperature (TL)
- Time (t L)
183 °C
60–120 seconds
217 °C
60–120 seconds
Lead or Solder Joint Temperature (Tpeak) 200–220 °C [2] 245–260 °C [3]
Average ramp-down Rate (Tpeak to Tsmax) 6 °C/second max. 6 °C/second max.
Time 25°C to Peak Temperature 6 minutes max. 8 minutes max.
NOTE 1 All temperatures refer to lead or solder joint temperature for components or the
surface temperature for coupons.
NOTE 2 Maximum temperature of 220 °C ensures that the finish is not melted
(i.e., melting point of pure Sn is 232 °C).
NOTE 3 Minimum temperature of 245 °C ensures that the finish is melted.
25
Time
Te
m
pe
ra
tu
re
Tpeak
T L tL
Time 25 oC to Peak
tS
Ts min
Preheat AreaTs max
Ramp Range
Figure 1 — Optional Preconditioning Reflow Profile
JEDEC Standard No. 22-A121A
Page 8
Test method A121A
(Revision of A121.01)
6 Whisker inspection, length measurement and test conditions
The whisker inspection procedure includes three parts: (1) the initial pre-test inspection, (2) the
screening inspection, and (3) the detailed inspection. The initial inspection should be performed
once before the test samples are exposed to any test condition. The screening inspection should
be performed at each readout. If whiskers are detected in the screening inspection, then the
detailed inspection should be performed at that readout. The whisker inspections can be
performed using either an SEM or a validated optical system meeting the conditions as outlined in
Annex B.
6.1 Handling
When handling test samples, care must be taken to avoid contact with the finish which may result
in the detachment of whiskers. For SEM inspection, a conduct
本文档为【JESD22A121A】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑,
图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。