Brocade 815 HBA卡直连 VNX存储
黎旭祥 QQ:2668550
关于 FC拓扑-引自维基百科
http://en.wikipedia.org/wiki/Fibre_Channel
• Point-to-point (FC-P2P). Two devices are connected directly to each other. This is the
simplest topology, with limited connectivity.[1]
• Arbitrated loop (FC-AL). In this design, all devices are in a loop or ring, similar to token
ring networking. Adding or removing a device from the loop causes all activity on the loop
to be interrupted. The failure of one device causes a break in the ring. Fibre Channel hubs
exist to connect multiple devices together and may bypass failed ports. A loop may also
be made by cabling each port to the next in a ring.
• A minimal loop containing only two ports, while appearing to be similar to FC-P2P,
differs considerably in terms of the protocol.
• Only one pair of ports can communicate concurrently on a loop.
• Maximum speed of 8GFC.
• Switched fabric (FC-SW). All devices or loops of devices are connected to Fibre Channel
switches, similar conceptually to modern Ethernetimplementations. Advantages of this
topology over FC-P2P or FC-AL include:
• The switches manage the state of the fabric, providing optimized interconnections.
• The traffic between two ports flows through the switches only, it is not transmitted to
any other port.
• Failure of a port is isolated and should not affect operation of other ports.
• Multiple pairs of ports may communicate simultaneously in a fabric.
Brocade HBA卡 Director问
题
快递公司问题件快递公司问题件货款处理关于圆的周长面积重点题型关于解方程组的题及答案关于南海问题
在部署虚拟化测试环境中发现 Brocade的 HBA卡直连 EMC VNX5100存储,发
现两者无法互相发现:
刚开始怀疑是存储的问题,但问了不少人都说 Brocade 的 HBA 卡不支持直
连,VNX是支持直连的,而且 VNX上的前端 FC 端口也显示到速率,证明物理层连
接是没问题的,Google一番,发现出现不少这种情况,都显示Brocade的卡不支持
直连( only FCSW),必须带交换机,后来 Google发现,新版本的 BCU3.2.1支持直
连(也就支持 FCAL,P2P),于是立刻更新 ESXI 的 Brocade HBA卡驱动,最新版的
Driver请在 Brocade官网下载
brocade_driver_esx5x_v3-2-1-0.tar
通过 SCP或 vsphere client上传到 ESXI的目录下,例如:
通过 vsphere client上传到 local datastore1/brocade
执行如下命令:
cd /vmfs/volumes/datastore1/Brocade
tar –zxh brocade_driver_esx5x_v3-2-1-0.tar
./brocade_install_esxi.sh
然后会引导安装最新的 3.2.1驱动与 BCU
安装完成后 reboot esxi
reboot之后 cd /opt/brocade/bin 执行 bcu
执行 1/0端口 拓扑改为 FCAL loop, disable->enable
然后登陆存储查看是否能识别到,OK,顺带把主机注册
OK,存储已经发现主机,然后分配 LUN给主机,主机 rescan,也没问题