暖通项目采暖热负荷详细计算表(内部)R1系统散热器计算最少3片最多25片立管编号层数热负荷热负荷(负荷汇总隐藏)供水温度回水温度室温附加系数散热量/片片数调整片数型号备注调整片数每层片数1~5118501850537275.050.05.0100%99.019.6220多柱钢管柱散热器GGZ3-III-600(3柱)19.6184173332201850006120002000537275.050.05.0105%99.021.2123多柱钢管柱散热器GGZ3-III-600(3柱)22.2695548106232000007120002000537...

暖通项目采暖热负荷详细计算表(内部)
R1系统散热器计算最少3片最多25片立管编号层数热负荷热负荷(负荷汇总隐藏)供水温度回水温度室温附加系数散热量/片片数调整片数型号备注调整片数每层片数1~5118501850537275.050.05.0100%99.019.6220多柱钢管柱散热器GGZ3-III-600(3柱)19.6184173332201850006120002000537275.050.05.0105%99.021.2123多柱钢管柱散热器GGZ3-III-600(3柱)22.2695548106232000007120002000537275.050.05.0105%99.021.2123多柱钢管柱散热器GGZ3-III-600(3柱)22.269554810623200000R1系统散热器计算最少3片最多25片立管编号层数热负荷热负荷(负荷汇总隐藏)供水温度回水温度室温附加系数散热量/片片数调整片数型号备注调整片数每层片数N117,833002000537275.068.218.0105%90.538.2841多柱钢管柱散热器GGZ3-III-600(3柱)40.1922970762251205013001300166915,626001300130068.262.818.0105%77.635.183736.9364308725191300193,426001300130062.857.420.0110%62.643.614847.97398053332413001300241,235501250125057.450.020.0110%50.274.218281.63088507332923002300532,37,839002500537275.068.118.0110%90.545.2550多柱钢管柱散热器GGZ3-III-600(3柱)49.7735179074321420014001400188145,641002100210068.160.918.0110%75.756.896362.574506003322000313,430001500150060.955.620.0110%59.153.325958.65571826633015001500301,232000055.650.020.0110%48.669.147676.0546162874032003200764,57,838802500537275.066.118.0110%88.446.1151多柱钢管柱散热器GGZ3-III-600(3柱)50.7218968777331093013801380186275,640002000200066.157.018.0110%69.660.356766.3861673381342000343,430501550155057.050.020.0110%49.964.237170.6508033573615001500351,200050.050.020.095%43.40.000000006,77,839002500537275.068.118.0110%90.445.2750多柱钢管柱散热器GGZ3-III-600(3柱)49.802242548321410014001400188085,640002000200068.161.018.0110%75.755.486161.0243967487312000313,430001500150061.055.720.0110%59.253.225958.54178872853015001500301,232000055.750.020.0110%48.669.097675.99590220030320032007687,839002500537275.068.318.0110%90.745.1450多柱钢管柱散热器GGZ3-III-600(3柱)49.6494510917321465014001400188405,640502000200068.361.418.0110%76.455.646261.2024008936312050313,430001500150061.456.320.0110%60.252.285857.51102124442915001500291,237001500150056.350.020.0110%49.278.908786.7951054906352200220052107,800537275.075.018.095%97.90.000多柱钢管柱散热器GGZ3-III-600(3柱)0042000002415,6100050050075.069.018.095%91.511.481110.9039465727650063,4120060060069.061.920.0100%73.517.141817.1381519035960060091,2200080080061.950.020.0105%54.638.494140.4121199591161200120025117,839002500537275.066.118.0110%88.346.3951多柱钢管柱散热器GGZ3-III-600(3柱)51.0266462069331090014001400186255,640002000200066.156.918.0110%69.460.506766.5468512602342000343,430001500150056.950.020.0110%49.863.297069.61851128973515001500351,200050.050.020.095%43.40.0000000013-157,839002500537275.068.118.0110%90.445.2750多柱钢管柱散热器GGZ3-III-600(3柱)49.802242548321410014001400188085,640002000200068.161.018.0110%75.755.486161.0243967487312000313,430001500150061.055.720.0110%59.253.225958.54178872853015001500301,232000055.750.020.0110%48.669.097675.995902200303200320076167,839002500537275.068.218.0110%90.645.1950多柱钢管柱散热器GGZ3-III-600(3柱)49.7090700969321443014001400188275,640002000200068.261.318.0110%76.255.126160.6286270424312000313,428301450145061.356.420.0110%60.249.345554.27327649882813801380271,237001500150056.450.020.0110%49.378.768786.6354817626352200220052177,836002200537275.067.618.0110%89.942.0447多柱钢管柱散热器GGZ3-III-600(3柱)46.2410184187291215014001400186975,624501200120067.662.618.0105%76.833.493635.1665789684181250183,427001400140062.657.020.0110%62.045.715150.2782771482613001300251,234001400140057.050.020.0110%49.971.577978.7289263603332000200046N21820002000537275.068.718.0105%91.123.0525多柱钢管柱散热器GGZ3-III-600(3柱)24.199180440625795000456740504050405068.756.018.0110%71.259.726665.6962106005660610001000100056.052.820.0105%51.620.352221.36815710362200590090090052.850.020.0105%46.020.552221.581118755122002,37,838802500537275.068.218.0110%90.545.0050多柱钢管柱散热器GGZ3-III-600(3柱)49.5032713653321418013801380188135,641002000200068.260.918.0110%75.756.856362.5395583165312100323,430001500150060.955.620.0110%59.153.305958.6330293453015001500301,232000055.650.020.0110%48.669.137676.04293326032003200764,57,8163002500537275.059.318.0110%81.1211.00232多柱钢管柱散热器GGZ3-III-600(3柱)232.09615800913625920138001380019614865,639201960196059.355.518.0110%61.367.197473.9045233368371960373,432001600160055.552.420.0110%50.766.217372.83583034183716001600371,225000052.450.020.0110%45.657.586463.33762312202500250006,77,841002600537275.067.918.0110%90.347.6953多柱钢管柱散热器GGZ3-III-600(3柱)52.4610767722341447015001500198305,638901890189067.961.218.0110%75.753.936059.3187747151292000313,431801600160061.255.720.0110%59.456.206261.81848780953115801580311,233000055.750.020.0110%48.771.217978.3288584196033003300798,97,834802100537275.068.118.0110%90.540.3945多柱钢管柱散热器GGZ3-III-600(3柱)44.4278284907271262013801380187245,627001300130068.162.818.0105%77.636.553938.3822861303191400203,426601360136062.857.520.0110%62.744.534948.98705091512513001300241,237801580158057.550.020.0110%50.378.848786.7187183952362200220051107,800537275.075.018.095%97.90.000多柱钢管柱散热器GGZ3-III-600(3柱)0042000002415,6100050050075.069.018.095%91.511.481110.9039465727650063,4120060060069.061.920.0100%73.517.141817.1381519035960060091,2200080080061.950.020.0105%54.638.494140.4121199591161200120025117,835802100537275.067.618.0110%89.941.8246多柱钢管柱散热器GGZ3-III-600(3柱)46.005218038271202014801480196895,628501400140067.661.618.0105%75.839.474241.4455870658211450213,427601460146061.655.920.0110%60.048.295453.11375076822913001300251,228301680168055.950.020.0110%48.860.856766.9342233512401150115027127,835202000537275.068.418.0110%90.840.7145多柱钢管柱散热器GGZ3-III-600(3柱)44.775569608261336015201520197665,630401520152068.462.718.0110%77.841.014645.1080877038231520233,430701520152062.757.020.0110%62.251.845757.02538572252815501550291,237301680168057.050.020.0110%49.978.548786.396600535239205020504813-167,834801980537275.068.518.0110%90.940.2045多柱钢管柱散热器GGZ3-III-600(3柱)44.2250992818261337015001500197675,629301480148068.563.018.0105%78.239.334241.2961379004211450213,432801580158063.056.920.0110%62.455.226160.74142392172917001700321,236801680168056.950.020.0110%49.877.638685.3981512504392000200047177,834502050537275.068.018.0110%90.340.1145多柱钢管柱散热器GGZ3-III-600(3柱)44.1186532351271226014001400187035,623501300130068.063.218.0105%77.831.703433.2846965095191050153,427101360136063.257.620.0110%63.344.965049.45840881282513501350251,237501600160057.650.020.0110%50.577.988685.774427691372150215049第&P页,共&N页R2系统散热器计算最少3片最多25片立管编号层数热负荷热负荷(负荷汇总隐藏)供水温度回水温度室温附加系数散热量/片片数调整片数型号备注调整片数每层片数1-6,17-204层00075.075.018.095%97.90.000多柱钢管柱散热器GGZ3-III-600(3柱)000.006510000.003733层20002000200075.067.318.0105%89.623.432524.60170736352525.0000.002层20002000200067.359.618.0105%73.528.563029.98919487123030.0000.001层25102510251059.650.018.0110%56.246.865251.54946678845252.000.0074层22002200220075.066.118.0105%88.426.1428多柱钢管柱散热器GGZ3-III-600(3柱)27.45135055452828.006200000.003553层20002000200066.158.118.0105%70.729.703231.18729976033232.0000.002层20002000200058.150.018.0105%54.738.384140.29846862154141.0000.001层00050.050.018.095%47.10.000000.000.008,22,264层0075.075.018.095%97.90.000多柱钢管柱散热器GGZ3-III-600(3柱)000.003700000.002123层10001000100075.068.218.095%90.611.591111.00783603541111.0000.002层12001200120068.260.118.0100%75.016.801716.80313403351717.0000.001层15001500150060.150.018.0105%56.727.773029.15666157453030.000.00214层22002200220075.067.418.0105%89.725.7627多柱钢管柱散热器GGZ3-III-600(3柱)27.04844627662727.007200000.004133层15001500150067.462.218.0105%76.220.682221.71483652252222.0000.002层15001500150062.256.918.0105%65.624.022625.22569156672626.0000.001层20002000200056.950.018.0105%53.639.154241.10755579444242.000.0023-254层22002200220075.068.718.0105%91.125.3627多柱钢管柱散热器GGZ3-III-600(3柱)26.6270265012727.008710000.004993层20002000200068.762.918.0105%78.426.802928.14241249742929.0000.002层20002000200062.957.218.0105%66.631.533433.10154794743434.0000.001层25102510251057.250.018.0110%53.948.915453.79641380755454.000.0027,284层22002200220075.068.718.0105%91.125.3627多柱钢管柱散热器GGZ3-III-600(3柱)26.6270265012727.008710000.004993层20002000200068.762.918.0105%78.426.802928.14241249742929.0000.002层20002000200062.957.218.0105%66.631.533433.10154794743434.0000.001层25102510251057.250.018.0110%53.948.915453.79641380755454.000.00304层22002200220075.067.618.0105%89.925.702726.98196579932727.007400000.004243层20002000200067.660.818.0105%75.028.013029.40548455873030.0000.002层20002000200060.854.118.0105%61.434.233635.94114035853636.0000.001层12001200120054.150.018.0105%50.924.762626.00139307692626.000.00314层22002200220075.066.118.0105%88.426.142827.45135055452828.006200000.003553层20002000200066.158.118.0105%70.729.703231.18729976033232.0000.002层20002000200058.150.018.0105%54.738.384140.29846862154141.0000.001层00050.050.018.095%47.10.000000.000.009-16,29,33-364层22002200220075.068.718.0105%91.125.362726.6270265012727.008710000.004993层20002000200068.762.918.0105%78.426.802928.14241249742929.0000.002层20002000200062.957.218.0105%66.631.533433.10154794743434.0000.001层25102510251057.250.018.0110%53.948.915453.79641380755454.000.00324层13001300130075.070.818.0100%93.414.611514.61311252011515.007810000.004483层20002000200070.864.418.0105%82.225.562726.83772309032727.0000.002层20002000200064.458.018.0105%69.030.453231.97770101983232.0000.001层25102510251058.050.018.0110%54.748.195353.01084291145353.000.00第&P页共&N页长阳3-3热负荷计算房间名称维护结构名称计算传热系数传热系数面积室内温度室外温度附加系数耗热量考虑间歇调节x1.2负荷统计总负荷热指标一层北外墙0.60.6108.0018-10.60%1853产品展示区(左)北外窗2.862.8625.2018-10.60%2061窗缝79.8018-10.632561南外墙0.420.42113.4018-10.6-25%1022南外窗2.862.8621.6018-10.6-25%1325窗缝66.6018-10.621425南外门3312.4218-10.6-25%799门缝21.9018-10.64937门冷风侵入3312.4218-10.665%693通风6750.0018-10.60.1259027屋面0.600.60500.0018-10.60地面0.470.47500.0018-10.606721284253411034110试验室主厂房热指标68.2192790822一层北外墙0.60.655.4418-10.60%951产品展览区北外窗2.862.8616.5618-10.60%1355窗缝45.6018-10.631464南外墙0.420.42101.8818-10.6-25%918南外窗2.862.8633.1218-10.6-25%2032窗缝98.4018-10.622106南外门3332.2018-10.6-25%2072门缝29.1018-10.641245门冷风侵入3332.2018-10.665%1796通风8397.0018-10.60.12511230屋面0.600.60622.0018-10.60地面0.470.47622.0018-10.608361335284023440234试验室主厂房热指标64.6849190585一层北外墙0.60.666.9618-10.60%1149加工间北外窗2.862.8616.5618-10.60%1355窗缝45.6018-10.631464北外门336.4818-10.60%556门缝15.9018-10.661021门冷风侵入336.4818-10.665%361通风1836.0018-10.60.1252455屋面0.600.60153.0018-10.60地面0.470.47153.0018-10.602057104171250112501试验室主厂房热指标81.7032094871一层北外墙0.60.655.0818-10.60%945产品展示(右)北外窗2.862.8612.4218-10.60%1016窗缝34.2018-10.631098南外墙0.420.4229.7918-10.6-25%268南外窗2.862.8627.0018-10.6-25%1656窗缝36.9018-10.62790南外门336.2118-10.6-25%400门缝15.9018-10.64680门冷风侵入336.2118-10.665%346通风3145.5018-10.60.1254207屋面0.600.60233.0018-10.60地面0.470.47233.0018-10.603132145381744617446试验室主厂房热指标74.8739893803一层北外墙0.60.620.7016-10.60%330卫生间北外窗2.862.865.4016-10.60%411窗缝19.8016-10.63591通风348.0016-10.60.125433屋面0.600.6029.0016-10.60地面0.470.4729.0016-10.60363212825532553试验室主厂房热指标88.0406785324一层南外墙0.420.42114.3016-10.6-25%958门厅南外窗2.862.8620.7016-10.6-25%1181窗缝77.4016-10.621540南外门3312.4216-10.6-25%743门缝21.9016-10.64872门冷风侵入3312.4216-10.665%644通风3618.0016-10.60.1254500屋面0.600.60268.0016-10.60地面0.470.47268.0016-10.603351137891654716547试验室主厂房热指标61.7419355606一层北外墙0.60.653.4018-10.60%916楼梯间北外窗2.862.8621.6018-10.60%1767窗缝68.4018-10.632195通风276.0018-10.60.125369屋面0.600.6023.0018-10.60地面0.470.4723.0018-10.60309555766686668试验室主厂房热指标289.9189102748二层北外墙0.60.6108.0018-10.60%1853展示区北外窗2.862.8625.2018-10.60%2061窗缝79.8018-10.632561南外墙0.420.42113.4018-10.6-25%1022南外窗2.862.8621.6018-10.6-25%1325窗缝66.6018-10.621425南外门3312.4218-10.6-25%799门缝21.9018-10.64937门冷风侵入3312.4218-10.665%693通风6750.0018-10.60.1259027屋面0.600.60500.0018-10.60地面0.470.47500.0018-10.60217042604426044试验室主厂房热指标52.0888790822二层南外墙0.420.4278.6618-10.6-25%709公共食堂(小)南外窗2.862.8624.8418-10.6-25%1524窗缝73.8018-10.621579通风4194.0018-10.60.1255609屋面0.600.60233.0018-10.60地面0.470.47233.0018-10.603132125521506315063试验室主厂房热指标64.6475894565二层北外墙0.60.6129.2418-10.60%2218公共食堂(大)北外窗2.862.8637.2618-10.60%3048窗缝45.6018-10.631464通风4160.0018-10.60.1255563屋面0.600.60260.0018-10.60地面0.470.47260.0018-10.603495157871894518945试验室主厂房热指标72.864441408二层东外墙0.420.4212.6018-10.6-10%136休息区南外窗2.862.8627.0018-10.6-25%1656窗缝36.9018-10.62790通风837.0018-10.60.1251119屋面0.600.6062.0018-10.60地面0.470.4762.0018-10.60370144424442试验室主厂房热指标71.6419061884二层南外墙0.420.4225.8320-10.6-25%249办公室(右下)南外窗2.862.863.4220-10.6-25%224窗缝11.1020-10.62254通风688.5020-10.60.125985屋面0.600.6051.0020-10.60地面0.470.4751.0020-10.60171320552055试验室主厂房热指标40.29925392二层南外墙0.420.4227.7220-10.6-25%267VIP包间(共3间)南外窗2.862.868.2820-10.6-25%543窗缝24.6020-10.62563通风783.0020-10.60.1251120屋面0.600.6058.0020-10.60地面0.470.4758.0020-10.60249429932993试验室主厂房热指标51.6043988193二层北外墙0.420.4227.7220-10.60%356办公室(右上)北外窗2.862.868.2820-10.60%725备件室窗缝24.6020-10.62563接待室通风783.0020-10.60.1251120屋面0.600.6058.0020-10.60地面0.470.4758.0020-10.60276433173317试验室主厂房热指标57.1952087503二层北外墙0.420.4213.8620-10.60%178风机房北外窗2.862.864.1420-10.60%362配餐间窗缝12.3020-10.62282办公室小通风378.0020-10.60.125541屋面0.600.6028.0020-10.60地面0.470.4728.0020-10.60136316351635试验室主厂房热指标58.4100423771二层北外墙0.60.611.1616-10.60%178卫生间北外窗2.862.864.1416-10.60%315窗缝12.3016-10.63367通风324.0016-10.60.125403屋面0.600.6027.0016-10.60地面0.470.4727.0016-10.60126315161516试验室主厂房热指标56.14396032二层南外墙0.420.4213.5020-10.6-25%130值班室南外窗2.862.862.7020-10.6-25%177窗缝9.9020-10.62227通风351.0020-10.60.125502屋面0.600.6026.0020-10.60地面0.470.4726.0020-10.60103612431243试验室主厂房热指标47.82574368二层北外墙0.60.65.9516-10.60%95电梯厅北外窗2.862.864.0516-10.60%308窗缝13.5016-10.63403通风162.0016-10.60.125201屋面0.600.6018.0016-10.60地面0.470.4718.0016-10.60225123314791479试验室主厂房热指标82.1733584三层北外墙0.60.626.1020-10.60%479大办公室(上)北外窗2.862.867.2020-10.60%630共10间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.60地面0.470.4756.0020-10.60285434253425试验室主厂房热指标61.1530893257三层北外墙0.60.613.8620-10.60%254小办公室(上)北外窗2.862.864.1420-10.60%362共7间窗缝12.3020-10.63422通风372.0020-10.60.125532屋面0.600.6031.0020-10.60地面0.470.4731.0020-10.60157118861886试验室主厂房热指标60.8304372852三层南外墙0.60.626.1020-10.6-25%359大办公室(下)南外窗2.862.867.2020-10.6-25%473共7间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.60地面0.470.4756.0020-10.60257630923092试验室主厂房热指标55.2103507543三层南外墙0.60.613.8620-10.6-25%191小办公室(下)南外窗2.862.864.1420-10.6-25%272共10间窗缝12.3020-10.63422通风372.0020-10.60.125532屋面0.600.6031.0020-10.60地面0.470.4731.0020-10.60141717011701试验室主厂房热指标54.8615420594三层南外墙0.60.638.7020-10.6-25%533科技服务中心南外窗2.862.8610.8020-10.6-25%709窗缝34.2020-10.631174通风972.0020-10.60.1251391屋面0.600.6081.0020-10.60地面0.470.4781.0020-10.60380745684568试验室主厂房热指标56.40025536三层东外墙0.420.4212.6018-10.6-10%136休息区南外窗2.862.8627.0018-10.6-25%1656窗缝36.9018-10.62790通风837.0018-10.60.1251119屋面0.600.6062.0018-10.60地面0.470.4762.0018-10.60370144424442试验室主厂房热指标71.6419061884三层北外墙0.60.611.1616-10.60%178卫生间北外窗2.862.864.1416-10.60%315窗缝12.3016-10.63367通风324.0016-10.60.125403屋面0.600.6027.0016-10.60地面0.470.4727.0016-10.60126315161516试验室主厂房热指标56.14396032三层北外墙0.60.65.9516-10.60%95电梯厅北外窗2.862.864.0516-10.60%308窗缝13.5016-10.63403通风162.0016-10.60.125201屋面0.600.6018.0016-10.60地面0.470.4718.0016-10.60225123314791479试验室主厂房热指标82.1733584四层左侧北外墙0.60.626.1020-10.60%479大办公室(上)北外窗2.862.867.2020-10.60%630共4间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.60地面0.470.4756.0020-10.60285434253425试验室主厂房热指标61.1530893257四层左侧北外墙0.60.613.8620-10.60%254小办公室(上)北外窗2.862.864.1420-10.60%362共5间窗缝12.3020-10.63422通风372.0020-10.60.125532屋面0.600.6031.0020-10.60地面0.470.4731.0020-10.60157118861886试验室主厂房热指标60.8304372852四层右侧北外墙0.60.613.8620-10.60%254小办公室(上)北外窗2.862.864.1420-10.60%362共5间窗缝12.3020-10.63422通风372.0020-10.60.125532屋面0.600.6031.0020-10.60569地面0.470.4731.0020-10.60214125692569试验室主厂房热指标82.8624372852四层左侧南外墙0.60.626.1020-10.6-25%359大办公室(下)南外窗2.862.867.2020-10.6-25%473共14间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.60地面0.470.4756.0020-10.60257630923092试验室主厂房热指标55.2103507543四层右侧南外墙0.60.626.1020-10.6-25%359大办公室(下)南外窗2.862.867.2020-10.6-25%473共5间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.601028地面0.470.4756.0020-10.60360543264326试验室主厂房热指标77.2423507543四层右侧南外墙0.60.614.8020-10.6-25%204小办公室(下)南外窗2.862.863.2020-10.6-25%210共5间窗缝11.4020-10.63391通风336.0020-10.60.125481屋面0.600.6028.0020-10.60514地面0.470.4728.0020-10.60180021602160试验室主厂房热指标77.14989504四层东外墙0.420.4212.6018-10.6-10%136休息区南外窗2.862.8627.0018-10.6-25%1656窗缝36.9018-10.62790通风837.0018-10.60.1251119屋面0.600.6062.0018-10.601064地面0.470.4762.0018-10.60476557195719试验室主厂房热指标92.2339061884四层右侧北外墙0.60.611.1616-10.60%178卫生间北外窗2.862.864.1416-10.60%315窗缝12.3016-10.63367通风324.0016-10.60.125403屋面0.600.6027.0016-10.60431地面0.470.4727.0016-10.60169420332033试验室主厂房热指标75.29596032四层左侧北外墙0.60.65.9516-10.60%95电梯厅北外窗2.862.864.0516-10.60%308窗缝13.5016-10.63403通风162.0016-10.60.125201屋面0.600.6018.0016-10.60地面0.470.4718.0016-10.60100812091209试验室主厂房热指标67.1709584五层北外墙0.60.626.1020-10.60%479 培训 焊锡培训资料ppt免费下载焊接培训教程 ppt 下载特设培训下载班长管理培训下载培训时间表下载 室北外窗2.862.867.2020-10.60%630共4间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.60地面0.470.4756.0020-10.60285434253425试验室主厂房热指标61.1530893257五层北外墙0.60.613.8620-10.60%254小会议室北外窗2.862.864.1420-10.60%362共3间窗缝12.3020-10.63422通风372.0020-10.60.125532屋面0.600.6031.0020-10.60地面0.470.4731.0020-10.60157118861886试验室主厂房热指标60.8304372852五层南外墙0.60.6215.9120-10.6-25%2973众创服务平台南外窗2.862.8651.8420-10.6-25%3403窗缝172.8020-10.635934通风9600.0020-10.60.12513736屋面0.600.60600.0020-10.60地面0.470.47600.0020-10.60260463125531255试验室主厂房热指标52.0919327664六层北外墙0.60.626.1020-10.60%479培训室北外窗2.862.867.2020-10.60%630共4间窗缝22.8020-10.63783通风672.0020-10.60.125962屋面0.600.6056.0020-10.60地面0.470.4756.0020-10.60285434253425试验室主厂房热指标61.1530893257六层北外墙0.60.613.8620-10.60%254小会议室北外窗2.862.864.1420-10.60%362共3间窗缝12.3020-10.63422通风372.0020-10.60.125532屋面0.600.6031.0020-10.60地面0.470.4731.0020-10.60157118861886试验室主厂房热指标60.8304372852六层南外墙0.60.6215.9120-10.6-25%2973众创服务平台南外窗2.862.8651.8420-10.6-25%3403窗缝172.8020-10.635934通风9600.0020-10.60.12513736屋面0.600.60600.0020-10.60地面0.470.47600.0020-10.60260463125531255试验室主厂房热指标52.0919327664七层北外墙0.60.613.0520-10.60%240国际交流中心(上)北外窗2.862.863.6020-10.60%315共13间窗缝11.4020-10.63391通风252.0020-10.60.125361屋面0.600.6021.0020-10.60地面0.470.4721.0020-10.60130715681568试验室主厂房热指标74.6693436343七层南外墙0.60.613.4120-10.6-25%185国际交流中心(下)南外窗2.862.863.2420-10.6-25%213共16间窗缝10.8020-10.63371通风252.0020-10.60.125361屋面0.600.6021.0020-10.60地面0.470.4721.0020-10.60112913551355试验室主厂房热指标64.50132384七层北外墙0.60.65.9516-10.60%95电梯厅北外窗2.862.864.0516-10.60%308窗缝13.5016-10.63403通风162.0016-10.60.125201屋面0.600.6018.0016-10.60地面0.470.4718.0016-10.60100812091209试验室主厂房热指标67.1709584八层北外墙0.60.6170.5518-10.60%2927休息区北外窗2.862.8629.7018-10.60%2429窗缝108.9018-10.633495通风1440.0018-10.60.1251926屋面0.600.60160.0018-10.602746地面0.470.47160.0018-10.60135231622716227试验室主厂房热指标101.419533072八层南外墙0.60.6109.0820-10.6-25%1502综合会议厅南外窗2.862.8625.9220-10.6-25%1701窗缝86.4020-10.632967通风6480.0020-10.60.1259272屋面0.600.60405.0020-10.607436地面0.470.47405.0020-10.60228782745427454试验室主厂房热指标67.787000064八层南外墙0.60.628.6216-10.6-25%343会议前厅南外窗2.862.866.4816-10.6-25%370窗缝21.6016-10.63645西外墙0.60.626.3616-10.6-10%379西外窗2.862.863.2416-10.6-10%222窗缝10.8016-10.62215通风960.0016-10.60.1251194屋面0.600.6080.0016-10.601277地面0.470.4780.0016-10.60464355725572试验室主厂房热指标69.650585928八层南外墙0.60.626.8220-10.6-25%369贵宾休息室南外窗2.862.866.4820-10.6-25%425窗缝21.6020-10.63742通风472.5020-10.60.125676屋面0.600.6045.0020-10.60826地面0.470.4745.0020-10.60303936463646试验室主厂房热指标81.031316544八层南外墙0.60.626.8216-10.6-25%321戊类库房南外窗2.862.866.4816-10.6-25%370窗缝21.6016-10.63645东外墙0.60.633.3016-10.6-10%478通风720.0016-10.60.125896屋面0.600.6060.0016-10.60958地面0.470.4760.0016-10.60366744004400试验室主厂房热指标73.340553888八层北外墙0.60.65.9516-10.60%95电梯厅北外窗2.862.864.0516-10.60%308窗缝13.5016-10.63403通风162.0016-10.60.125201屋面0.600.6018.0016-10.60287地面0.470.4718.0016-10.60129515541554试验室主厂房热指标86.3229584八层北外墙0.60.611.1616-10.60%178卫生间北外窗2.862.864.1416-10.60%315窗缝12.3016-10.63367通风324.0016-10.60.125403屋面0.600.6027.0016-10.60431地面0.470.4727.0016-10.60169420332033试验室主厂房热指标75.29596032八层北外墙0.60.67.3018-10.60%125会服厅北外窗2.862.862.7018-10.60%221窗缝10.5018-10.63337通风216.0018-10.60.125289屋面0.600.6024.0018-10.60412地面0.470.4724.0018-10.60138416611661试验室主厂房热指标69.1915224地下消防泵房通风4320.005-10.60.1253151屋面0.600.60480.005-10.60地面0.470.47480.005-10.604493764491739173试验室主厂房热指标19.1101248二、三层北外墙0.60.6104.4020-10.60%1917北外窗2.862.8628.8020-10.60%2520窗缝91.2020-10.633132南外墙0.420.42106.2020-10.6-25%1024南外窗2.862.8628.8020-10.6-25%1890窗缝88.8020-10.622033通风6750.0020-10.60.1
本文档为【暖通项目采暖热负荷详细计算表(内部)】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
该文档来自用户分享,如有侵权行为请发邮件ishare@vip.sina.com联系网站客服,我们会及时删除。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。
本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。
网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。
下载需要: ¥16.9 已有0 人下载
最新资料
资料动态
专题动态
个人认证用户
丹丹陪你去流浪
暂无简介~
格式:xls
大小:347KB
软件:Excel
页数:0
分类:高中物理
上传时间:2021-09-22
浏览量:31